120 L Biological Safety Low-Temperature Incubator with HEPA Filtration
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a controlled environment with ambient temperature at least 20 °C below the set chamber temperature to achieve the minimum 4 °C operating point. HEPA filtration and UV sterilization are integral to maintaining chamber cleanliness for contamination-sensitive workflows.
- Power Supply Requirement: The unit must be connected to an AC 220 V, 50 Hz power supply with sufficient capacity for the 1500 W rated operating power.
- Installation Space Requirement: Installation requires clear floor space accommodating the 693 × 875 × 753 mm external dimensions with accessible clearance for chamber doors, test ports, and control interfaces.
- Sterilization Compatibility: Optional 90 °C high-temperature and high-humidity sterilization cycle is compatible only when the corresponding accessory is installed and configured.
- Transport Orientation Constraint: During transport, the packed incubator must remain upright and be handled with suitable lifting equipment to prevent internal damage.
This procedure covers initial installation, power connection, and basic operation of the incubator for low-temperature biological safety cultivation. Follow these steps to ensure proper chamber conditioning and workflow readiness.
Required Equipment: AC 220 V, 50 Hz power supply, 7-inch color touchscreen controller
- Position the Incubator
Place the incubator on a level, stable surface with adequate clearance around the 693 × 875 × 753 mm footprint for door access and ventilation. - Connect Power Supply
Connect the unit to a dedicated AC 220 V, 50 Hz power outlet rated for at least 1500 W to ensure stable operation. - Set Temperature Parameters
Use the touchscreen controller to set the desired temperature within the 4 to 65 °C range, ensuring the ambient temperature is at least 20 °C below the set point. - Activate Sterilization Cycle
If using the optional high-temperature sterilization, initiate the 90 °C high-humidity cycle via the controller before loading samples. - Load Samples onto Shelves
Arrange samples on the 304 stainless-steel shelves, ensuring even spacing for uniform airflow and temperature distribution. - Enable Monitoring Functions
Configure USB data export or optional App monitoring to log chamber conditions for documentation and compliance.
What is the minimum chamber temperature achievable in a 25°C ambient room with this 120 L biological safety low-temperature incubator?
The incubator can achieve a minimum chamber temperature of 20°C below ambient, with a control range of 4 to 65°C. In a 25°C ambient room, the minimum achievable chamber temperature is 5°C, as specified by the temperature control range and the 20°C-below-ambient constraint.
How does six-side heating contribute to contamination control in this incubator?
Six-side heating heats all interior surfaces, reducing temperature gradients that cause condensation. This helps maintain a cleaner cultivation environment by minimizing moisture buildup, which is critical for contamination-sensitive workflows such as microbiology and clean chamber incubation.
What power supply specifications are required for installation of the AF-BSLI-120 incubator?
The incubator requires AC 220 V, 50 Hz power supply with a rated operating power of 1500 W. The source does not list support for 110 V or 60 Hz, so the power supply must be confirmed before installation to ensure compatibility.
This 120 L biological safety low-temperature incubator provides HEPA filtration, six-side heating, and a 304 stainless steel chamber for contamination-sensitive cultivation at 4–65 °C with ±0.1 °C stability, but requires a 220 V/50 Hz supply and its minimum temperature depends on ambient conditions (20 °C below ambient).
Positive
- HEPA filtration for clean chamber air: Standard HEPA filter removes bacteria and dust from circulating air, supporting contamination-sensitive low-temperature biological safety cultivation and microbiology work.
- Six-side heating reduces condensation: Heating on all six sides helps minimize internal condensation, maintaining a cleaner cultivation environment and supporting repeated cleaning and maintenance.
Trade-offs
- Temperature range depends on ambient: Minimum chamber temperature is 20 °C below ambient, so achievable low temperatures are constrained by the laboratory environment; for example, at 25 °C ambient the minimum is 5 °C, not 4 °C.
- Requires specific power supply: The incubator is specified for AC 220 V, 50 Hz only, which may require voltage conversion or dedicated circuit installation in regions with different mains power.