875L Mid-Humidity (20%-60% RH) Dry CabinetsDry storage cabinet, mid-humidity control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The Atomfair AF-DC875A dry cabinet requires specific handling and installation procedures to ensure proper humidity control. Operational constraints include maintaining door closure, stable power supply, and level placement.
- Transport Requirement: Transport the cabinet upright with reinforced outer protection and use suitable lifting equipment.
- Installation Requirement: Install the cabinet on a level surface and confirm door sealing and shelf loading before use.
- Power Requirement: Connect the cabinet to a stable electrical power source for continuous dehumidification.
- Door Sealing Requirement: Keep the cabinet door closed during normal operation to maintain humidity set point.
- Humidity Range Constraint: The cabinet operates within 20-60% RH and cannot achieve ultra-low humidity without optional nitrogen purge.
Follow these steps to properly install and begin operating the AF-DC875A dry cabinet. Ensure all handling and power requirements are met before storing moisture-sensitive materials.
Required Equipment: Lifting equipment, Leveling tool
- Transport to location
Transport the cabinet upright to the installation location using suitable lifting equipment. - Level the cabinet
Place the cabinet on a level surface and adjust the leveling feet to ensure stability. - Connect power
Connect the cabinet to a stable electrical power source and verify the LCD display illuminates. - Set humidity set point
Set the desired humidity set point using the microcomputer control panel. - Load materials
Load materials onto the adjustable shelves, ensuring even weight distribution and airflow. - Close and seal door
Close the cabinet door securely and verify the magnetic gasket seals properly. - Monitor humidity
Monitor the LCD display to confirm humidity reaches the set point before storing sensitive materials.
What are the limitations of using a mid-humidity (20%-60% RH) cabinet for storing moisture-sensitive components compared to lower humidity grades?
The AF-DC875A provides balanced dry storage without an ultra-dry environment (20%-60% RH), suitable for preventing moisture absorption and oxidation in many materials. However for ultra-low (<10% RH) or extreme-low (<3% RH) humidity applications the manufacturer advises validating the storage process before formal production use and considering optional nitrogen purge or over-humidity alarm systems when process risk is high.
Can this dry cabinet be integrated into an existing laboratory monitoring system for real-time humidity tracking?
Yes via the optional RS485 PC logging interface which enables real-time data logging remote monitoring and traceability of cabinet humidity and temperature status. The built-in Honeywell temperature/humidity sensor provides ±3% RH accuracy with low annual drift supporting reliable long-term measurement.
What are the critical installation requirements for ensuring proper operation of the Atomfair AF-DC875A dry cabinet?
The cabinet must be transported upright with reinforced outer protection moved with suitable lifting equipment then installed on a level surface confirming door sealing shelf loading and stable power before storing sensitive materials. During normal use keep the door closed to minimize ambient exposure.
The Atomfair AF-DC875A 875L dry cabinet provides mid-humidity control (20%-60% RH) with a Honeywell sensor and automatic electronic dehumidification, making it suitable for general moisture-sensitive storage in labs and workshops, but it is not designed for ultra-low humidity applications and requires careful handling due to its size.
Positive
- Honeywell sensor with ±3% RH accuracy: The integrated Honeywell temperature and humidity sensor provides ±3% RH accuracy with 0.3% annual drift, enabling reliable long-term measurement for consistent humidity control.
- No disposable desiccant consumables: The automatic electronic dehumidification module eliminates the need for disposable desiccants, reducing ongoing maintenance and consumable costs while supporting continuous operation.
Trade-offs
- Limited to mid-humidity range: This model controls humidity only within 20%-60% RH, making it unsuitable for materials requiring ultra-low (<20% RH) or extreme-low (<10% RH) environments without upgrading to a different humidity grade model.
- Requires careful handling and leveling: The 875L cabinet must be transported upright with reinforced protection, and after installation, level placement, door sealing, and stable power must be confirmed before use, adding setup complexity.