Low-Temperature Incubator 250L -20-65°C Research ATOMFAIR®

$5,700.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

250L low-temperature incubator with -20-65℃ range, 0.1°C resolution, 3 shelves, and AC220V 50Hz power for research-grade culture control. Order now.

250L Low-Temperature Incubator, -20-65℃ Temperature Control Range
Research-grade laboratory product
Product Overview

250L Low-Temperature Incubator, -20-65℃ Temperature Control Range is designed for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and temperature-controlled holding. With a nominal capacity of 250 L and a temperature range of -20-65℃, it supports controlled handling of cultures, fungal samples, microorganisms, preserved materials, and other laboratory test loads.

The cabinet layout is defined by the chamber size is 600×500×830mm, overall dimensions are 740×900×1580mm, the standard shelf setup is 3 shelves, input power is 1600 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±1.0°C fluctuation control, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Cooling configurations use a compressor and circulation fan with an environmentally oriented refrigerant and airflow circulation system. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-LI250-CA20: Microcomputer liquid-crystal temperature controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Low-Temperature Incubator
Nominal Capacity 250 L
Atomfair Models AF-LI250-CA20
Temperature Range -20-65℃
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±1.0°C
Input Power 1600 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 35°C
Chamber Size 600×500×830mm
Overall Dimensions 740×900×1580mm
Shelves 3 shelves
Timer 0 to 5999 min
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Cooling configurations use a compressor and circulation fan with an environmentally oriented refrigerant and airflow circulation system.
Controller Configuration AF-LI250-CA20: Microcomputer liquid-crystal temperature controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±1.0°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Sub-ambient temperature options extend the usable application range into preservation, low-temperature incubation, and stability tasks that ordinary incubators may not cover.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and holding tasks that require cooling capability beyond a standard constant-temperature incubator.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

Operation requires a stable ambient temperature between +5 and 35°C and a dedicated AC220V 50Hz power supply. The stainless steel chamber with rounded corners should be cleaned with non-abrasive agents to prevent corrosion and maintain hygienic conditions.

  • Temperature Fluctuation Limits: The incubator maintains temperature fluctuation within ±0.5°C at high temperature and ±1.0°C at low temperature, requiring minimal door openings during operation.
  • Power Supply Requirements: Connect the unit to a grounded AC220V 50Hz power outlet capable of supplying 1600W continuously.
  • Ambient Temperature Constraints: The ambient temperature must be maintained between +5 and 35°C to ensure proper cooling and heating performance.
  • Chamber Cleaning Protocol: Clean the mirror stainless steel chamber using non-abrasive, mild cleaning agents and soft cloths to prevent surface damage.
  • Timer Operation Limit: The built-in timer allows programming from 0 to 5999 minutes for timed incubation or holding cycles.

This incubator provides controlled temperature from -20 to 65°C for cultivation and preservation. Follow these steps to set up and run a typical incubation cycle.

Required Equipment:

  1. Place Incubator
    Verify that the incubator is placed on a level surface within the ambient temperature range of +5 to 35°C.
  2. Connect Power
    Connect the power cord to a grounded AC220V 50Hz electrical outlet.
  3. Set Temperature
    Set the desired temperature setpoint using the microcomputer liquid-crystal controller interface.
  4. Load Samples
    Arrange the included shelves to accommodate sample containers and load the samples.
  5. Program Timer
    Program the timer for the required incubation duration, up to 5999 minutes, and start the cycle.

What is the temperature fluctuation tolerance for the 250L low-temperature incubator at high versus low setpoints?

The incubator specifies a temperature fluctuation of ±0.5°C at high temperatures and ±1.0°C at low temperatures, with a resolution of 0.1°C. This asymmetry reflects the greater thermal control challenge when operating below ambient, particularly during compressor cycling at sub-zero setpoints.

Can the 250L low-temperature incubator be integrated with external data logging or remote monitoring systems?

Yes, optional RS485 communication and USB data transfer interfaces are available for selected configurations, enabling external recording of temperature changes. An embedded printer accessory is also offered for on-site logging. These options require lead time and should be confirmed before ordering.

What are the electrical and footprint requirements for installing this 250L low-temperature incubator?

The unit requires an AC220V 50Hz power supply with 1600 W input power. Overall dimensions are 740×900×1580 mm, and the chamber measures 600×500×830 mm. The ambient operating temperature range is +5 to 35°C, so the unit should be placed in a climate-controlled laboratory space to maintain rated performance.

The 250L low-temperature incubator (SKU AF-LE-E-LTIN-0250-2CA5) provides a -20 °C to 65 °C range and 0.1 °C resolution, with temperature fluctuation of ±0.5 °C at high setpoints and ±1.0 °C at low setpoints, making it suitable for sub-ambient cultivation, preservation, and stability testing; however, its 1600 W power draw and required AC220V 50 Hz supply impose specific electrical infrastructure needs, and the 600×500×830 mm chamber with 3 standard shelves limits scalable throughput without accessory reconfiguration.

Positive

  • Sub-ambient temperature control range: The -20 °C to 65 °C range extends usability into low-temperature incubation, sample preservation, and stability testing tasks that typical constant-temperature incubators cannot support, broadening application scope beyond near-ambient-only operation.
  • 0.1 °C temperature resolution with bidirectional fluctuation: The 0.1 °C resolution and published fluctuation of ±0.5 °C (high temp) and ±1.0 °C (low temp) provide finer setpoint granularity and repeatable chamber conditions for routine cultivation and method development, enabling tighter experimental control across the full range.

Trade-offs

  • High continuous power draw and single-phase supply dependency: The 1600 W input power and AC220V 50 Hz power supply requirement demand dedicated electrical infrastructure; facilities without compatible 220 V circuits at 50 Hz may need additional line conditioning or transformer installations, increasing deployment complexity.
  • Time-limited operation and ambient temperature sensitivity: The built-in timer operates only to 5999 min, restricting unattended long-duration incubations without manual reinitiation; the specified +5 to 35°C ambient temperature range limits placement in unconditioned or hot laboratory environments, potentially requiring climate-controlled room space.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).