Biological Safety Incubator 190 L AF-BSIN-190 ATOMFAIR®

$4,200.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

190 L biological safety incubator with HEPA filtration, UV sterilization, 750 W power, RT + 5 to 50 °C control, and 520 × 530 × 690 mm chamber. Order now.

SKU: AF-LE-E-BSIN-0190-S190
Category:
Brands:

190 L Biological Safety Incubator with HEPA Filtration
Research-grade laboratory product
Product Overview

190 L Biological Safety Incubator with HEPA Filtration is designed for biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation. Gas-jacket heating, HEPA filtration, UV sterilization, and touchscreen monitoring for biological safety incubation. The configuration provides RT + 5 to 50 °C, 750 W rated power, a working chamber of 520 × 530 × 690 mm (W × D × H), and external dimensions of 708 × 710 × 1030 mm (W × D × H).

The control and chamber design support practical laboratory operation: Touchscreen controller with password lock. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system.

This equipment is suited to laboratories that need biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BSIN-190
Product Family Biological Safety Incubator
Configuration 190 L
Rated Operating Power 750 W
Working Chamber Size 520 × 530 × 690 mm (W × D × H)
Overall Dimensions 708 × 710 × 1030 mm (W × D × H)
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 5 to 50 °C
Working Ambient Temperature +5 to +30 °C
Temperature Stability ±0.1 °C at 37 °C
Temperature Uniformity ±0.5 °C at 37 °C
Sterilization Method UV sterilization
Power Supply AC 220 V, 50 Hz
Controller Touchscreen controller with password lock
Chamber Protection HEPA filter and test port access
Optional Accessories and Functions 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system
Performance Features
  • This product family combines incubation control and biological safety protection with standard HEPA filtration. This helps maintain cleaner chamber air for contamination-sensitive biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • A touchscreen controller supports direct monitoring and parameter setting, with password locking to reduce unintended changes. This makes real-time parameter review and routine operation easier in biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • Six-side heating reduces condensation inside the chamber and supports stable culture conditions. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • The chamber and shelves use stainless-steel construction for cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • USB export, electronic signature support, and optional App monitoring support traceable operation. This allows the configuration to match documentation, communication and monitoring needs in biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • Optional 90 °C high-temperature and high-humidity sterilization is available for inner chamber decontamination. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
APPLICATION SCOPE: Suitable for biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 708 × 710 × 1030 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires an ambient temperature range of +5 to +30 °C and a stable AC 220 V, 50 Hz power supply. HEPA filtration and UV sterilization are integral to maintaining contamination-sensitive culture conditions.

  • Temperature Stability Constraint: Temperature stability is ±0.1 °C and uniformity is ±0.5 °C at 37 °C, requiring the unit to be placed away from drafts or heat sources that could disrupt control.
  • Sterilization Method Constraint: UV sterilization is standard, with an optional 90 °C high-temperature and high-humidity sterilization system available for deeper decontamination.
  • Chamber Access Constraint: The working chamber dimensions of 520 × 530 × 690 mm require that all internal components, shelves, and filters remain accessible for cleaning and inspection.

Before use, confirm the installation space meets the 708 × 710 × 1030 mm external dimensions and that the power supply matches AC 220 V, 50 Hz. The following steps describe the standard startup and sterilization workflow.

Required Equipment: Touchscreen controller with password lock, UV sterilization system

  1. Verify Installation Space and Power
    Confirm the incubator is placed on a level surface with at least 10 cm clearance on all sides and connected to a dedicated AC 220 V, 50 Hz outlet.
  2. Power On and Unlock Controller
    Turn on the main power switch and enter the password on the touchscreen controller to unlock the interface.
  3. Set Temperature Parameters
    Set the desired incubation temperature within the range of RT + 5 to 50 °C using the touchscreen controller.
  4. Activate UV Sterilization Cycle
    Initiate the UV sterilization cycle for at least 30 minutes before loading samples to decontaminate the chamber interior.
  5. Load Samples and Close Door
    Place culture vessels on the stainless-steel shelves, ensuring they do not block the HEPA filter intake or exhaust ports, then close the door securely.
  6. Monitor Temperature and Alarms
    Verify the temperature stability reading on the touchscreen and confirm no alarm indicators are active before leaving the unit unattended.

How does the gas-jacket heating system affect temperature uniformity and stability in the 190 L biological safety incubator?

The gas-jacket microcomputer PID control provides temperature stability of ±0.1 °C and uniformity of ±0.5 °C at 37 °C. Six-side heating reduces condensation and supports stable culture conditions across the 520 × 530 × 690 mm working chamber.

Can the AF-BSIN-190 incubator be integrated with external monitoring or data logging systems?

Yes, the incubator supports optional RS485 interface and communication software, USB data storage, and an embedded printer for data export. The touchscreen controller includes password lock and electronic signature function for traceable operation. An optional smart App control system is also available.

What sterilization options are available for decontaminating the chamber between experiments?

The standard unit includes UV sterilization. An optional 90 °C high-temperature and high-humidity sterilization system is available for inner chamber decontamination. The chamber and shelves are stainless steel for cleaning, and HEPA filtration helps maintain cleaner chamber air during operation.

The 190 L Biological Safety Incubator with HEPA Filtration (AF-LE-E-BSIN-0190-S190) combines gas-jacket heating, six-side temperature control, and HEPA filtration to maintain stable, contamination-reduced conditions for temperature-sensitive biological culture work. Its moderate temperature range (RT+5 to 50°C) and specific ambient and power requirements must be factored into lab infrastructure planning.

Positive

  • HEPA filtration for contamination control: Integrated HEPA filter helps maintain cleaner chamber air, reducing particulate contamination risk during sensitive biological incubation and culture work.
  • Six-side gas-jacket heating uniformity: Gas-jacket heating with six-side distribution minimizes condensation and supports temperature stability of ±0.1°C and uniformity of ±0.5°C at 37°C, critical for reproducible culture conditions.

Trade-offs

  • Limited temperature range: Controlled range is only RT+5 to 50°C, which excludes high-temperature decontamination protocols unless the optional 90°C sterilization system is fitted.
  • Strict ambient and power requirements: Requires a working ambient temperature of +5 to +30°C and a dedicated AC 220V, 50Hz supply; deviations may impair performance or require additional infrastructure.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).