CO2 Incubator 155 L 90°C Touchscreen Sterilization ATOMFAIR®

$8,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

155 L CO2 incubator with 90 °C sterilization, 700 W power, 0-20% CO2 control and ±0.1 °C stability for advanced cell culture workflows. Order now.

SKU: AF-LE-E-RHRW-0155-15RH
Category:
Brands:

155 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
Product Overview

155 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series is designed for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows. Touchscreen trend charts, CO2 control with optional O2 monitoring, and sterilization variants for advanced culture workflows. The configuration provides RT + 3 to 55 °C, 700 W rated power, a working chamber of 480 × 530 × 610 mm (W × D × H), and external dimensions of 670 × 770 × 880 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large touchscreen interface with curve display and record review. laboratory chamber construction The model includes 2 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching.

This equipment is suited to laboratories that need advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2H-155G
Product Family CO2 Incubator, High-End Touchscreen Series
Configuration 155 L Gas-Jacket 90 °C Sterilization
Rated Operating Power 700 W
Working Chamber Size 480 × 530 × 610 mm (W × D × H)
Overall Dimensions 670 × 770 × 880 mm (W × D × H)
Shelf Configuration 2 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
O2 Option Optional zirconia O2 control from 1% to 90%
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Controller Large touchscreen interface with curve display and record review
Optional Accessories and Functions Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching
Performance Features
  • The touchscreen controller supports trend curves, alarm review, and 72-hour running record lookup according to the product design. This makes real-time parameter review and routine operation easier in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Infrared CO2 sensing and optional O2 control support advanced gas-environment culture workflows. This allows the configuration to match documentation, communication and monitoring needs in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • RHP models use 90 °C high-temperature and high-humidity sterilization, while selected RWP(90) models add UV and 90 °C sterilization support. This supports chamber hygiene and contamination-control routines for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • An environmental temperature monitoring system and heated outer door support stable chamber control and reduced condensation. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional wireless alarm, account permissions, external temperature and CO2 monitoring, and automatic cylinder switching are listed. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Alarm coverage includes power failure, CO2 deviation, door opening, and multiple temperature sensor conditions. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
APPLICATION SCOPE: Suitable for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 670 × 770 × 880 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be installed in a location with ambient temperature 5–30 °C, adequate ventilation, and a dedicated AC 220 V, 50 Hz grounded power supply rated for 700 W. The chamber must remain upright during transport and storage, and all internal surfaces, sensors, and ports must be kept accessible for routine cleaning and inspection.

  • Space requirement: Before installation, verify the available floor space accommodates the 670 × 770 × 880 mm external dimensions and allow clearance for door swing and maintenance access.
  • Power supply verification: Confirm the power supply matches the required AC 220 V, 50 Hz specification and that the circuit is rated for the 700 W load.
  • Transport orientation: During transport, keep the packaged incubator upright and use lifting equipment suitable for the weight to avoid damage.
  • Accessibility for operation: After unpacking, ensure the chamber door, sensors, shelves, filters, and test ports are unobstructed and accessible for cleaning and operation.
  • Gas cylinder connection: If optional gas cylinders are used, connect them according to the manufacturer's instructions and secure them to prevent tipping.

How does the CO2 recovery time of less than 3 minutes affect cell culture protocols after frequent door openings?

The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, minimizing environmental disruption during routine sample handling. This rapid recovery, enabled by the gas-jacket design and infrared CO2 sensor, helps maintain stable culture conditions for sensitive cell lines.

Can this incubator support hypoxic or low-oxygen cell culture experiments?

Yes, the incubator offers an optional zirconia O2 control system that can regulate oxygen concentration from 1% to 90%, enabling hypoxic or hyperoxic experiments. The touchscreen interface and built-in monitoring allow real-time tracking and recording of O2 levels alongside CO2 and temperature.

What are the installation requirements for the 155L gas-jacket CO2 incubator regarding power supply and ambient conditions?

The incubator requires a 220 V, 50 Hz power supply with 700 W rated power. The ambient temperature must be between +5 and +30 °C, and the external dimensions are 670 × 770 × 880 mm (W × D × H), so adequate space for ventilation and access is needed. The heated outer door and environmental temperature monitoring system help maintain stable internal conditions.

The 155 L Gas-Jacket CO2 incubator with 90°C sterilization provides ±0.1% CO2 control accuracy and <3-minute recovery to 5% CO2 after door opening, supporting reproducible cell culture. The touchscreen interface with trend curves and 72-hour record lookup enhances traceability, though the unit requires AC 220V/50Hz power and a controlled ambient temperature of +5 to +30°C.

Positive

  • Fast CO2 recovery after door opening: CO2 concentration recovers to 5% within 3 minutes after a 30-second door opening, minimizing disruption to gas-sensitive cultures.
  • Touchscreen with trend and record review: Large touchscreen interface displays real-time curves and stores 72-hour running records, enabling direct traceability and parameter review without external logging.

Trade-offs

  • Specific power supply requirement: Operates on AC 220 V, 50 Hz only, which may require a voltage converter or dedicated circuit in regions with different mains standards.
  • Narrow ambient temperature range: Working ambient temperature must be maintained between +5 and +30 °C, necessitating climate-controlled laboratory conditions to avoid performance degradation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).