Double-Zone Sliding 2D Growth System 1200 °C 50 mm

$6,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Double-zone sliding 2D materials preparation system with 1200 °C maximum temperature, 1100 °C working temperature, 5 kW power and 50 mm quartz tube. Order now.

SKU: AF-TD-T-1200-2DSL-002J
Category:
Brands:

Double-Zone Sliding Two-Dimensional Materials Preparation System, 50 mm Tube, 1200 °C
TWO-DIMENSIONAL MATERIAL GROWTH EQUIPMENT
Product Overview

Double-Zone Sliding Two-Dimensional Materials Preparation System, 50 mm Tube, 1200 °C is configured for two-dimensional material growth and low-vacuum CVD-style laboratory preparation workflows.

This product is distinguished by double zone sliding two-dimensional preparation equipment and its process-specific configuration.

Confirm the tube size, heating-zone layout, gas-flow range, vacuum pump package, temperature-control configuration and accessories before quotation.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model TD-1200-2J
Product Family Double Zone Sliding Two-Dimensional Preparation Equipment
Rated Power 5 kW.
Maximum Temperature 1200 °C.
Working Temperature 1100 °C.
Maximum Heating/Cooling Rate 10 °C/min.
Tube Size High-purity quartz tube, 50 mm x 1400 mm; customized tube options should be confirmed.
Heating Zone Length 200 mm + 200 mm.
Constant Zone Length 200 mm.
Configuration Highlights
  • Split vacuum tube-furnace layout supports quick heating and cooling by moving the constant zone toward or away from the sample area.
  • The system is positioned for low-vacuum CVD and two-dimensional material preparation.
  • Atmosphere micro-adjustment and gas-pressure configuration should be confirmed for the target process.
APPLICATION SCOPE: Thin-film deposition, two-dimensional material growth, semiconductor-material preparation and atmosphere-controlled laboratory process development.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging for handling, storage and delivery.
IMPORTANT NOTICE: Please confirm tube size, heating-zone arrangement, gas-flow channels, vacuum pump package, power supply and required accessories before quotation.
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The system is rated for a maximum operating temperature of 1200 °C and a working temperature of 1100 °C with a heating/cooling rate limit of 10 °C/min. The high-purity quartz tube requires careful thermal management to prevent thermal shock and maintain vacuum integrity.

  • Temperature and Rate Limits: The maximum operating temperature is 1200 °C with a working temperature of 1100 °C, and the heating/cooling rate must not exceed 10 °C/min.
  • Tube and Vacuum Handling: The high-purity quartz tube (50 mm x 1400 mm) requires gentle handling to avoid thermal shock and must be used under low-vacuum conditions as specified.

What is the practical difference between the 1200 °C maximum temperature and the 1100 °C working temperature on the Atomfair TD-1200-2J?

The TD-1200-2J has a stated maximum temperature of 1200 °C and a working temperature of 1100 °C. The system also has a maximum heating/cooling rate of 10 °C/min, so thermal ramp planning should respect that rate limit rather than assuming faster cycling to the maximum temperature.

Can this double-zone sliding furnace be used for low-vacuum CVD growth of two-dimensional materials?

Yes. The system is explicitly positioned for low-vacuum CVD-style laboratory preparation and two-dimensional material growth, with a split vacuum tube-furnace layout that supports rapid heating and cooling by moving the constant zone toward or away from the sample area. It uses a high-purity quartz tube (50 mm x 1400 mm) with two 200 mm heating zones and a 200 mm constant zone; however, atmosphere micro-adjustment and gas-pressure configuration should be confirmed for the target process.

What configuration details must be confirmed before installing or quoting this system?

Before quotation, the tube size, heating-zone arrangement, gas-flow channels, vacuum pump package, power supply, and required accessories must be confirmed for the target process. The system is rated at 5 kW and uses a high-purity quartz tube; atmosphere micro-adjustment and gas-pressure configuration also need to be verified.

The Double-Zone Sliding Two-Dimensional Materials Preparation System (50 mm tube, 1200 °C) offers a split vacuum tube-furnace design enabling rapid thermal cycling by zone translation, tailored for low-vacuum CVD and 2D material growth, but requires process-specific configuration of gas, vacuum, and tube parameters.

Positive

  • Split furnace for rapid thermal cycling: The sliding zone design allows the constant-temperature zone to be moved toward or away from the sample, enabling faster heating and cooling without waiting for the entire tube to change temperature, improving process throughput.
  • Optimized for low-vacuum CVD and 2D materials: The system is purpose-configured for thin-film deposition, two-dimensional material growth, and semiconductor material preparation under controlled atmosphere, matching the infrastructure requirements of these workflows.

Trade-offs

  • Process-dependent configuration required: Parameters such as tube size, heating-zone layout, gas-flow range, vacuum pump package, and power supply must be confirmed per target process, meaning the system is not ready-to-run without pre-sales engineering review.
  • Limited heating and cooling rate: The maximum ramp rate of 10 °C/min may constrain processes requiring rapid thermal transients, especially for temperature-sensitive substrate or precursor steps.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).