Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

98 L anti-static nitrogen moistureproof cabinet with 1%-60% RH control, 448 × 400 × 688 mm body, 3 shelves, and ≥50% nitrogen savings. Order now.

SKU: AF-EI-E-MNIC-ESD0-098L
Category:
Brands:

98L Moistureproof Nitrogen Integrated Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 98 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 448 × 400 × 688 mm, inner dimensions of 446 × 372 × 598 mm and 3 adjustable shelves.

This moistureproof nitrogen integrated cabinet combines electronic dehumidification with nitrogen control in one storage platform for efficient low-humidity recovery. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability while lowering gas demand compared with ordinary nitrogen-only cabinet operation.

Typical application areas include research laboratories, electronics workshops, optical storage rooms, incoming-material control areas, powder and film storage spaces and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, an electronic dehumidification core with regenerative absorbent polymer, a precision nitrogen-control device, fully automatic switching between system modes and display-based cabinet management for dependable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-MNIC98F
Product Family Moistureproof Nitrogen Integrated Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 98 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 448 × 400 × 688 mm
Inner Dimensions (W × D × H) 446 × 372 × 598 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic switching between dehumidification and nitrogen-control modes
Dehumidification System Electronic dehumidification core with regenerative absorbent polymer
Dehumidification Module Housing ABS plus flame-retardant housing
Nitrogen Control System Precision nitrogen-control device for rapid cabinet humidity reduction
Integrated Efficiency Designed to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets
Suitable Stored Materials Moisture-sensitive electronic parts, optical components, powders, films and laboratory materials

Key Features and Advantages

  • Integrated dual-system architecture combining an electronic dehumidification core with a precision nitrogen-control device.
  • High-performance absorbent polymer and regenerative dehumidification design for repeat-use moisture control.
  • ABS plus flame-retardant housing on the dehumidification module for durable routine cabinet operation.
  • Fully automatic switching logic between dehumidification and nitrogen-control modes according to cabinet humidity conditions.
  • Integrated cabinet design intended to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, incoming-material control areas, powder and film storage rooms and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires stable indoor installation with verified leveling and door sealing to ensure proper humidity control. Utility connections for power and nitrogen gas must be confirmed before operation, and shelf loading must not exceed specified limits.

  • Stable Surface Installation: Install the cabinet on a stable, level indoor surface to prevent tipping and ensure proper sealing.
  • Door Sealing: Verify that the tempered-glass door seals properly after installation to maintain the low-humidity environment.
  • Even Load Distribution: Distribute stored items evenly across the three adjustable shelves to avoid overloading and maintain cabinet stability.
  • Gas Supply Verification: Ensure that the nitrogen gas supply is stable and connected correctly before operating the cabinet.
  • Shelf Loading Limits: Do not exceed the stated shelf-loading conditions to prevent structural damage or performance degradation.

Follow these steps to properly install the cabinet, verify utility connections, and begin safe operation. Adhering to the sequence ensures optimal humidity control and nitrogen efficiency.

Required Equipment:

  1. Inspect Cabinet
    Inspect the cabinet upon delivery for any transit damage or missing components.
  2. Install on Stable Surface
    Install the cabinet on a stable, level indoor surface near power and gas connections.
  3. Verify Gas Supply
    Verify that the nitrogen gas supply is stable and properly connected to the cabinet's nitrogen inlet.
  4. Confirm Utility Connections
    Confirm that power and gas connections meet the cabinet's specified requirements before powering on.
  5. Distribute Items Evenly
    Distribute stored items evenly across the three adjustable shelves to avoid overloading.
  6. Operate with Door Closed
    Keep the cabinet door closed during normal operation to maintain the set humidity level.

How does the integrated dehumidification system affect nitrogen consumption compared to a standalone nitrogen cabinet?

The integrated dual-system architecture reduces nitrogen usage by more than 50% compared with ordinary nitrogen cabinets. The electronic dehumidification core with regenerative absorbent polymer handles baseline moisture removal, so the precision nitrogen-control device is used primarily for rapid humidity reduction, lowering overall gas demand while maintaining efficient low-humidity recovery.

Can the 98L Moistureproof Nitrogen Integrated Cabinet be used for storing optical components or powders alongside ESD-sensitive electronics?

Yes, the cabinet is designed to store moisture-sensitive electronic parts, optical components, powders, films, and laboratory materials. The anti-static cabinet body and exterior coating make it suitable for electrostatic-control areas and ESD-sensitive material handling, while the humidity control range of 1%–60% RH accommodates diverse material requirements.

What are the critical infrastructure requirements for installing the 98L moistureproof nitrogen cabinet?

Install the cabinet on a stable indoor surface with proper power and gas connections, and verify stable gas-supply conditions before operation. The outer dimensions are 448 × 400 × 688 mm, and it includes 3 adjustable shelves. Ensure level installation, door sealing integrity, and do not exceed stated shelf-loading or application conditions.

This 98L moistureproof nitrogen integrated cabinet combines electronic dehumidification with nitrogen purging to achieve 1%-60% RH control, reducing nitrogen consumption by over 50% compared to conventional nitrogen cabinets. The anti-static cabinet body and ESD-safe construction make it suitable for electrostatic-sensitive storage in research and electronics environments.

Positive

  • Integrated dual-system efficiency: Combines electronic dehumidification with nitrogen control to reduce nitrogen usage by more than 50% compared to ordinary nitrogen cabinets, lowering operational gas demand.
  • ESD-safe anti-static construction: Anti-static cabinet body with 1.2 mm galvanized steel and anti-static exterior coating, suitable for electrostatic-control areas and ESD-sensitive material handling.

Trade-offs

  • Requires external nitrogen supply: Operation depends on a stable nitrogen gas supply and power connection; not a standalone dehumidifier without gas infrastructure.
  • Standard cabinet not corrosion-resistant: Standard body is galvanized steel with anti-static coating; for corrosive or cleanroom environments a stainless steel upgrade is needed.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).