Swagelok Two-Electrode Testing Cell 10–20mm ATOMFAIR®

Price range: $129.95 through $149.95

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

TC4/304 stainless Swagelok two-electrode testing cell with 10–20mm sizes and hermetic fittings for Li-ion and solid-state battery R&D. Order now.

SKU: AFMSSWOJ112
Category:
Brands:

ATOMFAIR® SWAGELOK TWO-ELECTRODE TESTING CELL (TC4/304 STAINLESS STEEL)

RESEARCH GRADE MATERIAL

Product Overview

The ATOMFAIR® premium Swagelok two-electrode **testing cell** is precision-crafted from elite **TC4/304 stainless steel** to provide unmatched durability and baseline reliability across demanding battery research and development paradigms. As a critical piece of **electrochemical testing equipment**, this robust apparatus streamlines the evaluation of novel materials, electrolyte setups, and advanced cell configurations. Integrated with high-integrity, secure **Swagelok fittings**, it guarantees tight hermetic validation and dependable electrical contact during prolonged cycling matrices, eliminating gas leakage anomalies and ensuring high-fidelity data acquisition for lithium-ion and next-generation energy storage studies.

Technical Specifications

PARAMETER DETAILS
Equipment Type Electrochemical Testing Cell / Equipment
Electrode Configuration Two-Electrode Architecture
Structural Metallurgy High-Quality TC4 Titanium Alloy / 304 Stainless Steel
Connection Interfaces Secure Hermetic Swagelok Fittings
Design Form Factor Compact, Modular Layout for Rapid Benchtop Assembly
Battery Technology Adaptability Universal compatibility with Lithium-Ion, Solid-State, and Advanced Systems
Alternative Options Explore our related catalog or custom dimensions. For urgent technical custom requests or bulk inquiries, please contact our support team.

Key Features & Advantages

  • Premium Metallurgy Options: Constructed from ultra-durable TC4 and 304 stainless steel variants to provide exceptional mechanical rigidity and corrosion resistance against harsh organic electrolytes.
  • Hermetic Fitting Security: Engineered with leak-proof Swagelok connector integration to prevent structural ambient ingress or internal gas escape during high-pressure electrochemical analysis.
  • Optimized Modular Assembly: Features a streamlined, compact internal footprint that allows cleanroom technicians to carry out rapid, user-friendly setup operations without baseline component misalignment.
  • Broad Academic Adaptability: Universally compatible across a wide spectrum of lithium-ion, sodium-ion, and advanced energy storage configurations for unbiased electrode evaluation.

APPLICATION SCOPE: Ideally optimized for advanced university laboratories and corporate cleanrooms executing lithium-ion characterization, fundamental electrochemical cell studies, high-rate transient cycling tests, and performance screening of emerging anode and cathode material formulations.
PACKAGING: Individually packaged within protective, contamination-free foam enclosures to safeguard the structural integrity of the fittings and polished internal surfaces. Custom bulk shipping layouts are accessible for high-throughput institutional evaluation centers.
IMPORTANT NOTICE: Thoroughly clean and dry all metallic elements using electronics-grade solvents after each experiment to prevent surface passivation. Always store the disassembled apparatus in a cool, dark, and desiccated space when idle. Comply strictly with localized institutional protocols when treating or disposing of residual hazardous electrode matrices or solvent-soaked components.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This testing cell requires thorough cleaning with electronics-grade solvents after each experiment to prevent surface passivation. Storage must be in a cool, dark, and desiccated environment when the cell is disassembled and idle.

  • Cleaning Requirement: After each experiment, clean all metallic elements using electronics-grade solvents to remove electrolyte residues.
  • Drying Requirement: Ensure all components are thoroughly dried before reassembly or storage to prevent corrosion or contamination.
  • Storage Environment: Store the disassembled apparatus in a cool, dark, and desiccated space to maintain structural integrity and performance.
  • Hazardous Waste Compliance: Comply strictly with local institutional protocols when treating or disposing of residual hazardous electrode matrices or solvent-soaked components.

Proper maintenance ensures prolonged cell life and reliable electrochemical data. Follow these steps after each experiment to preserve the integrity of the stainless steel and titanium alloy components.

Required Equipment: Electronics-grade cleaning solvents

  1. Clean components
    Clean all metallic elements using electronics-grade solvents to remove electrolyte residues and prevent surface passivation.
  2. Dry components
    Dry each component thoroughly using a clean, dry environment or lint-free cloth to eliminate all moisture.
  3. Store disassembled
    Store the disassembled apparatus in a cool, dark, and desiccated space when not in use to avoid environmental degradation.
  4. Dispose of hazardous waste
    Comply with institutional protocols for the disposal of residual hazardous electrode matrices and solvent-soaked components.

How does the Swagelok fitting design in the Atomfair two-electrode testing cell prevent gas leakage during high-pressure electrochemical analysis?

The Swagelok fitting design provides leak-proof hermetic validation, preventing ambient air ingress and internal gas escape during high-pressure electrochemical analysis. This ensures reliable electrical contact and eliminates gas leakage anomalies that could compromise data integrity in long-term cycling experiments.

What electrode diameter sizes are available for the Atomfair Swagelok two-electrode testing cell to accommodate different electrode materials?

The Atomfair Swagelok testing cell is available in sizes of 10mm, 12mm, 14mm, 16mm, and 20mm, corresponding to the electrode diameter. Researchers should select the cell size that matches their electrode dimensions to ensure proper fit and electrical contact.

What are the proper cleaning and storage procedures for the Atomfair Swagelok cell to maintain performance and prevent contamination?

After each experiment, all metallic components must be thoroughly cleaned and dried using electronics-grade solvents to prevent surface passivation. When not in use, the apparatus should be stored disassembled in a cool, dark, and desiccated environment. Additionally, comply with institutional protocols for disposal of hazardous electrode materials and solvent-soaked components.

The Atomfair Swagelok two-electrode testing cell, precision-machined from TC4 titanium alloy and 304 stainless steel, offers hermetic sealing and corrosion resistance for high-fidelity cycling of lithium-ion, sodium-ion, and solid-state battery chemistries. Available in diameters from 10mm to 20mm, its compact modular design facilitates rapid benchtop assembly, though diligent cleaning with electronics-grade solvents and desiccated storage are required to prevent surface passivation.

Positive

  • Premium corrosion-resistant metallurgy: Constructed from TC4 titanium alloy and 304 stainless steel, the cell exhibits exceptional mechanical rigidity and resistance to harsh organic electrolytes, ensuring long-term structural integrity during electrochemical testing.
  • Hermetic Swagelok fitting security: Leak-proof Swagelok connectors prevent ambient ingress and internal gas escape during high-pressure cycling, enabling high-fidelity data acquisition without contamination artifacts.

Trade-offs

  • Requires rigorous post-experiment cleaning: All metallic elements must be thoroughly cleaned and dried with electronics-grade solvents after each use to prevent surface passivation, and the disassembled cell must be stored in a cool, dark, desiccated environment when idle.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

sizes

10mm, 12mm, 14mm, 16mm, 20mm