Programmable 247 L climate chamber with 5-60 °C no-light control, 10-60 °C illuminated control, 50-90%RH humidity, 0-10000 lux lighting and 800 W input. Order now.

SKU: AF-LE-E-QHXT-0247-250T
Category:
Brands:

Programmable Climate Chamber, 247 L
Research-grade laboratory product
Product Overview

Programmable Climate Chamber, 247 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 247 l of usable space, No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C, 50%rh to 90%rh humidity control and 0 to 10000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet uses top lighting, a visible glass inner door and a cleanable stainless-steel chamber to support both observation and repeatable environmental control. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and top lighting, with an internal working room of 500 x 550 x 900 mm and an external footprint of 740 x 705 x 1560 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series is designed to simulate natural climate conditions with programmable temperature, light and humidity control for plant and biological experiments. The stated input power is 800 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-QHX250T
Capacity 247 L
Temperature Control Range No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 2 C
Humidity Range 50%RH to 90%RH
Humidity Deviation +/- 8%RH
Light Intensity 0 to 10000 Lux (6 levels)
Lighting Faces 2 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 800 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 500 x 550 x 900 mm
External Dimensions 740 x 705 x 1560 mm
Net Weight 106.5 Kg
Shelves / Trays 2 shelves
Program Function Programmable temperature, light, humidity and time control
Configuration Note When set temperature is 10 C or below, ambient temperature should not exceed 26 C; when temperature setpoint is above 40 C, humidity setpoint should generally not exceed 80%
Optional Accessories and Functions RS485/232 interface and communication software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; CO2 controller; light-intensity detection and control system
Performance Features
  • Programmable control of temperature, light, humidity and time supports simulated natural-climate workflows. This is useful for cultivation, conditioning and biological workflows that need moisture control.
  • The top lighting structure is useful for germination and plant-growth experiments. This supports repeatable plant-growth and photoperiod experiments.
  • Self-diagnosis, over-temperature self-limiting and power-off memory help protect the chamber and the samples. This helps preserve operation settings after power interruptions.
  • The embedded screen and menu-style operation make multi-parameter control easy to follow. This supports more reliable day-to-day chamber use.
  • Mirror-finish stainless-steel surfaces and a glass inner door support visibility and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Multiple optional interfaces and atmosphere accessories extend the chamber to more advanced test methods. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber away from direct heat sources, maintain stable room temperature and confirm the selected accessory package before installation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. When the temperature setpoint is above 40 C, humidity setpoints should generally not exceed 80%. Performance notes are based on no-load testing at 20 C and 50%RH ambient humidity. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The Programmable Climate Chamber requires specific ambient conditions for safe and reliable operation. When the set temperature is 10°C or below, ambient temperature must not exceed 26°C, and humidity setpoints should not exceed 80% when the temperature setpoint is above 40°C.

  • Ambient temperature limit at low setpoints: Ambient temperature must not exceed 26°C when the chamber set temperature is 10°C or below.
  • Humidity setpoint limit at high temperatures: When the chamber setpoint is above 40°C, the humidity setpoint should generally not exceed 80%.
  • Stable room temperature requirement: Maintain a stable room temperature to ensure consistent chamber performance and avoid heat sources.
  • Upright positioning during transport: Keep the unit upright during unloading and positioning to prevent damage to the refrigeration system.
  • Power supply specification: Connect the chamber to a grounded AC220V 50Hz power supply as specified in the technical specifications.

Position the chamber away from direct heat sources on a stable, level surface. Confirm the selected accessory package before installation and keep the unit upright during unloading.

Required Equipment: Programmable Climate Chamber, 247 L

  1. Position the chamber
    Place the chamber away from direct heat sources on a stable, level surface with adequate ventilation.
  2. Maintain stable room temperature
    Ensure the room temperature is stable, especially when the set temperature is 10°C or below, to avoid exceeding 26°C ambient.
  3. Confirm accessory package
    Verify and confirm the selected accessory package, such as RS485 interface or CO2 inlet, before installation.
  4. Unload and position the unit
    Keep the chamber upright during unloading and positioning to prevent damage to internal components.
  5. Set environmental parameters
    Use the LCD controller to set the desired temperature, humidity, and light intensity within the specified ranges.
  6. Verify humidity limits
    Confirm that the humidity setpoint does not exceed 80% when the temperature setpoint is above 40°C.

Why does the programmable climate chamber have different temperature ranges in no-light versus illuminated mode?

The specified temperature range depends on illumination mode: no-light mode supports 5 to 60 C, while illuminated mode supports 10 to 60 C. If your protocol requires temperatures below 10 C, run the chamber without illumination; for illuminated plant-growth or photoperiod experiments, plan for a minimum of 10 C. Humidity control is specified at 50%RH to 90%RH with ±8%RH deviation.

Can the AF-QHX250T climate chamber be integrated with external data logging, CO2 control, or alarm systems?

Yes. Optional accessories include an RS485/232 interface and communication software, embedded printer, USB data storage, wireless alarm system, CO2 inlet, CO2 controller, and light-intensity detection and control system. These options extend the chamber for advanced test methods without changing the base programmable temperature, light, humidity, and time control.

What installation and ambient conditions are required for reliable low-temperature operation of this chamber?

When the set temperature is 10 C or below, ambient temperature should not exceed 26 C; when the setpoint is above 40 C, humidity setpoints should generally not exceed 80%. Performance specifications are based on no-load testing at 20 C and 50%RH ambient humidity. The chamber requires an AC220V 50Hz supply with 800 W input; keep it away from direct heat sources, maintain stable room temperature, and keep the unit upright during unloading and positioning.

The Programmable Climate Chamber (247 L) offers programmable control of temperature, humidity, and light with a top-lighting configuration and stainless-steel interior, making it suitable for plant growth, tissue culture, and biological experiments. However, its operational range is limited by ambient temperature restrictions when set below 10°C and by reduced humidity capability above 40°C.

Positive

  • Programmable multi-parameter control: The LCD microcomputer controller enables programmable temperature, humidity, light, and time settings, supporting simulated natural-climate workflows for cultivation and biological assays.
  • Top lighting for plant growth: The top-mounted, six-level LED illumination (0–10000 lux) provides uniform, shadow-free light exposure for germination and photoperiod experiments without obstructing internal shelf space.

Trade-offs

  • Ambient temperature constraint at low setpoints: When the set temperature is 10°C or below, the ambient room temperature must not exceed 26°C, limiting placement in unconditioned or warm laboratory environments.
  • Reduced humidity at high temperature setpoints: At temperature setpoints above 40°C, the humidity setpoint should generally not exceed 80% RH, restricting combined high-temperature and high-humidity testing protocols.