Four-Sided Programmable Climate Chamber, 429 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires stable ambient conditions and a dedicated power supply to maintain specified performance. When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to prevent operational issues.
- Ambient temperature constraint: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
- Performance validation conditions: All performance data are measured under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity.
- Installation requirements: The unit must be kept level on a stable surface with adequate clearance for ventilation and door operation.
- Power supply specification: The chamber requires a 1200W, AC220V 50Hz power supply with proper grounding.
- Transport and handling: The chamber must be transported upright and unpacked with care to avoid damage to internal components.
This procedure outlines the necessary steps for safely installing and initializing the climate chamber. Following these steps ensures proper operation and adherence to the chamber's environmental constraints.
- Unload upright
Keep the chamber upright during unloading and positioning to prevent damage to the refrigeration system and glass door. - Position level
Place the chamber on a level surface and ensure stable ambient conditions with adequate clearance for airflow. - Confirm configuration
Confirm the selected control and accessory package before installation to ensure correct setup. - Connect power
Connect the chamber to a dedicated AC220V 50Hz power supply capable of 1200W continuous load. - Verify ambient temperature
If the set temperature is 10°C or below, verify the ambient temperature does not exceed 26°C to maintain performance.
What is the practical humidity control accuracy of the AF-QHX460F climate chamber, and how does the specified ±8%RH deviation affect experiments requiring tight moisture regulation?
The chamber's humidity control range is 50%RH to 90%RH with a deviation of ±8%RH. This means that at a setpoint of 70%RH, the actual humidity may vary between 62% and 78%RH. Users should anticipate this tolerance when designing experiments that require precise humidity stability, particularly for long-term plant growth or material testing where moisture levels are critical. The specification is stated under no-load conditions at 20°C and 50%RH ambient humidity.
Can the four-sided programmable climate chamber be integrated with external data logging or monitoring systems for remote experiment tracking?
Yes, the chamber supports optional RS485/232 interface and communication software, allowing integration with external data logging and monitoring systems. Additionally, an optional wireless alarm system and embedded printer are available for real-time alerts and documentation. These accessories must be specified at the time of configuration, as they are not included by default.
What are the critical ambient temperature limitations when operating the chamber at low set temperatures, and how does this affect laboratory placement?
When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain performance. This is a critical operational constraint that limits placement in labs with high ambient temperatures or near heat sources. The chamber's performance data are measured under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity, so deviations from these conditions may affect actual performance. Users should ensure adequate environmental control in the lab, especially for cooling applications.
The AF-QHX460F four-sided programmable climate chamber provides 429 L of conditioned space with coordinated temperature (5–60 °C), humidity (50–90%RH), and six-level illumination up to 18,000 lux, making it well suited for plant-growth and photoresponse work; however, low-temperature set points require ambient temperatures no higher than 26 °C and humidity control is limited to the 50–90%RH band.
Positive
- Four-sided illumination up to 18,000 lux: Four-face lighting delivers 0–18,000 lux in six levels for stronger and more even exposure in plant-growth, photoperiod, and photoresponse experiments.
- Programmable temperature, light, humidity, time: The LCD microcomputer controller coordinates temperature, light, humidity, and time with a 0–9999 min timer range, supporting multi-step climate cycles for cultivation and conditioning workflows.
Trade-offs
- Low-temperature set point ambient limit: When the set temperature is 10 °C or below, ambient temperature must not exceed 26 °C; performance data are measured under no-load conditions at 20 °C and 50%RH ambient humidity.
- Humidity control limited to 50–90%RH: The chamber's humidity range is 50%RH to 90%RH with ±8%RH deviation, so it cannot provide drier conditions for applications requiring sub-50%RH environments.