Description
Mini Pipette Single-channel 50 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette is not suitable for high-temperature sterilization and requires calibration per ISO 8655-2 to maintain specified accuracy. Use only compatible tips to ensure proper sealing and volume delivery.
- Sterilization Limitation: The pipette cannot be sterilized by autoclaving and must be cleaned using low-temperature methods.
- Calibration Requirement: User calibration must be performed against ISO 8655-2 reference to verify systematic error within ±0.25 µL and random error within ±0.15 µL at the 50 µL test volume.
- Tip Compatibility: Only tips specifically designed for this pipette model should be used to avoid leakage and inaccurate volume transfer.
- Fixed-Volume Constraint: The pipette delivers a fixed 50 µL volume and cannot be adjusted for other volumes.
How does the fixed volume of 50 µL on the Atomfair Mini Pipette affect its accuracy and precision compared to adjustable pipettes?
The fixed volume eliminates user adjustment variability, delivering consistent systematic error of ±0.25 µL (±0.5%) and random error of ±0.15 µL (±0.3%) at 50 µL as per ISO 8655-2. This ensures high repeatability for single-volume tasks like PCR setup, but the pipette cannot be adjusted for other volumes, unlike adjustable models.
Can the Atomfair Mini Pipette 50 µL be autoclaved for sterilization between uses?
No, the product specification states it is not suitable for high-temperature sterilization. Alternative sterilization methods such as chemical disinfection or UV exposure must be used for aseptic applications.
What calibration standard is used for the Atomfair Mini Pipette 50 µL and what is the recommended calibration interval?
The pipette is calibrated per ISO 8655-2, as indicated in the technical specifications. The product description does not specify a calibration interval; laboratories should follow their own standard operating procedures based on usage frequency and quality assurance requirements.
The Atomfair Mini Pipette Single-channel 50 µL offers fixed-volume dispensing with verified accuracy (±0.5% systematic error) and precision (±0.3% random error) at 50 µL, making it suitable for PCR setup and routine liquid handling. However, it is not autoclavable and is limited to a single fixed volume.
Positive
- Accurate fixed-volume dispensing: Systematic error at 50 µL is ±0.25 µL (±0.5%) and random error is ±0.15 µL (±0.3%), ensuring reliable liquid transfer for routine analytical workflows.
- Suitable for PCR setup: The 50 µL fixed volume is well-suited for single-tube sample preparation, reagent addition, and PCR or qPCR setup.
Trade-offs
- Not autoclavable: The pipette is not suitable for high-temperature sterilization, requiring alternative sterilization methods or single-use tips for aseptic applications.
- Fixed volume limitation: The 50 µL volume is fixed with no adjustment capability, restricting its use to applications requiring exactly 50 µL transfers.