Ultraviolet Oil Analyzer Water 225nm ±0.1nm ATOMFAIR®

$8,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

UV-Oil 510 measures petroleum hydrocarbons in water at 225nm with ≤0.005mg/L detection limit, ±0.1nm wavelength accuracy, and RS232/USB connectivity.

SKU: AFMSMJXA604
Category:
Brands:

 

Atomfair UV-Oil 510 Ultraviolet Oil Analyzer

Product Overview

Atomfair UV-Oil 510 is a professional ultraviolet oil analyzer developed in accordance with international testing standards, specially designed for the determination of petroleum hydrocarbons in surface water, groundwater and seawater. Equipped with high-precision optical components and intelligent detection technology, it features high measurement accuracy, good repeatability and easy operation, providing accurate and efficient petroleum content detection solutions for water quality monitoring and environmental testing scenarios.

Core Advantages

1. Ultimate Detection Precision: Equipped with micrometer-level precision screw drive grating, matched with 1200 lines/nm high-performance grating and imported receiver, the wavelength accuracy reaches ±0.1nm, transmittance accuracy ±0.1%, ensuring accurate and reliable detection data.

2. Ultra-sensitive Low-limit Detection: The detection limit is ≤0.005mg/L, the detection limit of oil concentration in enriched water 3SD < 0.1mg/L, the absorbance linear range is 0.0000~1.9999AU, the linear relationship > 0.999, which can accurately capture trace petroleum substances.

3. Intelligent & Convenient Operation: Support two modes of single-point rapid calibration and standard curve calibration, automatically complete wavelength calibration and setting; freely set the volume of water sample and n-hexane, automatically calculate and display the concentration of solution and water sample; equipped with 128*64 dot matrix LCD display, support stand-alone operation or computer connection, the process is efficient and worry-free.

4. Excellent Optical Performance: Spectral bandwidth 1.8nm, stray light only 0.01%T, baseline flatness ±0.001nm, strong optical stability and outstanding anti-interference ability, ensuring detection accuracy in complex water quality environment.

5. Global Voltage Adaptation: Support AC 110/220V 50/60Hz wide voltage input, adapt to power standards in different regions of the world, with a wider scope of application.

Technical Parameters

Technical Index    Specification Parameters

Detection Wavelength    225nm

Reagent Used    n-Hexane

Wavelength Accuracy    ±0.1nm

Wavelength Repeatability    ≤0.1nm

Spectral Bandwidth    1.8nm

Stray Light    0.01%T

Detection Limit    ≤0.005mg/L

Measurement Repeatability    <2%

Measurement Accuracy    ±2%

Absorbance Linear Range    0.0000~1.9999AU

Linear Relationship    >0.999

Measurement Range (Enriched Oil Concentration in Water)    0.0~50mg/L

Detection Limit 3SD (Enriched Oil Concentration in Water)    <0.1mg/L

Baseline Flatness    ±0.001nm

Communication Interface    RS232, USB

Overall Dimension (mm)    545×468×245

Weight (Kg)    16

Power Supply    AC 110/220V 50/60Hz

Working Humidity    <80%

 

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.

 

How does the UV-Oil 510 maintain accuracy at detection limits as low as 0.005 mg/L while handling enriched oil concentrations up to 50 mg/L?

The UV-Oil 510 achieves a detection limit of ≤0.005 mg/L and an absorbance linear range of 0.0000–1.9999 AU with linearity >0.999, enabling quantification across a wide dynamic range. The micrometer-level precision screw drive grating and 1200 lines/nm high-performance grating ensure wavelength accuracy of ±0.1 nm and transmittance accuracy of ±0.1%, preserving measurement fidelity at both trace and higher concentrations.

What are the specific solvent and sample preparation requirements for the UV-Oil 510 ultraviolet oil analyzer?

The instrument exclusively uses n-hexane as the extraction reagent for petroleum hydrocarbon determination in surface water, groundwater, and seawater samples. It supports freely settable volumes of both water sample and n-hexane, and automatically calculates solution and water sample concentrations. Users must provide compatible n-hexane and ensure samples are free from particulates that could affect optical measurements.

What environmental and infrastructure conditions are required to operate the Atomfair UV-Oil 510 reliably?

The UV-Oil 510 requires a working humidity below 80% and accepts AC 110/220V 50/60Hz power without need for voltage conversion. The instrument weighs 16 kg and measures 545×468×245 mm, requiring a stable benchtop. Use of n-hexane as a flammable solvent mandates proper ventilation and fume handling in the laboratory.

The Atomfair UV-Oil 510 is a fixed-wavelength (225 nm) UV analyzer for petroleum hydrocarbons in water, delivering ±0.1 nm wavelength accuracy and a detection limit of ≤0.005 mg/L, with n-hexane as the required reagent and a 16 kg benchtop footprint.

Positive

  • High-precision optical chain: Micrometer-level screw drive grating with 1200 lines/nm and imported receiver delivers ±0.1 nm wavelength accuracy and ±0.1% transmittance accuracy, ensuring reliable quantification of trace petroleum hydrocarbons.
  • Ultra-low detection capability: Detection limit of ≤0.005 mg/L and enriched-water 3SD <0.1 mg/L enable measurement of trace oil concentrations, with linearity >0.999 across 0.0000–1.9999 AU for dependable calibration curves.

Trade-offs

  • Requires n-hexane reagent: Operation depends on n-hexane as the extraction solvent, introducing chemical handling, disposal, and supply-chain requirements in the laboratory workflow.
  • Fixed 225 nm wavelength: Detection is locked at 225 nm, limiting applicability to petroleum hydrocarbons that absorb at this wavelength and preventing spectral scanning for other analytes without additional instrumentation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).