Programmable Touchscreen Constant Temperature and Humidity Chamber, 50 L,-20-100℃
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The programmable touchscreen constant temperature and humidity chamber requires a stable AC 220V 50Hz power supply and an ambient temperature range of +5 to 30°C for reliable operation. The unit must be kept upright during transport and positioned using suitable lifting equipment to prevent damage to the refrigeration system and internal components.
- Power Supply Requirement: The chamber requires a dedicated AC 220V 50Hz power supply with a rated input of 2250 W to operate safely.
- Operating Environment Constraint: The chamber must be installed in a location with an ambient temperature between +5°C and 30°C to ensure proper temperature and humidity control.
- Transport and Handling Requirement: The chamber must be kept upright during transport and positioned using suitable lifting equipment to avoid damage to the refrigeration system.
- Installation and Maintenance Access: Air inlets, test ports, drainage areas, and controller surfaces must remain accessible for cleaning and routine maintenance.
The programmable touchscreen constant temperature and humidity chamber requires careful installation and setup to ensure safe and reliable operation. Follow these steps to unpack, position, and initialize the unit for laboratory use.
Required Equipment: Lifting equipment (e.g., forklift or pallet jack)
- Inspect packaging and prepare for unloading
Inspect the reinforced packaging for damage and keep the chamber upright during unloading using suitable lifting equipment. - Confirm installation space
Measure the installation area to ensure it accommodates the external dimensions of 720 x 620 x 725 mm with adequate clearance for air inlets and maintenance access. - Connect power supply
Connect the chamber to a dedicated AC 220V 50Hz power supply with a minimum capacity of 2250 W, and verify that the ambient temperature is within +5°C to 30°C. - Set operating parameters
Turn on the chamber and use the color touchscreen controller to program the desired temperature and humidity parameters, allowing the chamber to stabilize before loading samples. - Verify safety systems
Confirm that the independent alarm and protection functions for over-temperature, overload, over-current, fan, and compressor are operational before starting long-duration tests.
What is the temperature uniformity specification for the Atomfair BPS-50CA chamber at low temperatures compared to high temperatures?
The temperature fluctuation/uniformity is ±0.5°C at high temperatures and ±1°C at low temperatures. This difference is attributed to the balancing-control refrigeration system and the chamber's construction, as stated in the technical specifications for the 50 L, -20 to 100°C model.
What are the ambient operating temperature requirements for the Atomfair BPS-50CA humidity chamber?
The chamber requires a working environment of +5 to 30°C for proper operation of the refrigeration and humidity control systems. Additionally, the power supply must be AC 220V, 50Hz, 2250W, as specified in the technical specifications, and the installation space should accommodate the external dimensions of 720 x 620 x 725 mm.
What is the program capacity of the programmable touchscreen controller in the Atomfair BPS-50CA chamber?
The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps, with a maximum time setting of 99 hours 59 minutes per segment. This large program capacity enables staged environmental methods and repeatable laboratory workflows that require cycle-based control, as detailed in the product's performance features.
The BPS-50CA (AF-BCA0050) is a 50 L programmable touchscreen constant temperature and humidity chamber with a -20 to 100 °C range and 35% to 95% RH control, featuring a balancing-control refrigeration system and imported 304 stainless-steel interior for laboratory incubation, stability testing, and climate simulation.
Positive
- Large program capacity for staged methods: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps, enabling complex, repeatable environmental profiles for long-duration stability studies and accelerated aging tests.
- Balancing-control refrigeration with PID auto-tuning: The balancing-control system combined with PID auto-tuning provides stable temperature and humidity recovery, critical for humidity-sensitive incubation and conditioning applications where deviation must be minimized.
Trade-offs
- Narrow working environment temperature range: The chamber requires an ambient working environment of +5 to 30 °C, which may necessitate additional climate control in laboratories without stable HVAC, particularly during summer or in unconditioned spaces.
- Power supply and installation constraints: The unit requires AC 220 V, 50 Hz at 2250 W, and external dimensions of 720 x 620 x 725 mm demand careful space planning; optional accessories like printers or RS485 must be specified at order, limiting post-purchase upgrade flexibility.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.