HiPette-LTS Single-Channel 5-50 μL Pipette ATOMFAIR®

$88.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable single-channel HiPette-LTS pipette, 5-50 μL range with 0.05 μL increments and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HPLT-E050-SC00
Category: ,
Tags:
Brands:

Description

HiPette-LTS Single-channel 5-50 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS Single-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 5-50 µL working range, 0.05 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 5-50 µL with 0.05 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-5-50-µL
Product Family HiPette-LTS
Channel count Single-channel
Volume range 5-50 µL
Increment 0.05 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error At 50 µL: ±0.45 µL (±0.9%); at 25 µL: ±0.35 µL (±1.4%); at 5 µL: ±0.15 µL (±3.0%)
Random error At 50 µL: ±0.15 µL (±0.3%); at 25 µL: ±0.20 µL (±0.8%); at 5 µL: ±0.08 µL (±1.6%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette must be calibrated according to ISO 8655-2 to maintain specified accuracy. It is fully autoclavable for sterilization between uses.

  • Calibration Requirements: Calibration must be performed at the three test volumes (50, 25, and 5 µL) to verify that systematic and random error remain within the specified limits.
  • Tip Compatibility: Only compatible pipette tips should be used to ensure proper sealing and accuracy; incompatible tips may cause leakage or inaccurate volume delivery.

How does the systematic error of the HiPette-LTS 5-50 µL pipette vary across its volume range, and what is the trade-off between accuracy at high versus low volumes?

Systematic error increases significantly at lower volumes: at 50 µL it is ±0.45 µL (±0.9%), at 25 µL ±0.35 µL (±1.4%), and at 5 µL ±0.15 µL (±3.0%). This means the percentage error is three times higher at 5 µL than at 50 µL, a trade-off that should be considered when planning assays requiring high precision near the lower end of the range.

What calibration standard does the HiPette-LTS 5-50 µL pipette adhere to, and what are the implications for integration into ISO-compliant laboratory workflows?

The pipette includes a user calibration reference per ISO 8655-2, as indicated in the technical table. This ensures compatibility with laboratories that require traceable calibration documentation for method validation, but users must perform their own calibration checks using the referenced standard to maintain ISO compliance.

What are the autoclaving requirements for the HiPette-LTS 5-50 µL pipette, and are there any restrictions on the number of sterilization cycles?

The pipette is described as fully autoclavable, but the product description does not specify maximum cycle count or exact autoclave parameters. Standard laboratory practice for fully autoclavable pipettes is typically 121°C for 20 minutes; for validated cycle limits and long-term performance, contact Atomfair technical support.

The HiPette-LTS single-channel 5-50 µL pipette provides full autoclavability and good repeatability at higher volumes, but its systematic error increases substantially at the lower end of the range, making it best suited for mid-to-high volume transfers where precision is less critical.

Positive

  • Fully autoclavable design: The entire pipette can be autoclaved at 121°C, enabling thorough sterilization between uses to prevent cross-contamination in sensitive workflows.
  • Low random error at full volume: At 50 µL, random error is ±0.15 µL (±0.3%), ensuring excellent repeatability for routine transfer and assay setup.

Trade-offs

  • High systematic error at low volume: At 5 µL, systematic error reaches ±0.15 µL (±3.0%), significantly reducing accuracy for low-volume applications and requiring careful volume selection.
  • Calibration and tip dependency: The user must verify calibration per ISO 8655-2 and ensure compatibility with selected tips to maintain specified performance, adding pre-use validation steps.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).