Swagelok Two-Electrode Cell 10–20mm High-Purity Mo ATOMFAIR®

Price range: $139.95 through $159.95

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

High-purity Mo Swagelok two-electrode testing cell with hermetic fittings, modular assembly, and 10–20mm size options for battery R&D. Order now.

SKU: AFMSGTUN179
Category:
Brands:

ATOMFAIR® SWAGELOK TWO-ELECTRODE TESTING CELL (HIGH-PURITY MOLYBDENUM)

RESEARCH GRADE MATERIAL

Product Overview

The ATOMFAIR® premium Swagelok two-electrode **testing cell** is precision-crafted from **high-purity molybdenum** to deliver elite chemical stability and advanced corrosion resistance across aggressive battery research and development paradigms. Serving as an exceptional piece of **electrochemical testing equipment**, this robust apparatus streamlines the characterization of novel materials, reactive electrolytes, and advanced battery configurations. Integrated with high-integrity, secure **Swagelok fittings**, it ensures dependable electrical connectivity and flawless hermetic validation during prolonged charge-discharge cycles, avoiding baseline errors and yielding highly accurate datasets for advanced energy storage breakthroughs.

Technical Specifications

PARAMETER DETAILS
Equipment Type Electrochemical Testing Cell / Equipment
Electrode Configuration Two-Electrode Architecture
Structural Metallurgy High-Purity Molybdenum (Mo)
Connection Interfaces Secure Hermetic Swagelok Fittings
Design Form Factor Compact, Modular Layout for Rapid Benchtop Assembly
Battery Technology Adaptability Universal compatibility with Lithium-Ion, Solid-State, and Advanced Systems
Alternative Options Explore our related catalog or custom dimensions. For urgent technical custom requests or bulk inquiries, please contact our support team.

Key Features & Advantages

  • High-Purity Molybdenum Body: Engineered exclusively with premium molybdenum metallurgy to offer excellent mechanical endurance and supreme chemical passivity against volatile or reactive battery cell compounds.
  • Hermetic Fitting Security: Crafted with leak-proof Swagelok connector integration to fully prevent structural ambient moisture ingress or trace internal gas escape during high-sensitivity analytical testing.
  • Optimized Modular Assembly: Features a streamlined, compact spatial footprint that allows cleanroom technicians to complete rapid, user-friendly setup workflows without hardware baseline misalignment.
  • Broad Academic Adaptability: Universally compatible across a wide spectrum of lithium-ion, sodium-ion, and experimental solid-state setups for unbiased, high-fidelity electrode material evaluations.

APPLICATION SCOPE: Ideally optimized for advanced university laboratories and corporate cleanrooms executing lithium-ion characterization, fundamental electrochemical cell studies, high-rate transient cycling tests, and performance screening of emerging anode and cathode material formulations.
PACKAGING: Individually packaged within protective, contamination-free foam enclosures to safeguard the structural integrity of the fittings and polished internal surfaces. Custom bulk shipping layouts are accessible for high-throughput institutional evaluation centers.
IMPORTANT NOTICE: Thoroughly clean and dry all metallic elements using electronics-grade solvents after each experiment to prevent surface passivation. Always store the disassembled apparatus in a cool, dark, and desiccated space when idle. Comply strictly with localized institutional protocols when treating or disposing of residual hazardous electrode matrices or solvent-soaked components.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This testing cell requires thorough cleaning with electronics-grade solvents after each use to prevent surface passivation of the molybdenum body. Storage must be in a cool, dark, desiccated environment when disassembled to maintain structural integrity.

  • Surface Passivation Risk: Residual electrolyte can cause molybdenum surface passivation if not cleaned promptly after each experiment.
  • Hermetic Seal Requirement: Swagelok fittings must be properly tightened to maintain hermetic integrity and prevent ambient moisture ingress.
  • Hazardous Material Handling: Comply with institutional protocols when treating or disposing of residual hazardous electrode matrices or solvent-soaked components.
  • Storage Condition: Store the disassembled apparatus in a cool, dark, desiccated space when not in use to prevent corrosion.
  • Cleaning Procedure Necessity: Clean all metallic elements with electronics-grade solvents after each experiment to remove reactive residues.

After each experiment, disassemble the cell and clean all metallic components with electronics-grade solvents to prevent passivation. Dry thoroughly and store the disassembled apparatus in a cool, dark, desiccated space to preserve performance.

  1. Disassemble cell after experiment
    Disassemble the testing cell immediately after completing the electrochemical experiment to prevent residue buildup.
  2. Clean metallic components
    Clean all metallic elements using electronics-grade solvents to thoroughly remove residual electrolyte and contaminants.
  3. Dry components completely
    Dry the cleaned components completely using a lint-free cloth or air drying to eliminate moisture.
  4. Store in desiccated environment
    Store the disassembled apparatus in a cool, dark, desiccated space to maintain surface integrity and readiness for future use.

How does the high-purity molybdenum body of this Swagelok cell compare in corrosion resistance to standard stainless steel test cells for aggressive electrolytes?

The high-purity molybdenum body offers superior chemical passivity and corrosion resistance against volatile or reactive battery cell compounds compared to common stainless steel alternatives. This ensures stable baseline performance during prolonged charge-discharge cycles with aggressive electrolytes, though specific corrosion rate data is not provided in the source.

Which battery chemistries and electrode configurations are compatible with this two-electrode Swagelok test cell?

This cell is universally compatible with lithium-ion, sodium-ion, and experimental solid-state battery systems. Its two-electrode architecture and Swagelok fittings support high-fidelity electrode material evaluations without baseline errors, but three-electrode measurements are not supported as only two-electrode configuration is specified.

What are the recommended cleaning and storage procedures to maintain the integrity of the molybdenum surfaces after cycling with reactive electrolytes?

After each experiment, thoroughly clean and dry all metallic elements using electronics-grade solvents to prevent surface passivation. Store the disassembled apparatus in a cool, dark, and desiccated space when idle, and comply with local institutional protocols for disposal of residual hazardous electrode matrices or solvent-soaked components.

The Atomfair Swagelok two-electrode testing cell, constructed from high-purity molybdenum, offers excellent chemical stability and hermetic sealing for reliable electrochemical testing. However, it requires meticulous cleaning and dry storage to prevent surface passivation and maintain performance.

Positive

  • High-Purity Molybdenum Body: Engineered from premium molybdenum, providing excellent mechanical endurance and chemical passivity against volatile battery compounds.
  • Hermetic Swagelok Fittings: Leak-proof connectors prevent ambient moisture ingress and gas escape, ensuring accurate data during long cycling tests.

Trade-offs

  • Post-Experiment Cleaning Required: All metallic elements must be thoroughly cleaned and dried with electronics-grade solvents after each experiment to prevent surface passivation.
  • Specific Storage Conditions: Disassembled apparatus must be stored in a cool, dark, and desiccated space to maintain structural integrity and fitting performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

sizes

10mm, 12mm, 14mm, 16mm, 20mm