250L Biochemical Incubator -5-70°C AF-BI250-BPC25F ATOMFAIR®

$4,200.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

250L biochemical incubator with -5 to 70°C control, 0.1°C resolution, ±1.5°C uniformity at 25°C, chamber 520x550x1050mm, 1300 W, AC220V 50Hz. Order now.

250L Professional Biochemical Incubator, -5-70°C
Research-grade laboratory product
Product Overview

250L Professional Biochemical Incubator, -5-70°C

The cabinet layout is defined by the chamber size is 520x550x1050mm, the standard shelf setup is 3 shelves, input power is 1300 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.3°C; low temp ±0.5°C fluctuation control, ±1.5°C at 25°C temperature uniformity, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-BI250-BPC25F: Liquid-crystal display controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Biochemical Incubator
Nominal Capacity 250 L
Atomfair Models AF-BI250-BPC25F
Temperature Range -5-70°C>
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.3°C; low temp ±0.5°C
Temperature Uniformity ±1.5°C at 25°C
Input Power 1300 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 35°C
Chamber Size 520x550x1050mm
Shelves 3 shelves
Timer 0 to 5999 min
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading.
Controller Configuration AF-BI250-BPC25F: Liquid-crystal display controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.3°C; low temp ±0.5°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Temperature uniformity of ±1.5°C at 25°C helps reduce position-related differences inside the chamber, which is valuable when multiple vessels are loaded at once.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for biochemical incubation, microorganism handling, BOD-related holding, sample preservation, constant-temperature storage, and routine laboratory conditioning where reliable temperature control supports consistent test execution.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

The unit requires an ambient temperature range of +5 to 35°C and a stable AC220V 50Hz power supply for proper operation. Temperature uniformity of ±1.5°C at 25°C and fluctuation of high temp ±0.3°C or low temp ±0.5°C must be considered when positioning samples to minimize position-related variability.

  • Power Supply Constraint: The incubator requires a dedicated AC220V 50Hz power supply with sufficient capacity for the 1300 W input power to avoid electrical instability.
  • Ambient Temperature Constraint: The unit must be operated within an ambient temperature range of +5 to 35°C to maintain specified temperature control performance.
  • Temperature Uniformity Consideration: Temperature uniformity of ±1.5°C at 25°C may cause position-dependent differences when multiple vessels are loaded simultaneously.

Position the incubator on a level, stable surface within the specified ambient temperature range and connect to a dedicated AC220V 50Hz power supply. Configure the liquid-crystal display controller to the desired temperature setpoint and timer duration before loading samples.

Required Equipment: Liquid-crystal display controller, Adjustable shelf supports

  1. Position the Incubator
    Place the incubator on a level, stable surface in an area with ambient temperature between +5 and 35°C and access to a dedicated AC220V 50Hz power outlet.
  2. Install Shelves
    Adjust or install the removable stainless-steel shelves at the desired heights using the rounded-corner supports to accommodate your sample containers.
  3. Connect Power Supply
    Plug the unit into a dedicated AC220V 50Hz power outlet rated for at least 1300 W to ensure stable electrical operation.
  4. Set Temperature Parameters
    Use the liquid-crystal display controller to set the target temperature within the -5 to 70°C range and adjust the timer from 0 to 5999 minutes as needed.
  5. Load Samples
    Place sample vessels onto the shelves, ensuring adequate spacing for air circulation to maintain temperature uniformity of ±1.5°C at 25°C.
  6. Start Operation
    Initiate the incubation cycle via the controller and monitor the display for stable temperature readings within the specified fluctuation limits.

How does the temperature fluctuation differ between high and low temperature operation in the Atomfair 250L biochemical incubator?

The incubator specifies high temp fluctuation of ±0.3°C and low temp fluctuation of ±0.5°C, meaning stability is tighter at elevated setpoints compared to sub-ambient operation. Temperature uniformity is specified as ±1.5°C at 25°C, providing a reference for spatial variation at a typical incubation temperature.

What communication and data logging options are available for the AF-BI250-BPC25F incubator?

The incubator supports optional RS485 communication interface and USB data transfer for recording temperature changes. An embedded printer is also optionally available. These accessories may require lead time and should be confirmed before ordering.

Does the Atomfair 250L biochemical incubator include independent over-temperature protection?

Yes, an independent over-temperature alarm system is available as an optional accessory where supported. The chamber also features a mirror stainless-steel inner chamber with rounded-corner transitions for easier cleaning, which is important for maintaining sterile conditions in microbiological applications.

The 250L Biochemical Incubator delivers 0.1°C temperature resolution and ±0.3/0.5°C fluctuation for stable cultivation, but its ±1.5°C uniformity at 25°C and need for optional add-ons for data logging are practical constraints.

Positive

  • Fine temperature resolution and stability: 0.1°C resolution and ±0.3°C (high temp) / ±0.5°C (low temp) fluctuation support precise setpoint maintenance for routine biochemical incubation and preservation.
  • Hygienic chamber design: Mirror stainless-steel inner chamber with rounded-corner transitions and removable shelf supports simplifies cleaning and reduces contamination risk during repeated loading.

Trade-offs

  • Temperature uniformity tolerance: ±1.5°C uniformity at 25°C indicates spatial gradients that require careful sample placement when uniform conditions across multiple vessels are critical.
  • Data logging requires optional accessories: RS485, USB, and printer functions are optional and may involve non-stock lead times, adding cost and planning effort for users needing continuous data recording.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).