Three-Sided Climate Chamber 1500 L 18000 lx ATOMFAIR®

$18,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1500 L three-sided strong-light climate chamber with 5-60 °C no-light control, 10-60 °C illuminated control, 0-18000 lx lighting and built-in humidification.

SKU: AF-LE-E-GZXS-1500-1500
Category:
Brands:

Three-Sided Strong-Light Climate Chamber, 1500 L
Research-grade laboratory product
Product Overview

Three-Sided Strong-Light Climate Chamber, 1500 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 1500 l of usable space, No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C and 0 to 18000 lx illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet uses a stainless-steel working chamber, a strong-light layout and a visible observation door to support stronger cultivation conditions. The cabinet uses a stainless-steel working chamber, a cold-rolled steel exterior and a three-sided strong-light layout, with an internal working room of 850 x 1500 x 1200 mm and an external footprint of 1050 x 1700 x 1860 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The strong-light series is designed for high-light cultivation and climate work that also needs built-in humidification support. The stated input power is 2000 W, and the timer range is 0 to 9999 minutes. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-GZX1500S
Capacity 1500 L
Temperature Control Range No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 2 C
Humidification Built-in humidification for high-temperature and high-humidity operation
Light Intensity 0 to 18000 LX
Lighting Faces 3 faces
Controller LCD microcomputer programmable controller
Chamber Material Stainless-steel working chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 2000 W
Power Supply AC220 50Hz
Timer Range 0 to 9999 minutes
Internal Dimensions 850 x 1500 x 1200 mm
External Dimensions 1050 x 1700 x 1860 mm
Net Weight 480 Kg
Shelves / Trays 2 shelves
Configuration Note When set temperature is 10 C or below, ambient temperature should not exceed 26 C; performance data are measured under no-load conditions at ambient temperature 20 C and ambient humidity 50%RH
Performance Features
  • Three-sided strong lighting helps deliver the higher illumination needed for strong-light cultivation. This supports repeatable plant-growth and photoperiod experiments.
  • Built-in humidification supports high-temperature and high-humidity operation. This is useful for cultivation, conditioning and biological workflows that need moisture control.
  • Programmable control of temperature and light supports repeatable experimental conditions. This supports repeatable plant-growth and photoperiod experiments.
  • Temperature alarms and protective functions help safeguard samples during longer runs. This helps protect samples and alerts operators when abnormal conditions occur.
  • Stainless-steel chamber construction supports cleaning and routine maintenance. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • The larger capacity options suit heavier sample loading and broader experimental layouts. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber level, confirm the room environment and leave enough ventilation space around the cabinet before operation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When set temperature is 10 C or below, ambient temperature should not exceed 26 C. Performance data are measured under no-load conditions at ambient temperature 20 C and ambient humidity 50%RH. The work environment should stay within 5 to 40 C and below 90%RH. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires specific environmental conditions for safe and accurate operation. Failure to observe these constraints may affect performance or damage samples.

  • Low-Temperature Ambient Limit: When set temperature is 10C or below, ambient temperature must not exceed 26C.
  • Operating Environment Range: The work environment must remain within 5C to 40C and below 90% relative humidity.
  • Installation Surface and Ventilation: Place the chamber on a level surface and ensure adequate ventilation space around the cabinet.
  • Power Supply Requirement: The chamber requires a 2000W, AC220V 50Hz power supply connection.

Follow these steps to prepare the chamber for operation. Proper setup ensures reliable performance and sample safety.

  1. Keep Upright
    Keep the chamber upright during unloading and positioning to prevent damage.
  2. Level the Chamber
    Place the chamber on a level surface to ensure stability and proper operation.
  3. Verify Ambient Conditions
    Confirm that the ambient temperature and humidity are within the specified operating limits of 5C to 40C and below 90%RH.
  4. Ensure Ventilation
    Leave enough ventilation space around the cabinet to allow adequate airflow.

Why is the temperature control range narrower in illuminated mode (10–60 °C) than in no-light mode (5–60 °C)?

The illuminated mode generates additional heat from the three-sided strong-light system, which raises the minimum achievable temperature. The product specification explicitly states a no-light range of 5 to 60 °C and an illuminated range of 10 to 60 °C, reflecting this thermal load. Researchers planning low-temperature light experiments must account for this 5 °C offset.

What ambient temperature constraint applies when operating the chamber at a set temperature of 10 °C or below?

When the set temperature is 10 °C or lower, the ambient room temperature must not exceed 26 °C. This condition is stated in the product's configuration note and performance data section. It is critical for maintaining stable low-temperature operation and preventing chamber overwork or drift.

What power supply and installation requirements must be met for the 1500 L climate chamber?

The chamber requires a 220 V, 50 Hz AC power supply with a 2000 W input. Installation requires a level floor, adequate ventilation space around the cabinet, and an ambient environment of 5–40 °C with relative humidity below 90 %RH. The unit weighs 480 kg and must be kept upright during transport and positioning.

The Atomfair Three-Sided Strong-Light Climate Chamber (1500 L) delivers 18000 lx from three sides and includes built-in humidification for high-temperature/high-humidity operation, but its ±2°C temperature uniformity and ambient temperature restrictions (≤26°C at low setpoints) require careful lab placement for reliable performance.

Positive

  • Three-sided strong-light illumination: Three-sided lighting provides up to 18000 lx, supporting high-light cultivation and photoperiod experiments with repeatable conditions.
  • Built-in humidification for high humidity: Integrated humidification enables high-temperature and high-humidity operation, useful for biological workflows and conditioning tasks requiring moisture control.

Trade-offs

  • Temperature uniformity ±2°C: The specified ±2°C temperature uniformity may limit precision for experiments requiring tight thermal gradients across the 1500 L chamber.
  • Ambient temperature constraints at low setpoints: When set temperature is 10°C or below, ambient temperature must not exceed 26°C; performance data are under no-load conditions, so real-world thermal loads may affect stability.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).