360L General Biochemical Incubator with 0-70°C Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
When the set temperature is below 10°C, ambient temperature must be below 26°C to maintain stable operation. The unit requires a clean, well-ventilated laboratory environment with AC 220 V, 50 Hz power supply and adequate floor space for the 835 x 755 x 1695 mm external dimensions.
- Ambient Temperature Constraint: Ambient temperature must be maintained below 26°C when the incubator set point is below 10°C.
- Power Supply Requirement: The incubator requires a dedicated AC 220 V, 50 Hz power supply with sufficient capacity for the 900 W rated power.
- Installation Space Constraint: The installation location must accommodate the 835 x 755 x 1695 mm external dimensions and allow adequate airflow around the cabinet.
Set the desired temperature using the microcomputer control and LCD display, then load samples onto the removable stainless-steel shelves. Monitor chamber conditions through the inner observation window to minimize door openings and maintain temperature stability.
Required Equipment: Microcomputer control with LCD display, Removable stainless-steel shelves
- Verify ambient conditions
Confirm that ambient temperature is below 26°C if the set point will be below 10°C. - Set the target temperature
Use the microcomputer control panel to enter the desired temperature within the 0 to 70°C range. - Load samples onto shelves
Arrange culture containers or samples on the removable shelves, ensuring adequate spacing for air circulation. - Close the door securely
Seal the magnetic door fully to maintain chamber tightness and reduce thermal disturbance. - Set the timer if needed
Program the built-in timer for up to 9999 minutes to enable scheduled operation without manual supervision. - Monitor chamber conditions
Observe temperature and timing status on the LCD display and use the inner observation window to check samples without opening the door.
How does the 360L biochemical incubator achieve ±2°C temperature uniformity across the chamber?
The incubator uses a circulation fan and air-duct structure combined with PID temperature control to improve chamber temperature uniformity. The specified uniformity is ±2°C, supported by the microcomputer control and LCD display for monitoring set and current temperatures.
What are the ambient temperature requirements when operating the incubator below 10°C?
When the set temperature is below 10°C, the ambient temperature must be below 26°C to maintain stable operation. This constraint is explicitly stated in the product specifications and is critical for low-temperature applications such as BOD work or sample holding.
What safety and reliability features does the incubator include for unattended operation?
The incubator includes self-diagnosis, over-temperature limit support, and power-failure memory functions to enhance operational reliability. These features help protect samples during continuous or scheduled runs without constant manual supervision.
This 360L biochemical incubator provides a 0-70°C range with ±1°C accuracy and ±2°C uniformity, suitable for BOD, culture, and preservation workflows, but requires ambient temperature below 26°C when set below 10°C, adding facility cooling demands for low-temperature operation.
Positive
- PID control minimizes temperature fluctuations: PID temperature control reduces fluctuation during operation, supporting consistent incubation and culture storage repeatability across the 360L stainless-steel chamber.
- 0-70°C range for flexible workflows: The 0 to 70°C control range enables both low-temperature storage and standard biochemical incubation, providing versatility for bacteria culture, BOD analysis, and plant cultivation in a single cabinet.
Trade-offs
- Ambient constraint below 10°C setpoint: When the set temperature is below 10°C, ambient temperature must be below 26°C, which may require air conditioning in warmer lab environments to maintain stable low-temperature operation.
- Single voltage and frequency configuration: The unit is designed for AC 220 V, 50 Hz power supply, limiting direct deployment in regions with 60 Hz mains or different voltage standards without a transformer or frequency converter.