Programmable Touchscreen Constant Temperature and Humidity Chamber, 1000 L,-20-100℃
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The unit requires a controlled environment of +5 to 30 °C and an AC 380 V, 50 Hz power supply rated at 8050 W. The balancing-control refrigeration system with multi-point safety protection prevents over-temperature, overload, over-current, fan, and compressor conditions.
- Installation Space Constraint: Confirm installation space against external dimensions of 1060 x 1340 x 1995 mm and keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance.
- Environmental Constraint for Humidity Sensor: The high-temperature humidity sensor for real-time monitoring requires stable ambient conditions within the specified working environment range to maintain accurate humidity control.
- Power Supply Requirement: Prepare the specified AC 380 V, 50 Hz power supply delivering 8050 W, and ensure the unit is connected by a qualified electrician to avoid over-current or electrical hazards.
- Safety Protection System: The independent alarm and protection functions cover over-temperature, overload, over-current, fan, and compressor conditions to maintain dependable low-temperature performance and stable chamber recovery.
- Order-Confirmed Build Constraint: This 1000-size configuration is commonly supplied as an order-confirmed build, so reconfirm specifications before shipment scheduling.
Position the chamber in a controlled environment with adequate space and power supply, then configure the programmable touchscreen controller. The following steps outline safe installation, start-up, and routine operation based on manufacturer guidelines.
Required Equipment: Suitable lifting equipment for unloading and positioning, AC 380 V, 50 Hz power supply with 8050 W capacity, Qualified electrician for power connection
- Prepare Installation Site
Confirm the installation space against external dimensions of 1060 x 1340 x 1995 mm, ensuring air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance. - Unpack and Position Chamber
Keep the packed chamber upright during transport, then use suitable lifting equipment to unload and position the unit in the prepared location. - Connect Power Supply
Connect the chamber to the specified AC 380 V, 50 Hz power supply delivering 8050 W via a qualified electrician to ensure proper grounding and avoid over-current conditions. - Configure the Touchscreen Controller
Set up the programmable color touchscreen controller with curve display and multi-language interface, programming up to 100 programs, 1000 segments, and 999 cycle steps as needed. - Set Environmental Parameters
Enter the desired temperature range (-20 to 100 °C) and humidity range (35% to 95% RH) via the controller, ensuring the PID auto-tuning function activates to correct deviations. - Verify Safety Systems
Confirm the independent alarm and protection functions for over-temperature, overload, over-current, fan, and compressor conditions are operational before starting the chamber. - Load Samples and Begin Operation
Place samples on the provided 4 shelves, close the door securely, and start the programmed cycle, monitoring real-time curves on the touchscreen display.
How does the temperature uniformity vary between high-temperature and low-temperature operation in this chamber?
Temperature fluctuation/uniformity is specified as ±0.5°C at high temperature and ±1°C at low temperature. This means that samples subjected to low-temperature conditions may experience larger spatial temperature variations, which should be considered for sensitive incubation or stability studies that require tight thermal homogeneity.
What are the power supply requirements for this 1000 L chamber, and can it be adapted to common laboratory electrical systems?
The chamber requires an AC 380 V, 50 Hz power supply with a rated power of 8050 W. This is a three-phase industrial voltage; laboratories with 208 V or 240 V single-phase supplies would need a transformer or a different configuration. The manufacturer should be consulted for alternative power options before ordering.
What installation and environmental conditions are needed for optimal operation of this humidity chamber?
The unit should be installed in an ambient temperature range of +5 to 30°C with enough space for the external dimensions of 1060 x 1340 x 1995 mm. A dedicated 8050 W, AC 380 V, 50 Hz power supply is required, and air inlets, test ports, drain areas, and the controller must remain accessible. Because this configuration is typically built to order, lead time and final specifications should be confirmed before shipment.
The BPS-1000CA programmable constant temperature and humidity chamber provides 1000 L capacity with -20 to 100 °C and 35–95% RH control, using a balancing-control refrigeration system and imported 304 stainless-steel interior for stable long-duration operation in pharmaceutical, biotechnology, and industrial test environments.
Positive
- Large program capacity for staged methods: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps with per-segment timing up to 99 h 59 min, enabling complex multi-stage environmental test protocols without external sequencing.
- Balancing-control refrigeration with safety protection: The balancing-control refrigeration system combined with multi-point safety protection (over-temperature, overload, over-current, fan, compressor) supports reliable low-temperature performance and stable chamber recovery during repeated use.
Trade-offs
- High power and infrastructure requirements: The chamber requires 8050 W input from an AC 380 V, 50 Hz supply and operates only in a +5 to 30 °C working environment, necessitating dedicated electrical infrastructure and climate-controlled lab space.
- Order-confirmed build requires pre-shipment reconfirmation: This 1000 L configuration is commonly supplied as an order-confirmed build, meaning the exact controller type, lighting form, humidity function, and accessory package must be reconfirmed before shipment scheduling to avoid specification mismatches.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).