Balanced-Control Constant Temperature and Humidity Chamber, 100 L,7050W
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This chamber requires a dedicated AC 380 V 50 Hz power supply and an installation space of 700 x 1040 x 1750 mm. The working environment must be maintained between 5 and 30°C, and the independent over-temperature alarm must remain operational for safe unattended use.
- Power Supply: Ensure the electrical infrastructure provides AC 380 V, 50 Hz, 7050 W to avoid overload or damage.
- Installation Space: Plan a laboratory footprint of 700 x 1040 x 1750 mm and allow access for maintenance and cleaning.
- Working Environment: Operate the chamber within an ambient temperature range of +5 to 30°C to maintain performance and safety.
- Over-Temperature Alarm: Do not bypass or disable the independent over-temperature alarm during unattended operation.
- Special-Order Configuration: Confirm the exact controller type, humidity function, and accessories before ordering to avoid shipment delays.
Confirm the installation space and prepare the specified power supply before unpacking. Use suitable lifting equipment to keep the chamber upright during positioning, and ensure all access points remain clear for maintenance.
Required Equipment: Suitable lifting equipment
- Confirm Installation Requirements
Confirm the installation space against 700 x 1040 x 1750 mm and prepare the AC 380 V 50 Hz power supply. - Unpack and Unload
Unload the chamber using suitable lifting equipment while keeping the packed unit upright. - Position and Access
Position the chamber and ensure air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible.
What electrical and physical infrastructure is required to install and operate the LHS-100CB constant temperature and humidity chamber?
The chamber requires a dedicated AC 380 V, 50 Hz power supply rated at 7050 W. Installation space must accommodate external dimensions of 700 x 1040 x 1750 mm, with ambient operating conditions of +5 to 30 °C. The unit is shipped upright in reinforced packaging; suitable lifting equipment is needed for unloading and positioning.
What data communication and logging interfaces are available for integrating the LHS-100CB chamber into a laboratory monitoring system?
The chamber supports optional RS485 communication interface and software for remote data logging and monitoring. Additional options include an LCD program controller for programmable setpoint editing, a wireless alarm system for remote notifications, and an embedded printer for on-site data output. These must be selected as configuration options prior to ordering.
Why does the LHS-100CB model require special order confirmation, and what must be verified before purchase?
The LHS-100CB is a special-order build configuration; the order must be reconfirmed before shipment scheduling. Buyers must verify the exact controller type, lighting form, humidity function, and all accessory options (RS485, LCD controller, wireless alarm, printer) to ensure the final unit matches the intended application needs.
The LHS-100CB balanced-control constant temperature and humidity chamber provides 100 L capacity with -40 to 85°C temperature range and 45-95% RH humidity control, featuring mirror-finish stainless steel interior and independent over-temperature alarm for safe, stable environmental testing in laboratory applications.
Positive
- Balancing Temperature-Humidity Control: Maintains a stable operating band for humidity-sensitive incubation, cultivation, conditioning, and stability studies, supporting repeatable environmental test conditions.
- Mirror-Finish Stainless Steel Interior: Facilitates cleaning and chamber preparation between test runs, supporting repeated cleaning, chamber hygiene, and long-duration laboratory use.
Trade-offs
- High Power and Three-Phase Supply Required: Requires 7050 W power input and AC 380 V, 50 Hz supply, necessitating dedicated electrical infrastructure and installation planning.
- Special-Order Build Lead Time: CB configuration is commonly supplied as a special-order build, requiring reconfirmation before shipment scheduling, which may extend delivery time.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).