Description
dPette Single-channel 20-200 µL PipetteProduct Type: Electronic pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The lower half of this pipette is autoclavable for sterilization; the upper assembly must not be autoclaved. User calibration must follow ISO 8655-2 using the specified test volumes and error tolerances.
- Autoclave Sterilization: Only the lower half of the pipette is autoclavable; do not autoclave the upper assembly.
- User Calibration: Calibration must be performed according to ISO 8655-2 using the specified test volumes and error tolerances.
- Tip Compatibility: Use only compatible pipette tips designed for the 20–200 µL range to ensure proper fit and accuracy.
What is the accuracy trade-off when using the dPette 20-200 µL pipette at the lower end of its volume range?
At the lower end (20 µL), the systematic error is ±0.80 µL (±4.00%), which is a significantly higher relative error compared to the full volume (200 µL: ±1.20 µL, ±0.60%). This trade-off means that for applications requiring high precision at low volumes, the pipette's performance may be less reliable, and users should consider the increased percent error when setting up protocols.
What calibration standard does the dPette 20-200 µL pipette follow, and does it require user calibration?
The pipette is calibrated according to ISO 8655-2, and the technical table includes a user calibration reference. Users should verify calibration requirements before use, as the reference indicates that user calibration may be needed for specific applications.
What are the sterilization capabilities of the dPette 20-200 µL pipette?
The pipette's lower half is autoclavable, but the entire unit is not designed for full autoclaving. This constraint is important for laboratories that require sterile handling of the entire pipette for contamination-sensitive workflows.
The dPette Single-channel 20-200 µL Pipette provides reliable liquid handling with traceable calibration data and fine volume increment, but its high systematic error at low volumes and partial autoclavability impose constraints on accuracy-sensitive applications and full sterilization workflows.
Positive
- Single-channel precision for PCR setup: The single-channel format with 1 µL increment enables accurate single-tube sample preparation, serial dilution, and PCR/qPCR setup, providing reliable liquid handling for research and quality-control workflows.
- Traceable calibration data: Systematic and random error values are provided for each test volume (200/100/20 µL) referencing ISO 8655-2, allowing users to verify performance and plan calibration cycles.
Trade-offs
- High systematic error at 20 µL: At the lowest test volume of 20 µL, systematic error is ±0.80 µL (±4.00%), which may limit accuracy for applications requiring tight tolerances at low microliter volumes.
- Partial autoclavability only: Only the lower half of the pipette is autoclavable; the upper assembly cannot be sterilized, requiring careful handling to prevent contamination of non-sterilizable components.