CO2 Incubator 80 L IR Control 90 °C 500 W ATOMFAIR®

$6,300.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

80 L research-grade CO2 incubator with infrared sensing, 0-20% CO2 control, ±0.1 °C stability, 90 °C sterilization and 500 W power. Order now.

SKU: AF-LE-E-CRHC-0080-80CR
Category:
Brands:

80 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
Product Overview

80 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control is designed for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows. Infrared CO2 sensing, 90 °C sterilization, high humidity cell culture support, and recovery-focused chamber design. The configuration provides RT + 3 to 55 °C, 500 W rated power, a working chamber of 400 × 450 × 500 mm (W × D × H), and external dimensions of 590 × 687 × 790 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2C-080
Product Family CO2 Incubator, Professional Cell Culture Series
Configuration 80 L
Rated Operating Power 500 W
Working Chamber Size 400 × 450 × 500 mm (W × D × H)
Overall Dimensions 590 × 687 × 790 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Sterilization 90 °C high-temperature and high-humidity sterilization
Optional Accessories and Functions HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable
Performance Features
  • Infrared CO2 sensing supports stable CO2 control and faster recovery in frequent door-opening workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • A 90 °C high-temperature and high-humidity sterilization cycle can treat the chamber and internal components. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Microbial filtration at the CO2 inlet and optional HEPA filtration support cleaner chamber conditions. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Door heating reduces condensation on the inner glass door and supports cleaner cell culture operation. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • An LCD display, stackable cabinet design, and data export options support day-to-day laboratory use. This makes real-time parameter review and routine operation easier in cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Alarms cover over-temperature, CO2 deviation, and prolonged door opening according to the product design. This helps operators identify abnormal conditions during unattended or extended cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 590 × 687 × 790 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate the incubator within the specified ambient temperature range of +5 to +30 °C and ensure the power supply matches AC 220 V, 50 Hz. Keep the chamber and internal components accessible for cleaning and periodically perform the 90 °C sterilization cycle to prevent contamination.

  • Power Supply Requirements: The incubator requires a dedicated AC 220 V, 50 Hz power supply with proper grounding to avoid electrical hazards.
  • Ambient Conditions: Maintain working ambient temperature between +5 and +30 °C to ensure stable temperature control and prevent overheating.
  • Sterilization Protocol: Perform the 90 °C high-temperature and high-humidity sterilization cycle to treat the chamber and internal components before initial use and after contamination events.
  • Transport and Handling: Keep the packed unit upright during transport and use suitable lifting equipment to avoid damage to the internal components.
  • Accessibility for Maintenance: Ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces are accessible for cleaning, inspection, and operation.

Follow these steps to install, sterilize, and set up the incubator for cell culture workflows. Ensure all safety checks are completed before introducing samples.

  1. Confirm Installation Space and Power
    Verify the installation area provides at least 590 × 687 × 790 mm of clear space and a dedicated AC 220 V, 50 Hz power outlet.
  2. Position and Level the Incubator
    Place the incubator on a level, stable surface and ensure the chamber doors open freely without obstruction.
  3. Connect Power and Check Display
    Plug the power cord into the grounded outlet and turn on the main power switch, then confirm the LCD display activates.
  4. Perform Sterilization Cycle
    Initiate the 90 °C high-temperature and high-humidity sterilization cycle to decontaminate the chamber and internal components before first use.
  5. Set Temperature and CO2 Parameters
    Use the control panel to set the desired temperature, typically 37 °C, and CO2 concentration, typically 5%, for cell culture.
  6. Allow Chamber to Stabilize
    Wait for the temperature and CO2 levels to reach the set points, typically within 8 minutes for temperature and 3 minutes for CO2 after a door opening.
  7. Monitor Alarms During Operation
    Regularly check the alarm system for over-temperature, CO2 deviation, or prolonged door opening to ensure safe and stable incubation conditions.

How quickly does the AF-CO2C-080 CO2 incubator recover CO2 and temperature after a 30-second door opening?

The CO2 recovers to 5% in no more than 3 minutes, and the temperature recovers to 37°C in no more than 8 minutes after a 30-second door opening, as specified in the technical specifications. This rapid recovery supports frequent door-opening workflows in cell culture applications.

Can the AF-CO2C-080 be configured for low-oxygen (hypoxic) cell culture?

Yes, O2 control is available as an optional accessory for the AF-CO2C-080. The base model provides infrared CO2 control from 0 to 20%, and the optional O2 control module can be added to support hypoxic or low-oxygen incubation workflows.

What sterilization method does the AF-CO2C-080 use and how does it affect chamber maintenance?

The incubator uses a 90°C high-temperature and high-humidity sterilization cycle to treat the chamber and internal components. This allows repeated cleaning and decontamination without chemical disinfectants, reducing contamination risk and supporting routine laboratory maintenance.

This 80 L CO2 incubator features infrared CO2 sensing for rapid recovery (≤3 minutes to 5% CO2 after door opening) and 90°C high-temperature sterilization for contamination control, with noted constraints of a 220 V/50 Hz power requirement and a +5 to +30°C ambient temperature range.

Positive

  • Fast CO2 recovery after door opening: Infrared CO2 sensing enables recovery to 5% CO2 in no more than 3 minutes following a 30-second door opening, supporting stable conditions in frequent-access workflows.
  • 90°C high-temperature sterilization cycle: A 90°C high-temperature and high-humidity sterilization cycle treats the chamber and internal components, aiding decontamination and maintenance without chemical agents.

Trade-offs

  • Ambient temperature range limitation: The incubator requires a working ambient temperature of +5 to +30°C, restricting placement to climate-controlled laboratory environments.
  • Fixed AC 220 V, 50 Hz power supply: The unit operates on AC 220 V, 50 Hz only, which may require a dedicated circuit or voltage conversion in laboratories with incompatible electrical infrastructure.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).