|
Balanced-Control Constant Temperature and Humidity Chamber, 50 L,45-95%RH
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a working environment of +5 to 30 °C and a dedicated AC 220 V, 50 Hz power supply rated at 1700 W. The independent over-temperature alarm activates during abnormal conditions to protect samples and notify operators.
- Installation Space Constraint: Confirm installation space against the external dimensions of 720 x 620 x 725 mm to ensure adequate clearance for air inlets, test ports, and maintenance access.
- Power Supply Requirement: Prepare a dedicated AC 220 V, 50 Hz power supply rated at 1700 W to support stable chamber operation.
- Over-Temperature Alarm Constraint: The independent over-temperature alarm activates during abnormal conditions to protect samples and notify operators.
Position the chamber in a clean, level area with ambient temperature between +5 and 30 °C and connect to a dedicated AC 220 V, 50 Hz power supply. Verify the humidity sensor and balancing-control package before initiating the first test cycle.
Required Equipment: Reinforced packaging and suitable lifting equipment, AC 220 V, 50 Hz power supply
- Unpack and Position
Keep the packed chamber upright and use suitable lifting equipment during unloading and positioning to prevent damage. - Verify Installation Space
Confirm the installation area accommodates the external dimensions of 720 x 620 x 725 mm with accessible air inlets, test ports, and controller surfaces. - Connect Power Supply
Connect the chamber to a dedicated AC 220 V, 50 Hz power supply rated at 1700 W. - Set Temperature and Humidity Parameters
Set the desired temperature and humidity parameters using the microcomputer balancing temperature and humidity controller. - Verify Over-Temperature Alarm
Verify the independent over-temperature alarm is functional before initiating unattended operation.
How does the balancing temperature-humidity controller in the LHS-50CL maintain stability during fluctuating ambient conditions?
The LHS-50CL uses a microcomputer balancing temperature and humidity controller paired with an imported humidity sensor and balancing-control package. This system maintains temperature fluctuation and uniformity within ±1°C and humidity deviation within ±3%RH across the specified range of -10 to 85°C and 45% to 95%RH, supporting stable day-to-day laboratory operation.
What are the installation space and power requirements for the LHS-50CL constant temperature and humidity chamber?
The LHS-50CL has external dimensions of 720 x 620 x 725 mm and requires a power supply of AC 220 V, 50 Hz at 1700 W. The working environment must be maintained at +5 to 30°C. Installation planning should ensure access for air inlets, test ports, shelving, drain areas, doors, and controller surfaces for cleaning and maintenance.
Does the LHS-50CL include independent over-temperature protection for unattended operation?
Yes, the LHS-50CL features an independent over-temperature alarm protection system that improves safety during unattended conditioned testing. It helps protect samples by notifying operators when abnormal conditions occur, reducing operational risk in long-duration laboratory use.
The LHS-50CL balanced-control constant temperature and humidity chamber provides a 50 L volume with a -10 to 85 °C range and 45–95% RH humidity control, suitable for material, packaging, and biological tests requiring repeatable environmental conditioning. Its mirror-finish stainless-steel interior and independent over-temperature alarm support safe, clean operation, while the side test port enables external sensor verification.
Positive
- Balancing humidity and temperature control: The microcomputer balancing controller maintains stable humidified conditions (45–95% RH) within ±3% RH deviation, supporting incubation, cultivation, and conditioning tests with minimal drift.
- Mirror-finish stainless-steel chamber interior: The corrosion-resistant, smooth interior with removable shelving simplifies cleaning and reduces cross-contamination between test runs, a practical advantage for repeated use in laboratory environments.
Trade-offs
- Narrow humidity range above ambient: The humidity function is limited to 45–95% RH, which cannot support low-humidity tests below 45% RH or high-humidity saturation beyond 95% RH, restricting application scope to moderate conditioning studies.
- Ambient temperature installation requirement: The chamber requires a working environment of +5 to 30 °C, meaning it cannot be placed in unconditioned spaces or near heat sources without affecting setpoint stability and compressor operation.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).






