190 L Gas-Jacket CO2 Incubator 90 °C Sterilization ATOMFAIR®

$8,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

190 L gas-jacket CO2 incubator with 90 °C sterilization, 750 W power, 0–20% CO2 control, ±0.1% accuracy and touchscreen monitoring. Order now.

SKU: AF-LE-E-RHRW-0190-19RH
Category:
Brands:

190 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
Product Overview

190 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series is designed for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows. Touchscreen trend charts, CO2 control with optional O2 monitoring, and sterilization variants for advanced culture workflows. The configuration provides RT + 3 to 55 °C, 750 W rated power, a working chamber of 520 × 530 × 690 mm (W × D × H), and external dimensions of 708 × 710 × 1030 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large touchscreen interface with curve display and record review. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching.

This equipment is suited to laboratories that need advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2H-190G
Product Family CO2 Incubator, High-End Touchscreen Series
Configuration 190 L Gas-Jacket 90 °C Sterilization
Rated Operating Power 750 W
Working Chamber Size 520 × 530 × 690 mm (W × D × H)
Overall Dimensions 708 × 710 × 1030 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
O2 Option Optional zirconia O2 control from 1% to 90%
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Controller Large touchscreen interface with curve display and record review
Optional Accessories and Functions Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching
Performance Features
  • The touchscreen controller supports trend curves, alarm review, and 72-hour running record lookup according to the product design. This makes real-time parameter review and routine operation easier in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Infrared CO2 sensing and optional O2 control support advanced gas-environment culture workflows. This allows the configuration to match documentation, communication and monitoring needs in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • RHP models use 90 °C high-temperature and high-humidity sterilization, while selected RWP(90) models add UV and 90 °C sterilization support. This supports chamber hygiene and contamination-control routines for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • An environmental temperature monitoring system and heated outer door support stable chamber control and reduced condensation. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional wireless alarm, account permissions, external temperature and CO2 monitoring, and automatic cylinder switching are listed. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Alarm coverage includes power failure, CO2 deviation, door opening, and multiple temperature sensor conditions. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
APPLICATION SCOPE: Suitable for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 708 × 710 × 1030 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a dedicated AC 220 V, 50 Hz power supply and must be operated within an ambient temperature range of 5 to 30 °C. The packed unit must be kept upright during transport, and the chamber must remain accessible for cleaning and inspection.

  • Power Supply Requirement: The incubator requires a dedicated AC 220 V, 50 Hz power supply with adequate capacity for the 750 W rated power.
  • Ambient Temperature Range: The incubator must be operated within an ambient temperature range of +5 to +30 °C to maintain specified performance.
  • Transport Orientation: The packed incubator must be kept upright during transport and handled with suitable lifting equipment to avoid internal damage.
  • Sterilization Cycle Safety: The 90 °C sterilization cycle must be performed with the chamber empty and all internal components rated for high-temperature exposure.
  • Chamber Accessibility: The chamber, sensors, shelves, filters, doors, and control interfaces must remain accessible for routine cleaning and inspection.

This procedure describes the initial installation and safety verification of the CO2 incubator. Follow these steps to ensure proper placement, power connection, and operational readiness.

Required Equipment: Lifting equipment

  1. Transport the incubator
    Transport the packed incubator upright using suitable lifting equipment to the installation location.
  2. Confirm space and power
    Confirm the available space matches the external dimensions (708 x 710 x 1030 mm) and provide a dedicated AC 220 V, 50 Hz power supply.
  3. Ensure accessibility
    Ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces are accessible for cleaning, inspection, and operation.

What is the CO2 recovery time of the 190 L Gas-Jacket CO2 incubator after a door opening?

The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications.

Can the Atomfair AF-CO2H-190G incubator be used for hypoxic or hyperoxic cell culture experiments?

Yes, the incubator supports optional zirconia O2 control from 1% to 90%, allowing both hypoxic and hyperoxic culture conditions. This option must be specified at purchase as it is not included in the base configuration.

What are the space and power requirements for installing the 190 L CO2 incubator?

The incubator requires external dimensions of 708 × 710 × 1030 mm (W × D × H) and a power supply of AC 220 V, 50 Hz at 750 W. The working ambient temperature must be between +5 and +30 °C. Ensure the installation space allows access to the chamber, sensors, and controls as per the handling instructions.

The 190 L Gas-Jacket CO2 incubator (model AF-CO2H-190G) provides ±0.1°C temperature stability, ±0.1% CO2 accuracy with infrared sensor, and 90°C high-temperature sterilization, supporting advanced cell culture and optional O2-controlled cultivation with traceable monitoring via touchscreen interface.

Positive

  • Infrared CO2 Sensing with Fast Recovery: CO2 control accuracy of ±0.1% and recovery to 5% within 3 minutes after a 30-second door opening ensure stable gas conditions during routine access.
  • 90°C Sterilization for Contamination Control: High-temperature and high-humidity sterilization at 90°C supports chamber hygiene and reduces contamination risk in long-term culture workflows.

Trade-offs

  • Ambient Temperature and Power Supply Requirements: The unit requires a working ambient temperature of +5 to +30°C and a dedicated AC 220 V, 50 Hz power supply, limiting placement and infrastructure compatibility.
  • Optional Feature Dependence for Advanced Workflows: O2 control, humidity display, and wireless alarm are optional accessories; the base configuration does not include these functions, requiring separate selection and procurement.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).