Description

Mi-Pette 8-channel 30-300 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

Mi-Pette 8-channel 30-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 30-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 30-300 µL working range, 0.2 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 30-300 µL with 0.2 µL increment.
  • Sterilization suitability: High-temperature sterilization supported where indicated by source family.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MIPETTE-8CHANNEL-30-300-µL
Product Family Mi-Pette
Channel count 8-channel
Volume range 30-300 µL
Increment 0.2 µL
Test volume(s) 300 / 150 / 30 µL
Systematic error At 300 µL: ±4.8 µL (±1.6%); at 150 µL: ±4.8 µL (±3.2%); at 30 µL: ±4.8 µL (±16%)
Random error At 300 µL: ±1.8 µL (±0.6%); at 150 µL: ±1.8 µL (±1.2%); at 30 µL: ±1.8 µL (±6.0%)
Sterilization suitability High-temperature sterilization supported where indicated by source family
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires high-temperature sterilization compatibility verification and routine calibration per ISO 8655-2 to maintain specified accuracy. Tip compatibility must be confirmed for secure sealing and accurate volume delivery across the 30-300 µL range.

  • Sterilization Compatibility: Confirm that the autoclave cycle parameters are within the pipette's material tolerance to avoid damage during high-temperature sterilization.
  • Calibration Interval: Routine calibration per ISO 8655-2 is required, with performance verified at test volumes of 300, 150, and 30 µL.
  • Tip Sealing: Use only tips designed for 8-channel 30-300 µL pipettes to ensure consistent seal and prevent leakage.
  • Volume Increment: Set the volume in 0.2 µL increments within the 30-300 µL range to avoid mechanical overextension.

Perform calibration verification, select compatible tips, and sterilize as needed to ensure accurate and repeatable liquid handling. Follow these steps for safe and effective operation.

Required Equipment: Pipette tips (8-channel, 30-300 µL compatible)

  1. Verify Calibration
    Verify the pipette's calibration status against ISO 8655-2 and confirm that systematic and random errors at 300, 150, and 30 µL are within specified limits.
  2. Select and Attach Tips
    Select and attach compatible 8-channel tips that form a secure seal without requiring excessive force.
  3. Set Volume
    Set the target volume by rotating the thumb wheel to the desired value within the 30-300 µL range.
  4. Sterilize if Required
    If required, sterilize the pipette by placing it in an autoclave using a validated high-temperature cycle, then allow it to cool completely before reuse.

How does the systematic error of the Mi-Pette 8-channel 30-300 µL pipette vary across its volume range, and what is the proportional accuracy at the lowest test volume?

The systematic error is ±4.8 µL absolute at each test volume, but the relative error increases from ±1.6% at 300 µL to ±3.2% at 150 µL and to ±16% at 30 µL. This constant absolute error means proportional accuracy degrades significantly at low volumes, making the pipette less suitable for high-precision work near the 30 µL lower limit.

Is the Mi-Pette 8-channel pipette user-calibratable per ISO 8655-2, and what calibration data are provided?

Yes, the calibration reference is ISO 8655-2, indicating user calibration is supported. The technical specifications list systematic and random error values at 300, 150, and 30 µL for calibration verification. Users should confirm calibration intervals and procedure with Atomfair, as these are not specified in the product description.

Can the Mi-Pette 8-channel 30-300 µL pipette be sterilized by autoclaving, and what conditions are indicated?

Yes, the pipette is described as fully autoclavable. The technical specifications note high-temperature sterilization is supported where indicated by the source family. Specific temperature and cycle parameters are not provided, so users should consult the manufacturer for sterilization guidelines.

The Mi-Pette 8-channel 30-300 µL pipette provides efficient parallel liquid handling for microplate, PCR, and ELISA workflows, with full autoclavability for sterility. However, systematic and random errors increase significantly at the low end of the range (30 µL: systematic ±16%, random ±6.0%), which limits precision for small-volume transfers.

Positive

  • 8-channel parallel processing: The 8-channel configuration enables simultaneous multi-tip liquid transfer, supporting high-throughput microplate loading, PCR plate preparation, and ELISA workflows.
  • Fully autoclavable for sterility: The pipette is fully autoclavable, allowing high-temperature sterilization without disassembly for aseptic laboratory protocols.

Trade-offs

  • Large systematic error at 30 µL: At the minimum test volume of 30 µL, the systematic error is ±4.8 µL (±16%), which is proportionally very high and may compromise accuracy in low-volume applications.
  • High random error at low volume: Random error at 30 µL is ±1.8 µL (±6.0%), indicating poor repeatability for small-volume transfers compared to higher test volumes.