Top-Light Incubator, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator must be operated on a level surface with adequate ventilation and within an ambient temperature range of 5 to 40°C and relative humidity below 90%. When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain stability.
- Leveling and Ventilation: The incubator must be placed on a level surface with sufficient clearance around the cabinet for adequate ventilation.
- Ambient Temperature Limits: The ambient temperature must be maintained between 5°C and 40°C with relative humidity below 90%; when the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
- Transport and Positioning: The unit must be kept upright during unloading and positioning to prevent damage to the refrigeration system.
- Electrical and Safety Systems: The incubator requires a 220V 50Hz power supply and includes over-temperature self-limiting and power-off memory protection.
- Shelf and Lighting Configuration: Confirm the shelf arrangement and lighting level before operation to ensure proper airflow and illumination for the samples.
This procedure describes the initial setup and safe operation of the incubator for illuminated incubation tasks. Follow these steps to position, configure, and start the chamber for routine use.
Required Equipment: Top-Light Incubator, 150 L
- Position the incubator
Position the incubator on a level, stable surface with adequate clearance for ventilation. - Connect to power
Connect the power cord to a properly grounded AC220V 50Hz outlet rated for 600 W. - Set temperature and light
Set the desired temperature and light intensity using the LCD controller, ensuring the ambient temperature does not exceed 26°C if the set temperature is below 10°C. - Load samples
Arrange the shelves and load samples, ensuring even weight distribution and unobstructed airflow. - Start the program
Close the glass door and start the program; verify that the chamber reaches the set conditions within the specified uniformity.
What is the maximum ambient temperature allowed when the Top-Light Incubator 150 L is set to 10°C or below?
When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. The general work environment is 5 to 40°C with relative humidity below 90%, but this low-temperature setpoint requires a stricter ambient limit to maintain performance and prevent condensation or thermal overload.
Can the Top-Light Incubator 150 L be used for non-illuminated microbial culture?
Yes, the incubator supports microbial culture and preservation as stated in its application scope. The light intensity can be set to 0 lux (off), and the programmable controller allows dark incubation cycles. The temperature control range of 5 to 60°C and ±1°C uniformity are suitable for routine microbial work without illumination.
What safety mechanisms protect the Top-Light Incubator and its samples during a power interruption?
The incubator includes power-off memory that automatically preserves temperature and light program settings after a power interruption, eliminating the need for reprogramming. Additional safety features include self-diagnosis and over-temperature self-limiting protection to safeguard samples and the chamber during routine use.
The Atomfair Top-Light Incubator, 150 L (AF-LE-E-GZXT-0150-150T) is a programmable illuminated chamber offering 150 L capacity, 5–60 °C temperature control with ±1 °C uniformity, and 0–10,000 lux top lighting in 6 steps. Its mirror-finish stainless-steel interior, glass inner door, and LCD controller support routine plant growth, tissue culture, and microbial preservation applications, though ambient temperature must be kept at or below 26 °C when set temperature is 10 °C or lower.
Positive
- Programmable temperature and light control: The LCD microcomputer controller supports programmable temperature and light settings with a timer range of 0–9999 min, enabling repeatable photoperiod experiments and illuminated incubation workflows without manual intervention.
- Corrosion-resistant stainless-steel chamber: The mirror-finish stainless-steel inner chamber and tempered-glass inner door facilitate routine cleaning and visual inspection while providing corrosion resistance for long-term laboratory use.
Trade-offs
- Ambient temperature constraint at low setpoints: When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C, which may require additional climate control in warm laboratory environments.
- Top-light configuration limits illumination uniformity: The top-light layout with 2 faces and 6 intensity levels provides up to 10,000 lux, but side-lighting or multi-angle illumination is not available, restricting uniform light distribution for certain tall or dense sample arrangements.