8-Channel 0.5-10 μL Autoclavable Manual Pipette ATOMFAIR®

$300.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette 8-channel manual pipette with 0.5-10 µL range, 0.01 µL increments, and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HIPP-E050-08CH
Category: ,
Tags:
Brands:

Description

HiPette 8-channel 0.5-10 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette 8-channel 0.5-10 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 0.5-10 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 0.5-10 µL working range, 0.01 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 0.5-10 µL with 0.01 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-8CHANNEL-0-5-10-µL
Product Family HiPette
Channel count 8-channel
Volume range 0.5-10 µL
Increment 0.01 µL
Test volume(s) 10 / 5 / 1 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy. Only compatible tips should be used to ensure proper sealing and volume delivery.

  • Calibration: The pipette must be calibrated according to ISO 8655-2 using the test volumes of 10, 5, and 1 µL.
  • Tip Compatibility: Only use tips designed for 0.5-10 µL range and 8-channel pipettes to ensure proper sealing.
  • Sterilization: The pipette is fully autoclavable; allow it to cool and dry completely before reassembly.
  • Volume Range: Do not operate below 0.5 µL or above 10 µL to maintain accuracy.
  • Increment: The volume adjustment increment is 0.01 µL; avoid forcing the adjustment knob beyond limits.

This procedure describes the correct use of the HiPette 8-channel pipette for routine liquid transfer. Follow these steps to ensure accurate volume delivery and prevent cross-contamination.

Required Equipment: HiPette 8-channel 0.5-10 µL Pipette

  1. Set volume
    Set the volume to the desired value using the adjustment knob.
  2. Attach tips
    Attach compatible tips firmly to each channel.
  3. Aspirate liquid
    Aspirate liquid by depressing the plunger to the first stop, immersing tips, and releasing slowly.
  4. Dispense liquid
    Dispense liquid by depressing to the first stop, then to the second stop to expel any remaining liquid.
  5. Eject tips
    Eject the tips using the tip ejector button.

How does the systematic error of the HiPette 8-channel 0.5-10 µL pipette vary across its test volumes?

The systematic error is specified for each test volume (10, 5, and 1 µL) in the technical table, allowing calibration verification per ISO 8655-2. The pipette is designed for accurate microliter liquid handling, but exact error values should be referenced from the product's calibration certificate or technical documentation for method setup.

What tip compatibility should be confirmed for the HiPette 8-channel 0.5-10 µL pipette?

The pipette requires compatible 8-channel tips for the 0.5-10 µL range. The product description advises confirming compatible tips before ordering, and contact Atomfair technical sales for accessory matching.

What are the sterilization requirements for the HiPette 8-channel pipette?

The pipette is fully autoclavable, allowing complete sterilization for contamination-sensitive workflows. The source does not specify temperature or cycle parameters, so standard autoclave protocols for manual pipettes should be followed, and it is recommended to consult the user manual or manufacturer for specific cycle recommendations.

The HiPette 8-channel 0.5-10 µL pipette is a fully autoclavable manual pipette designed for high-throughput microplate and PCR workflows, offering a 0.01 µL increment and ISO 8655-2 calibration reference, but its multichannel format requires careful tip compatibility and calibration planning for each test volume.

Positive

  • Fully autoclavable for sterilization: The entire pipette can be autoclaved, enabling decontamination between uses in sensitive workflows such as PCR and cell culture without disassembly.
  • 8-channel parallel liquid handling: The 8-channel configuration supports efficient microplate loading, PCR plate preparation, and ELISA workflows, reducing operator time and improving repeatability in parallel reagent transfer.

Trade-offs

  • Tip compatibility required: The pipette requires confirmation of compatible tips before ordering, as multichannel pipettes are sensitive to tip fit and seal quality, which directly affect accuracy and precision.
  • Calibration planning per test volume: Systematic and random error values are listed by test volume (10, 5, 1 µL), requiring users to verify calibration for each specific volume used in their workflow to maintain ISO 8655-2 compliance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).