Four-Sided Programmable Climate Chamber 598 L ATOMFAIR®

$7,200.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

598 L programmable climate chamber with 5–60 °C control, 50–90%RH humidity, four-sided 0–18000 lux lighting and 1300 W for plant-growth studies. Order now.

SKU: AF-LE-E-QHXF-0598-600F
Category:
Brands:

Four-Sided Programmable Climate Chamber, 598 L
Research-grade laboratory product
Product Overview

Four-Sided Programmable Climate Chamber, 598 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 598 l of usable space, 5 to 60 C, 50%rh to 90%rh humidity control and 0 to 18000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet combines a visible glass inner door, cleanable stainless-steel surfaces and a high-light four-side illumination layout for demanding plant-growth work. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and four-sided lighting, with an internal working room of 680 x 800 x 1100 mm and an external footprint of 950 x 1140 x 1920 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The four-sided lighting configuration gives a stronger illumination environment for cultivation and photoresponse tests while keeping the same programmable climate-control framework. The stated input power is 1300 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-QHX600F
Capacity 598 L
Temperature Control Range 5 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 1 C
Humidity Range 50%RH to 90%RH
Humidity Deviation +/- 8%RH
Light Intensity 0 to 18000 Lux (6 levels)
Lighting Faces 4 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 1300 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 680 x 800 x 1100 mm
External Dimensions 950 x 1140 x 1920 mm
Net Weight 266 Kg
Shelves / Trays 2 shelves
Program Function Programmable temperature, light, humidity and time control
Configuration Note When set temperature is 10 C or below, ambient temperature should not exceed 26 C; performance data are measured under no-load conditions, ambient temperature 20 C and ambient humidity 50%RH
Optional Accessories and Functions RS485/232 interface and communication software; liquid crystal program controller; wireless alarm system; embedded printer
Performance Features
  • Four-sided illumination supports stronger and more even exposure for plant-growth work. This supports repeatable plant-growth and photoperiod experiments.
  • Programmable climate control helps coordinate temperature, light and humidity in one chamber. This is useful for cultivation, conditioning and biological workflows that need moisture control.
  • Mirror-finish stainless-steel surfaces and a glass inner door support observation and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Liquid crystal program control makes multi-step cycles easier to edit and review. This supports staged testing and repeatable control curves.
  • Wireless alarm, printer and communication options help document the process. This helps protect samples and alerts operators when abnormal conditions occur.
  • The family is suitable for experiments that need stronger lighting than the standard climate-chamber version. This supports repeatable plant-growth and photoperiod experiments.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber level, maintain stable ambient conditions and confirm the chosen control and accessory package before installation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. Performance notes are based on no-load testing at 20 C and 50%RH ambient humidity. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires specific environmental and electrical conditions to ensure safe and accurate operation. Key constraints include ambient temperature limits when operating at low set points, the need for level and upright handling, and a dedicated AC220V 50Hz power supply.

  • Ambient Temperature Limit for Low Set Points: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain performance.
  • Upright Transport and Level Installation: The chamber must be kept upright during transport and positioned on a level surface to prevent internal damage.
  • Electrical Supply Requirements: The chamber requires a dedicated AC220V 50Hz power supply with proper grounding and capacity for 1300W continuous load.
  • No-Load Performance Validation: Performance specifications are validated under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity.
  • Floor Loading Capacity: The chamber's net weight of 266 kg requires a floor that can support the static load without deformation.

This procedure describes the essential steps for unpacking, positioning, and powering the climate chamber. Proper installation ensures safe operation and accurate environmental control.

  1. Unpack and Position
    Unload the chamber from its shipping crate using a forklift or pallet jack, keeping the unit upright at all times.
  2. Level the Chamber
    Place a spirit level on the chamber floor and adjust the leveling feet until the bubble is centered.
  3. Connect Power
    Connect the chamber to a properly grounded AC220V 50Hz power outlet with sufficient capacity for the 1300W load.
  4. Configure Environmental Conditions
    Verify that the ambient temperature is within the required range for the intended set point, especially when setting temperatures below 10°C.

What ambient temperature limit must be maintained when the AF-QHX600F climate chamber is set to 10°C or below?

When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. This requirement is specified in the product's configuration notes to ensure proper operation. Performance data are measured under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity.

Can the AF-QHX600F four-sided climate chamber be integrated with external data logging or remote monitoring systems?

Yes, the chamber supports optional RS485/232 interface and communication software, as well as a wireless alarm system and an embedded printer. These accessories enable remote monitoring, data logging, and alarm notification, making it suitable for documentation and sample protection.

What are the critical installation and handling requirements for the 598 L four-sided climate chamber?

The chamber must be kept level during installation and transported upright with reinforced packaging. It requires a stable ambient environment, and the power supply is AC220V 50Hz with 1300W input. The external dimensions are 950 x 1140 x 1920 mm and net weight is 266 kg, so floor loading and access should be confirmed before installation.

The AF-QHX600F 598 L four-sided programmable climate chamber integrates 5 to 60 C temperature control, 50 to 90%RH humidity control, and 0 to 18000 lux four-sided illumination in a stainless-steel interior for plant growth, tissue culture, seed germination, and microbial preservation work; low-temperature setpoints require ambient temperature not exceeding 26 C, and the 266 kg unit needs stable installation and AC220V 50Hz power.

Positive

  • Four-sided high-light illumination: Four-sided lighting provides up to 18000 lux in six levels within the 598 L mirror-finish stainless-steel chamber, supporting stronger and more even exposure for plant-growth and photoperiod experiments.
  • Programmable multi-parameter climate control: The LCD microcomputer controller coordinates temperature (5 to 60 C), humidity (50 to 90%RH), light intensity, and time over programmable multi-step cycles, enabling staged cultivation and repeatable control curves.

Trade-offs

  • Low-temperature ambient ceiling: When the set temperature is 10 C or below, ambient temperature must not exceed 26 C; quoted performance is based on no-load testing at 20 C ambient temperature and 50%RH ambient humidity.
  • Installation and utility demands: The chamber requires AC220V 50Hz power at 1300 W input, weighs 266 kg, and occupies a 950 x 1140 x 1920 mm footprint; it must be kept level, kept upright during unloading, and placed in stable ambient conditions.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).