Temperature and Humidity Chamber 50 L AF-HSP50BE ATOMFAIR®

$1,200.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 50 L temperature and humidity chamber with 5–50 °C control, 50–90%RH range, 304 stainless-steel chamber and 500 W input. Order now.

SKU: AF-LE-E-HSPB-0050-50BE
Category:
Brands:

Temperature and Humidity Chamber, 50 L
Research-grade laboratory product
Product Overview

Temperature and Humidity Chamber, 50 L is a practical chamber for environmental protection, epidemic prevention, veterinary research, drug testing, aquatic research, BOD measurement, microbial culture, plant cultivation and breeding tests. It brings together 50 l of usable space, 5 to 50 C, 50%rh to 90%rh humidity control, so the chamber can keep samples in a steady, repeatable working condition.

The inner door uses tempered glass, the outer door uses a magnetic sealing strip, and the ducted air system helps improve chamber uniformity and observation convenience. The cabinet uses a stainless-steel chamber with rounded corners, removable shelves, a magnetic door seal and hot-cold air ducts, with an internal working room of 320 x 400 x 400 mm and an external footprint of 560 x 560 x 1070 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series combines temperature and humidity control with memory and self-diagnosis functions so that the chamber can keep operating reliably after power interruptions or alarms. The stated input power is 500 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-HSP50BE
Capacity 50 L
Temperature Control Range 5 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation +/- 1 C
Humidity Range 50%RH to 90%RH
Humidity Deviation < 8%RH
Controller LCD screen with programmable temperature, humidity and time control
Chamber Material 304 stainless-steel working chamber
Exterior Shell Powder-coated steel shell
Power / Input 500 W
Power Supply AC 220 V, 50 Hz
Timer Range 0 to 9999 min
Internal Dimensions 320 x 400 x 400 mm
External Dimensions 560 x 560 x 1070 mm
Net Weight 57.5 Kg
Shelves / Trays 2 shelves
Configuration Note Note: when set temperature is 10 C or below, ambient temperature should not exceed 26 C; when the set temperature is above 40 C, humidity setpoints should generally not exceed 80%
Performance Features
  • Self-diagnosis and over-temperature self-limiting help protect samples and reduce running risk. This supports more reliable day-to-day chamber use.
  • Power-off memory preserves settings after interruptions and supports continuous workflows. This helps preserve operation settings after power interruptions.
  • The embedded screen and multi-parameter display make operation and status review straightforward. This supports more reliable day-to-day chamber use.
  • The magnetic outer door seal and tempered-glass inner door improve sealing and observation. This improves observation and helps reduce heat loss while checking samples.
  • Hot and cold air ducts help improve chamber circulation and temperature uniformity. This helps improve chamber circulation and temperature uniformity.
  • Programmable temperature, humidity and time control suits repeatable laboratory methods. This is useful for cultivation, conditioning and biological workflows that need moisture control.
APPLICATION SCOPE: Suitable for environmental protection, epidemic prevention, veterinary research, drug testing, aquatic research, BOD measurement, microbial culture, plant cultivation and breeding tests in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber upright, maintain clear air paths and allow sufficient service space around the unit for ventilation and maintenance. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. When the set temperature is above 40 C, the humidity setpoint is normally kept below 80% to protect service life. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

When set temperature is 10 °C or below, ambient temperature must not exceed 26 °C. When set temperature exceeds 40 °C, humidity setpoints should not exceed 80% to protect service life.

  • Ambient temperature limitation: Operation at low set temperatures requires the ambient temperature to remain at or below 26 °C.
  • Humidity setpoint limitation under high temperature: At set temperatures above 40 °C, the humidity setpoint must be kept below 80% to prevent reduced service life.

Position the chamber upright with clear air paths and sufficient service space. Program temperature, humidity, and time settings via the LCD controller before loading samples.

Required Equipment: LCD controller with programmable interface, Tempered-glass inner door, Removable shelves

  1. Position the chamber
    Place the chamber on a level surface with at least 10 cm clearance around all sides for ventilation and maintenance access.
  2. Connect power supply
    Plug the chamber into a grounded AC 220 V, 50 Hz outlet rated for at least 500 W continuous load.
  3. Set target parameters
    Use the LCD controller to program the desired temperature, humidity percentage, and timer duration for the experiment.
  4. Verify environmental conditions
    Confirm that ambient temperature does not exceed 26 °C if the set temperature is 10 °C or below.
  5. Load samples
    Place sample containers on the removable shelves, ensuring at least 2 cm spacing between items for uniform airflow.
  6. Close doors and start cycle
    Close the inner tempered-glass door followed by the outer magnetic-seal door, then press start on the LCD controller.
  7. Monitor self-diagnosis indicators
    Observe the LCD display for self-diagnosis or over-temperature alerts and do not override the automatic shutoff.

What are the operating temperature and humidity constraints for the Atomfair AF-HSP50BE 50 L chamber?

The AF-HSP50BE has a temperature control range of 5 to 50 °C with ±1 °C fluctuation and a humidity range of 50% to 90% RH with <8% RH deviation. However, when the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C, and when the set temperature exceeds 40 °C, humidity setpoints should generally not exceed 80% to protect service life.

How does the Atomfair AF-HSP50BE maintain temperature uniformity and observation convenience?

The chamber uses a ducted hot and cold air system to improve circulation and temperature uniformity. For observation and sealing, it features a tempered-glass inner door and an outer door with a magnetic sealing strip, which minimizes heat loss while allowing visual sample inspection without disturbing the internal environment.

What power and infrastructure requirements are needed for the AF-HSP50BE temperature and humidity chamber?

The chamber has a rated input power of 500 W and requires an AC 220 V, 50 Hz power supply. Its external footprint is 560 x 560 x 1070 mm, and the unit must be kept upright with clear air paths and sufficient service space for ventilation and maintenance. Ambient temperature constraints apply when operating below 10 °C.

The Atomfair AF-HSP50BE (50L) offers a stainless-steel chamber with 5–50°C and 50–90%RH control, LCD programming, and self-diagnostic protection for biological and environmental testing, but requires careful attention to ambient temperature and humidity setpoint limits for stable operation.

Positive

  • 304 stainless-steel chamber with rounded corners: The working chamber is 304 stainless steel with rounded corners, simplifying cleaning and reducing contamination risk in biological and microbial culture applications.
  • Power-off memory and self-diagnosis: The controller retains programmed settings after power interruptions and performs self-diagnosis with over-temperature limiting, supporting unattended continuous operation.

Trade-offs

  • Ambient temperature constraint at low setpoints: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C, which may require air-conditioned lab space for low-temperature tests.
  • Humidity limitation above 40°C: At set temperatures above 40°C, humidity setpoints should generally not exceed 80%RH to protect component service life, restricting high-humidity high-temperature testing.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).