Semiconductor Cooling Low-Temperature Incubator 100 L ATOMFAIR®

$4,400.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 100 L semiconductor cooling low-temperature incubator with 5-65 °C control, ±0.2 °C accuracy, and 480 × 400 × 560 mm chamber. In stock.

SKU: AF-LE-E-SCLT-0100-C100
Category:
Brands:

100 L Semiconductor Cooling Low-Temperature Incubator with Peltier Cooling
Research-grade laboratory product
Product Overview

100 L Semiconductor Cooling Low-Temperature Incubator with Peltier Cooling is designed for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows. Peltier semiconductor cooling, touchscreen control, rapid recovery, and adjustable circulation fan settings for low-temperature laboratory use. The configuration provides 5 to 65 °C, Cooling 360 W / heating 500 W rated power, a working chamber of 480 × 400 × 560 mm (W × D × H), and external dimensions of 668 × 675 × 752 mm (W × D × H).

The control and chamber design support practical laboratory operation: 7-inch intelligent touchscreen controller. 304 stainless-steel inner chamber with adjustable shelves and glass inner door

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include UV sterilization system; printer or RS485 communication interface; USB data export; electronic signature function; smart App control system.

This equipment is suited to laboratories that need low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-SCLI-100
Product Family Semiconductor Cooling Low-Temperature Incubator
Configuration 100 L
Rated Operating Power Cooling 360 W / heating 500 W
Working Chamber Size 480 × 400 × 560 mm (W × D × H)
Overall Dimensions 668 × 675 × 752 mm (W × D × H)
Controller 7-inch intelligent touchscreen controller
Temperature Control Range 5 to 65 °C
Temperature Accuracy ±0.2 °C
Temperature Uniformity ±0.5 °C at 37 °C and ±0.5 °C at 25 °C
Temperature Sensor Dual Pt100 sensors
Door Recovery Time No more than 5 minutes after a 30-second door opening at 37 °C
Standard Shelves 2 shelves
Power Supply AC 220 V or 110 V, 50 Hz
Chamber Design 304 stainless-steel inner chamber with adjustable shelves and glass inner door
Optional Accessories and Functions UV sterilization system; printer or RS485 communication interface; USB data export; electronic signature function; smart App control system
Performance Features
  • Peltier semiconductor cooling provides both cooling and heating without compressor-based refrigeration in this product family. This supports efficient low-temperature operation for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • A rapid recovery design restores the working temperature after a 30-second door opening within the stated limit of 5 minutes at 37 °C. This supports controlled, repeatable operation for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • An adjustable circulation fan supports a balance between chamber uniformity and sample protection from excessive airflow. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Foamed cabinet insulation reduces heat loss and supports stable low-temperature control. This supports controlled, repeatable operation for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • A password lock, USB data export, bilingual interface, and optional electronic signature and App monitoring support recorded operation. This allows the configuration to match documentation, communication and monitoring needs in low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • High and low temperature alarms provide audible and visual notification during operation. This helps operators identify abnormal conditions during unattended or extended low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
APPLICATION SCOPE: Suitable for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 668 × 675 × 752 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: UV sterilization system; printer or RS485 communication interface; USB data export; electronic signature function; smart App control system. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a stable AC 220 V or 110 V, 50 Hz power supply and adequate clearance for the 668 × 675 × 752 mm external dimensions. Door recovery time must not exceed 5 minutes after a 30-second opening at 37 °C to maintain temperature uniformity.

  • Power Supply Requirement: Confirm the available power supply matches the specified AC 220 V or 110 V, 50 Hz before installation.
  • Spatial Clearance: Ensure the installation space accommodates the external dimensions of 668 × 675 × 752 mm for proper ventilation and access.
  • Temperature Recovery Constraint: Maintain door openings to under 30 seconds to ensure the chamber recovers to set temperature within 5 minutes at 37 °C.
  • Sensor Accuracy: Dual Pt100 sensors must be kept accessible for calibration to maintain temperature accuracy of ±0.2 °C.

Position the incubator on a level surface with adequate clearance and connect to the specified power supply. Configure the temperature setpoint and circulation fan settings via the 7-inch touchscreen controller before loading samples.

Required Equipment: 7-inch intelligent touchscreen controller, Adjustable shelves

  1. Position the Incubator
    Place the incubator on a level, stable surface with at least 10 cm clearance around all sides for airflow.
  2. Connect Power Supply
    Connect the incubator to a grounded AC 220 V or 110 V, 50 Hz power outlet using the provided cable.
  3. Set Temperature Parameters
    Use the touchscreen controller to set the desired temperature within the 5 to 65 °C range and confirm the setpoint.
  4. Adjust Circulation Fan
    Set the adjustable circulation fan speed to balance chamber uniformity and sample protection from airflow.
  5. Load Samples
    Place samples on the adjustable shelves, ensuring they do not block the internal air circulation or sensors.
  6. Verify Door Seal
    Close the glass inner door and outer door firmly, then confirm the door recovery time is within 5 minutes at 37 °C.
  7. Enable Alarms
    Activate high and low temperature alarms via the controller to receive audible and visual notifications during operation.

What are the temperature control and recovery performance characteristics of the Atomfair 100 L semiconductor cooling incubator?

The Atomfair AF-SCLI-100 incubator provides a temperature control range of 5 to 65 °C with an accuracy of ±0.2 °C and uniformity of ±0.5 °C at both 37 °C and 25 °C. Door recovery time is specified as no more than 5 minutes after a 30-second opening at 37 °C, enabled by the Peltier semiconductor cooling and rapid recovery design.

Which optional communication and monitoring interfaces are available for the AF-SCLI-100 incubator?

The incubator supports optional printer or RS485 communication interface, USB data export, electronic signature function, and a smart App control system. These optional accessories and functions are selected according to the required workflow, as noted in the product's technical specifications.

What are the power supply requirements and alarm features of the 100 L semiconductor cooling incubator?

The incubator requires AC 220 V or 110 V, 50 Hz power supply. It includes high and low temperature alarms that provide audible and visual notification during operation. The chamber is constructed from 304 stainless steel with adjustable shelves and a glass inner door, and a password lock is standard for security.

The 100 L Semiconductor Cooling Low-Temperature Incubator (AF-SCLI-100) utilizes Peltier thermoelectric cooling for compressor-free temperature control from 5 to 65°C with ±0.2°C accuracy and ≤5 min door recovery, designed for low-temperature microorganism cultivation, sample storage, and plant breeding applications.

Positive

  • Peltier Semiconductor Cooling System: Provides both cooling and heating without a compressor, enabling efficient low-temperature operation from 5 to 65°C with reduced mechanical complexity and vibration.
  • Rapid Door Recovery: Recovers to set temperature within 5 minutes after a 30-second door opening at 37°C, supporting workflow continuity and sample stability.

Trade-offs

  • Power Supply Requirements: Requires a dedicated AC 220V or 110V, 50Hz supply; lab must verify available voltage and circuit capacity before installation.
  • Optional Accessories Not Included: UV sterilization, communication interfaces, USB export, and electronic signature must be ordered separately based on specific workflow needs.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).