Description
Atomfair Battery Tester Product Information
Product Model
Atomfair-BTS-724
Release Date
2024-03-09
Version
V2.0
Dimensions & Weight
- Dimensions: 3U3F, 480 × 730 × 130 mm
- Weight: 5 kg
Product Overview
This battery testing system is designed for measuring battery performance within 50mA–20A, 0–5V range, and is an ideal tool for R&D of next-generation energy storage materials and rechargeable batteries.
Key Features
- High-precision programmable control: Flexible setting of test steps and working parameters, each working mode can be customized.
- 8 independent programmable channels per module: Built-in power supply and complete control circuit, each channel works independently and can be set with different modes.
- Full process controllability: Support GOTO, restart and resume functions, allowing modification of test parameters at any time.
- Windows-based software: User-friendly interface, stable performance, supports real-time monitoring, data and graph display, with English and Chinese prompts and alerts.
- Power-off data protection: No data loss during power failure, with comprehensive safety protection.
Technical Specifications
Electrical Input
- Input Power: AC 220V ±10%, 50Hz
- Input Active Power: 1418W
Measurement Performance
- Resolution: AD 16bit; DA 12bit
- Input Impedance: ≥1MΩ
Voltage Specifications
- Constant Voltage Range: 25mV~5V
- Minimum Discharge Voltage: 2.5V
- Accuracy: ±0.1% FS
- Stability: ±0.1% FS
Current Specifications
- Single Channel Output Range: 100mA~20A
- Accuracy: ±0.1% FS
- Constant Voltage Cut-off Current: 0.04A
- Stability: ±0.1% FS
Power Specifications
- Single Channel Output Power: 100W
- Stability: ±0.2% FS
Time & Response
- Current Rise Time: ≤20ms
- Single Step Time: ≤365×24 hours
- Minimum Sampling Time: 1s
- Recording Frequency: 1Hz
Data Sampling
- Minimum Sampling Voltage: 10mV
- Minimum Sampling Current: 40mA
Charge & Discharge Modes
- Charge Modes: Constant Current (CC), Constant Voltage (CV), CC-CV
- Discharge Modes: Constant Current (CC), Constant Power (CP), Constant Resistance (CR)
- Cut-off Conditions: Voltage, Current, Relative Time, Capacity, -ΔV
Cycle Test
- Cycle Count: 1~65535 times
- Steps per Cycle: 63
- Supports 3-level nested loops
Protection Functions
- Programmable upper/lower voltage limits, upper/lower current limits, delay time
- Hardware Protection Grade: IP20
Channel Design
- Dual closed-loop control for constant current / constant voltage
- Independent channel control
- 4-wire connection for voltage and current sampling
Environmental Requirements
- Operating Temperature: 0°C~40°C
- Storage Temperature: -10°C~50°C
- Operating Humidity: ≤70% RH (no condensation)
- Storage Humidity: ≤80% RH (no condensation)