Mercury Hg Evaporation Material 99.999% Pure ATOMFAIR®

Price range: $310.00 through $2,600.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

99.999% Mercury (Hg) evaporation material in sealed ampoules, supplied as liquid metal for low-temperature vacuum evaporation; 25g-1kg packs. RFQ only.

Mercury (Hg) Evaporation Material, Sealed ampoule, 99.999%, Liquid metal in sealed ampoule
Product Type: Pure Metal Evaporation Material
Research-grade laboratory product
Product Overview

Mercury (Hg) Evaporation Material, Sealed ampoule, 99.999%, Liquid metal in sealed ampoule is a research-grade pure metal evaporation material supplied as Sealed ampoule with 99.999% material specification and Liquid metal in sealed ampoule size range for vacuum thin-film deposition workflows.

This evaporation material is prepared for laboratory procurement where material identity, purity, physical form, pack size and deposition hardware must be confirmed before ordering. The listed configuration supports selection for Special low-temperature vacuum evaporation; RFQ only using Dedicated sealed low-temperature source / cold trap setup.

Available pack sizes are 25g / 100g / 500g / 1kg. Buyers should confirm deposition source geometry, required quantity, certificate requirements and shipment conditions before quotation.

Performance Features
  • Defined material identity: Mercury (Hg) for clear procurement and deposition-process matching.
  • Specified physical form: Sealed ampoule with Liquid metal in sealed ampoule sizing to support source loading and evaporation review.
  • Purity or composition listed as 99.999%, allowing comparison between standard, high-purity and RFQ-controlled grades.
Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-HGSEA-5NLIQUIDMETALI
Material Mercury
Formula Hg
Product Type Pure Metal Evaporation Material
Form Sealed ampoule
Purity / Composition 99.999%
Particle Size / Dimensions Liquid metal in sealed ampoule
Minimum Order Quantity 25g
Available Pack Sizes 25g / 100g / 500g / 1kg
Indicative Price Tiers 25g: USD 310; 100g: USD 700; 500g: USD 1800; 1kg: USD 2600
Evaporation Source Dedicated sealed low-temperature source / cold trap setup
Evaporation Method Special low-temperature vacuum evaporation; RFQ only
Melting Point -39
Density 13.55
PROCUREMENT CHECK: Confirm model, purity, form, size range, pack size and deposition-source compatibility before quotation.
DOCUMENTATION REVIEW: Certificate, safety data sheet, shipment condition and export requirements can be reviewed against laboratory use requirements.
APPLICATION MATCHING: Evaporation source hardware and process route should be matched to material behavior, melting point and film requirements.
INQUIRY NOTE: Include the required model, purity, form, size range and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For material selection, deposition-source matching, pack-size confirmation or quotation support, contact our technical sales team.
INQUIRY: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This material is supplied as a sealed ampoule containing liquid mercury at 99.999% purity for low-temperature vacuum evaporation. Storage and handling must prevent ampoule rupture and mercury vapor release due to the material's acute toxicity and vapor pressure.

  • Storage Environment: Store sealed ampoules in a cool, dry, well-ventilated area to minimize mercury vapor pressure and prevent thermal stress on the glass.
  • Ampoule Integrity: Inspect the ampoule for any visible cracks or damage before use, and discard if the seal is compromised.
  • Vapor Containment: Use only with a dedicated low-temperature evaporation source equipped with a cold trap to condense and contain mercury vapor during deposition.
  • Personal Protective Equipment: Handle mercury in a fume hood while wearing nitrile gloves, safety goggles, and a lab coat to avoid skin contact and inhalation.
  • Waste Disposal: Collect all mercury waste, including used ampoules and cold trap residues, in sealed containers for hazardous waste disposal.

This procedure describes the safe loading and evaporation of mercury from a sealed ampoule using a dedicated low-temperature source with cold trap. Follow each step precisely to prevent mercury vapor exposure and ensure film quality.

Required Equipment: Dedicated low-temperature evaporation source, Cold trap, Fume hood

  1. Inspect Ampoule
    Inspect the sealed ampoule for any visible cracks or damage before loading into the evaporation source.
  2. Transfer to Source
    Transfer the ampoule to the dedicated low-temperature evaporation source located inside a fume hood.
  3. Activate Cold Trap
    Connect and activate the cold trap, ensuring it reaches the required temperature to condense mercury vapor.
  4. Evacuate Chamber
    Evacuate the deposition chamber to the required vacuum level for low-temperature evaporation.
  5. Heat Source
    Heat the evaporation source to the temperature appropriate for mercury based on its melting point of -39°C and vapor pressure characteristics.
  6. Deposit Film
    Deposit the mercury film onto the substrate while monitoring the cold trap temperature and deposition rate.
  7. Cool and Vent
    Allow the system to cool completely and safely vent the chamber before removing the substrate and disposing of the ampoule residue.

What is the significance of the -39°C melting point for mercury evaporation material in thin-film deposition?

Mercury has a melting point of -39°C as specified in the technical data table for this AF-HGSEA-5NLIQUIDMETALI product. This means it remains liquid at standard laboratory temperatures and requires special low-temperature vacuum evaporation using a dedicated sealed low-temperature source with a cold trap setup to prevent uncontrolled vapor release and ensure film uniformity. The liquid metal form in a sealed ampoule demands careful handling to avoid breakage and exposure during loading.

What deposition hardware is required for evaporating mercury from this sealed ampoule?

This mercury evaporation material requires a dedicated sealed low-temperature source combined with a cold trap setup for safe operation. The evaporation method is classified as special low-temperature vacuum evaporation available only by RFQ (request for quotation). Standard thermal or e-beam sources are not compatible due to mercury's low melting point (-39°C) and high toxicity; buyers must confirm deposition-source compatibility before ordering.

How should mercury evaporation material be stored and handled given its liquid metal form?

The material is supplied as liquid mercury in a sealed ampoule with 99.999% purity. Because mercury is liquid at room temperature (melting point -39°C) and highly toxic via inhalation or skin contact, it must remain in its original sealed ampoule until use inside a dedicated low-temperature evaporation system with cold trap containment. The procurement checklist advises reviewing safety data sheets and shipment conditions before ordering; handling requires fume hoods and appropriate personal protective equipment.

Mercury (Hg) evaporation material at 99.999% purity in sealed ampoule form, requiring dedicated low-temperature evaporation source with cold trap setup. Suitable for specialized thin-film deposition where high purity and controlled evaporation are critical.

Positive

  • Ultra-high purity (99.999%): Reduces contamination risk in thin-film deposition, enabling reproducible film properties for research-grade applications.
  • Sealed ampoule containment: Prevents oxidation and atmospheric exposure, maintaining material integrity and safe handling until deposition.

Trade-offs

  • Dedicated cold trap and source required: Operates only with a dedicated sealed low-temperature source and cold trap setup, limiting compatibility with standard evaporation hardware.
  • RFQ-only procurement process: Evaporation method is special low-temperature vacuum evaporation; RFQ only, adding lead time and requiring pre-quotation confirmation of source geometry and safety protocols.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Package

25g, 100g, 500g, 1kg

Related Products