100L Multi-Chamber Four-Chamber Mold Incubator, 0-60℃ Temperature Control Range
Research-grade laboratory product
Product Overview

100L Multi-Chamber Four-Chamber Mold Incubator, 0-60℃ Temperature Control Range is designed for mold and fungal culture, microorganism observation, constant-temperature storage, and routine environmental incubation. With a nominal capacity of 100 L and a temperature range of 0-60℃, it supports controlled handling of cultures, fungal samples, microorganisms, preserved materials, and other laboratory test loads.

The cabinet layout is defined by the chamber size is 500×450×450mm, overall dimensions are 1300×805×1885mm, the standard shelf setup is 2 shelves per chamber, input power is 4400 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±0.5°C fluctuation control, ±1°C at 25°C temperature uniformity, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-MI100-4BOX: Liquid-crystal display controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Four-Chamber Mold Incubator
Nominal Capacity 100 L
Atomfair Models AF-MI100-4BOX
Temperature Range 0-60℃
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±0.5°C
Temperature Uniformity ±1°C at 25°C
Input Power 4400 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 30°C
Chamber Size 500×450×450mm
Overall Dimensions 1300×805×1885mm
Shelves 2 shelves per chamber
Timer 0 to 5999 min
UV Sterilization Standard
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading.
Controller Configuration AF-MI100-4BOX: Liquid-crystal display controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations; UV sterilization system, standard or optional depending on the selected mold configuration; UV sterilization status for this configuration: Standard. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±0.5°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Temperature uniformity of ±1°C at 25°C helps reduce position-related differences inside the chamber, which is valuable when multiple vessels are loaded at once.
  • The multi-chamber structure improves batch separation, making it easier to run parallel work with less door-opening interference between different sample sets.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for laboratories that need mold or microbial incubation in separated batches, allowing different sample groups to be organized in parallel while reducing unnecessary disturbance between chambers.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

The incubator must be connected to a grounded AC220V 50Hz power supply with a 4400W input and operated within an ambient temperature range of +5 to 30°C. The mirror stainless-steel inner chamber with rounded corners facilitates cleaning and reduces contamination risk during batch incubation.

  • Power Supply Requirement: Connect the incubator to a grounded AC220V 50Hz power outlet capable of supplying 4400W.
  • Ambient Temperature Range: Operate the incubator only within an ambient temperature range of +5 to 30°C to ensure proper temperature control and equipment longevity.
  • Chamber Cleaning and Maintenance: Clean the mirror stainless-steel inner chamber using non-abrasive cleaners to maintain rounded-corner surfaces and prevent cross-contamination.

What are the electrical and installation requirements for the 100L four-chamber mold incubator?

The incubator requires an AC220V 50Hz power supply with an input power of 4400 W. The overall dimensions are 1300×805×1885 mm, and the ambient temperature must be maintained between +5 and 30°C. These specifications allow laboratories to plan for a dedicated circuit, adequate floor space, and appropriate environmental conditions before installation.

Can the 100L four-chamber mold incubator be integrated with external monitoring systems via RS485 communication?

Yes, an optional RS485 communication interface is available for recording temperature changes, enabling integration with external data logging or monitoring systems. Additionally, an optional embedded printer or USB data transfer can be configured for selected setups, though availability and lead time should be confirmed by email before ordering.

Is UV sterilization standard on the 100L four-chamber mold incubator, and how does it support contamination control?

Yes, UV sterilization is standard on this configuration. It is designed to reduce microbial contamination within the mirror stainless-steel inner chamber, which features rounded-corner transitions for easier cleaning. This is particularly relevant for mold and fungal culture applications where maintaining aseptic conditions between batches is critical.

This 100L four-chamber mold incubator provides ±0.5°C temperature fluctuation and ±1°C uniformity at 25°C with a 0-60°C range, enabling controlled batch separation of mold and microbial cultures via independent chambers that minimize door-opening cross-interference during parallel experimental runs.

Positive

  • Multi-chamber batch separation: Four independent 100L chambers allow parallel incubation of different mold or microbial sample sets, reducing thermal and contamination interference from door openings between groups.
  • High uniformity and fine resolution: ±1°C temperature uniformity at 25°C combined with 0.1°C resolution supports reproducible cultivation conditions across multiple vessels per chamber.

Trade-offs

  • High input power requirement: 4400 W input power and AC220V 50Hz supply constrain placement to labs with dedicated high-current circuits, limiting portability and bench-top use.
  • Large footprint and ambient constraints: Overall dimensions of 1300×805×1885mm require significant floor space, and ambient temperature must be maintained between +5 to 30°C for rated performance, restricting siting options.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).