Programmable Light Incubator 800 L AF-MBP0800 ATOMFAIR®

$18,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Programmable 800 L LCD light incubator with 4-50°C no-light and 10-50°C illuminated control, 0-30000 lx lighting, 304 stainless interior, 2800 W.

SKU: AF-LE-E-MGLI-0800-BP85
Category:
Brands:

Programmable LCD Light Incubator, 800 L
Research-grade laboratory product
Product Overview

Programmable LCD Light Incubator, 800 L is a LCD light incubator built for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows. This configuration provides 800 l chamber volume, No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C, 0 to 30000 lx, six-step adjustable illumination, 304 stainless-steel chamber interior with removable shelving and lcd microcomputer controller with menu-based operation and large-screen data display for stable day-to-day laboratory operation.

This family uses fluorine-free design, imported compressor and fan components, stainless-steel interior construction, rounded internal corners, adjustable shelf spacing and a left-side test port for measurement access. The chamber combines imported compressor and circulation-fan assembly with microcomputer temperature-control system, 4 shelves and an interior size of 800 x 590 x 1650 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

These LCD models are positioned for laboratories that need stable illuminated incubation with selectable single-side, double-side, three-side or partition lighting, plus optional communication, alarm and atmosphere-related accessories. Installation planning can be based on the external size of 1475 x 890 x 1780 mm and the stated power requirement of 2800 W. Optional functions such as rs232/485 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; light-intensity detection and control system allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MBP0800
Manufacturer Model MGC-850BP
Capacity 800 L
Temperature Control Range No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Lighting Configuration 0 to 30000 LX, six-step adjustable; partition lighting, two levels; Lighting form varies by model and includes single-side, double-side, three-side or partition lighting
Controller LCD microcomputer controller with menu-based operation and large-screen data display
Chamber Material 304 stainless-steel chamber interior with removable shelving
Power / Input 2800 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration microcomputer temperature-control system
Cooling System imported compressor and circulation-fan assembly
Continuous Operation Guidance Recommended for continuous operation schedules of not less than 180 hours under proper installation conditions
Internal Dimensions 800 x 590 x 1650 mm
External Dimensions 1475 x 890 x 1780 mm
Shelves / Light Decks 4 shelves
Program Function Programmable control version for staged lighting and temperature operation
Optional Accessories and Functions RS232/485 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; light-intensity detection and control system
Performance Features
  • LCD menu control and large-screen display keep temperature and lighting values visible during routine laboratory operation. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Fluorine-free cooling design with imported compressor and fan components supports efficient chamber running and long service life. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • 304 stainless-steel interior construction with rounded corners and removable shelving helps improve cleaning efficiency and sample layout flexibility. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Model-specific lighting structures allow the user to match illumination intensity and distribution to cultivation depth and chamber size. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
  • Independent over-temperature alarm protection helps stop the unit and alert users when abnormal temperature conditions occur. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Optional communication, printing, USB storage, CO2 and light-detection functions extend the chamber for documented and application-specific workflows. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
APPLICATION SCOPE: Suitable for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1475 x 890 x 1780 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This incubator requires a stable ambient temperature between 5°C and 30°C and a dedicated 220 V, 50 Hz power supply rated at 2800 W. Continuous operation beyond 180 hours is recommended only under proper installation conditions with adequate ventilation and maintenance access.

  • Temperature Regulation: Maintain the incubator in no-light mode between 4°C and 50°C or in illuminated mode between 10°C and 50°C with a fluctuation of ±1°C.
  • Lighting Configuration: Select illumination intensity from 0 to 30000 lx in six steps and configure partition lighting to match the cultivation depth.
  • Over-Temperature Protection: The independent over-temperature alarm halts operation and alerts users when abnormal temperature conditions occur.
  • Continuous Operation Requirement: Schedule continuous runs for at least 180 hours under proper installation conditions to ensure stable performance.
  • Ambient Temperature Range: Operate the incubator only in an ambient temperature between 5°C and 30°C as specified in the technical specifications.

Follow these steps to position, connect, and configure the incubator for light-controlled incubation. Ensure all safety checks are performed before initiating the first run.

Required Equipment: Lifting equipment

  1. Unpack the incubator
    Unpack the chamber using suitable lifting equipment and keep it upright during transport.
  2. Position the incubator
    Measure the installation space to confirm it accommodates the external dimensions of 1475 x 890 x 1780 mm.
  3. Connect to power supply
    Connect the incubator to a 220 V, 50 Hz power supply rated at 2800 W.
  4. Set temperature and lighting
    Set the desired temperature and lighting parameters using the LCD microcomputer controller menu-based interface.
  5. Program incubation cycles
    Use the controller's programmable function to create staged lighting and temperature cycles for the incubation protocol.

Why is the temperature range different in illuminated mode (10–50 °C) versus no-light mode (4–50 °C) on the Atomfair AF-MBP0800 / MGC-850BP?

The illuminated mode cannot maintain the same low-end temperature as no-light mode because the lighting system adds heat inside the chamber. The manufacturer specifies no-light mode at 4–50 °C and illuminated mode at 10–50 °C, so experiments requiring low temperature and high light must be planned within the illuminated-mode limit.

Can the Atomfair AF-MBP0800 / MGC-850BP light incubator support CO2-dependent or humidified applications?

No active humidity control is stated for this configuration, so it should not be treated as a humidified CO2 incubator. CO2 support is available only through optional accessories—a CO2 inlet and infrared CO2 controller—and the unit is intended for microbial culture, plant cultivation, seed testing, insect rearing, and other light-controlled incubation workflows.

What installation and power infrastructure are required for the Atomfair AF-MBP0800 / MGC-850BP 800 L light incubator?

Install the unit in a +5 to 30 °C working environment with space for its external dimensions of 1475 x 890 x 1780 mm and a dedicated AC 220 V, 50 Hz supply rated for the stated 2800 W input. Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance, and keep the packed chamber upright with suitable lifting equipment during unloading and positioning.

The Atomfair AF-MBP0800 (MGC-850BP) is an 800 L programmable light incubator with 304 stainless-steel interior, fluorine-free cooling, and LCD control, supporting light-controlled incubation from 4 to 50°C with up to 30000 lx six-step adjustable illumination, but lacks built-in humidity control and requires careful installation for long-term continuous operation.

Positive

  • 304 stainless-steel interior with rounded corners: The chamber interior is constructed from 304 stainless steel with rounded corners and removable shelving, improving cleaning efficiency and sample layout flexibility in long-duration laboratory use.
  • Fluorine-free cooling with imported compressor: The fluorine-free cooling design uses an imported compressor and circulation-fan assembly, supporting efficient chamber running and stable low-temperature performance during repeated use.

Trade-offs

  • No active humidity control: The base configuration does not include active humidity control, limiting its use for applications requiring precise humidity regulation.
  • Continuous operation guidance: The manufacturer recommends continuous operation schedules of not less than 180 hours under proper installation conditions, which may impose operational planning constraints.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.