Dual-Chamber Mold Incubator 150 L 0-60°C UV ATOMFAIR®

$4,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

150 L dual-chamber mold incubator with 0-60°C control, 0.1°C resolution, ±0.5°C fluctuation, UV sterilization, and 3 shelves per chamber. Order now.

SKU: AF-LE-E-MINC-0150-2M15
Category:
Tags: , ,
Brands:

150L Multi-Chamber Dual-Chamber Mold Incubator, 0-60℃ Temperature Control Range
Research-grade laboratory product
Product Overview

150L Multi-Chamber Dual-Chamber Mold Incubator, 0-60℃ Temperature Control Range is designed for mold and fungal culture, microorganism observation, constant-temperature storage, and routine environmental incubation. With a nominal capacity of 150 L and a temperature range of 0-60℃, it supports controlled handling of cultures, fungal samples, microorganisms, preserved materials, and other laboratory test loads.

The cabinet layout is defined by the chamber size is 660×520×450mm, overall dimensions are 845×745×1975mm, the standard shelf setup is 3 shelves per chamber, input power is 2200 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±0.5°C fluctuation control, ±1°C at 25°C temperature uniformity, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-MI150-2BOX: Liquid-crystal display controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Dual-Chamber Mold Incubator
Nominal Capacity 150 L
Atomfair Models AF-MI150-2BOX
Temperature Range 0-60℃
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±0.5°C
Temperature Uniformity ±1°C at 25°C
Input Power 2200 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 30°C
Chamber Size 660×520×450mm
Overall Dimensions 845×745×1975mm
Shelves 3 shelves per chamber
Timer 0 to 5999 min
UV Sterilization Standard
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading.
Controller Configuration AF-MI150-2BOX: Liquid-crystal display controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations; UV sterilization system, standard or optional depending on the selected mold configuration; UV sterilization status for this configuration: Standard. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±0.5°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Temperature uniformity of ±1°C at 25°C helps reduce position-related differences inside the chamber, which is valuable when multiple vessels are loaded at once.
  • The multi-chamber structure improves batch separation, making it easier to run parallel work with less door-opening interference between different sample sets.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for laboratories that need mold or microbial incubation in separated batches, allowing different sample groups to be organized in parallel while reducing unnecessary disturbance between chambers.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This incubator requires an ambient temperature between +5 and 30°C for proper operation. Electrical supply must be AC220V 50Hz with a dedicated circuit capable of 2200W.

  • Ambient Temperature Limit: Operate the incubator within an ambient temperature range of +5 to 30°C to maintain specified temperature performance.
  • Electrical Supply Requirement: Connect the incubator to a grounded AC220V 50Hz power source with a minimum 2200W capacity.

How does the temperature uniformity of ±1°C at 25°C in the dual-chamber mold incubator affect parallel culture experiments?

The ±1°C uniformity at 25°C ensures minimal position-dependent temperature variation across each chamber, reducing variability when multiple vessels are loaded simultaneously. This is supported by the 0.1°C resolution and ±0.5°C fluctuation control, enabling consistent conditions for mold and fungal cultures across both chambers.

Can the AF-MI150-2BOX dual-chamber incubator be integrated with external data logging systems via RS485 or USB?

Yes, optional RS485 communication interface and USB data transfer are available for selected configurations, allowing real-time temperature recording and export. The embedded printer option also provides hard-copy records. These accessories must be specified at order; contact inquiry@atomfair.com for availability.

What cleaning and sterilization procedures are recommended for the mirror stainless-steel inner chamber with rounded corners?

The mirror stainless-steel inner chamber with rounded-corner transitions facilitates easier cleaning and reduces contamination risk. UV sterilization is standard for this configuration, providing in-chamber decontamination between runs. The removable/adjustable shelf supports allow thorough access for cleaning and maintenance.

The 150L dual-chamber mold incubator (model AF-MI150-2BOX) provides independent incubation zones with a 0-60°C range, 0.1°C resolution, and ±0.5°C fluctuation, enabling parallel batch processing for mold and fungal cultures while minimizing cross-chamber disturbance.

Positive

  • Dual-chamber batch separation: The multi-chamber layout allows parallel incubation of different sample groups with reduced door-opening interference, improving workflow efficiency for mold and microbial cultures.
  • Fine temperature control stability: With 0.1°C resolution, ±0.5°C fluctuation, and ±1°C uniformity at 25°C, the system supports reproducible conditions for routine cultivation and preservation protocols.

Trade-offs

  • High power and ambient limits: The 2200 W input power and +5 to 30°C ambient temperature requirement constrain placement to climate-controlled labs with adequate electrical capacity.
  • Lead time for optional accessories: Add-ons such as RS485, USB data transfer, or programmable controllers may be non-stock and require lead time, necessitating early planning for data logging or alarm integration.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).