Water-Jacket Laboratory Incubator 80 L 65 °C ATOMFAIR®

$1,100.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

80 L water-jacket incubator with RT + 5 to 65 °C control, 650 W power, 400 × 400 × 500 mm chamber, 0.1 °C resolution, and ±0.5 °C uniformity. Order now.

SKU: AF-LE-E-WJIN-0080-9080
Category:
Brands:

80 L Standard Controller Water-Jacket Constant Temperature Incubator
Research-grade laboratory product
Product Overview

80 L Standard Controller Water-Jacket Constant Temperature Incubator is designed for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred. Water-jacket heating, stable holdover after power interruption, and glass inner door observation for constant temperature laboratory work. The configuration provides RT + 5 to 65 °C, 650 W rated power, a working chamber of 400 × 400 × 500 mm (W × D × H), and external dimensions of 550 × 550 × 800 mm (W × D × H).

The control and chamber design support practical laboratory operation: Standard controller or programmable LCD controller in N variants. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-WJIN-080A
Product Family Water-Jacket Constant Temperature Incubator
Configuration 80 L Standard Controller
Rated Operating Power 650 W
Working Chamber Size 400 × 400 × 500 mm (W × D × H)
Overall Dimensions 550 × 550 × 800 mm (W × D × H)
Model Configuration Standard controller
Heating Method Water-jacket heating
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.3 °C
Temperature Uniformity ±0.5 °C at 37 °C
Working Ambient Temperature +5 to +35 °C
Timing Range 0 to 5999 min
Power Supply AC 220 V, 50 Hz
Controller Options Standard controller or programmable LCD controller in N variants
Optional Accessories and Functions LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller
Performance Features
  • Water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption according to the product design. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A glass inner door supports observation, and opening the door pauses operation and cuts heating and circulation fan activity. This helps balance temperature uniformity with sample protection during constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Automatic fan speed control adjusts airflow when the chamber reaches the set temperature. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • N variants include multi-step programmable control for more complex incubation processes. This supports controlled, repeatable operation for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Optional UV sterilization, automatic water filling, printer, U-disk export, and communication interface are listed for this family. This supports chamber hygiene and contamination-control routines for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Alarm functions cover high temperature, over-temperature, low water, and extended door opening conditions. This helps operators identify abnormal conditions during unattended or extended constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
APPLICATION SCOPE: Suitable for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 550 × 550 × 800 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This 80 L incubator requires a stable ambient environment of +5 to +35°C and a dedicated AC 220 V, 50 Hz power supply. The water-jacket heating system necessitates monitoring of water level and avoidance of prolonged door openings to maintain temperature uniformity.

  • Ambient Temperature Range: Operate the incubator only within an ambient temperature range of +5 to +35°C to ensure proper temperature control and component longevity.
  • Power Infrastructure: Connect the incubator to a grounded AC 220 V, 50 Hz outlet with sufficient capacity for the 650 W rated power and allow for proper ventilation.
  • Installation Space: Provide a level surface with at least 550 × 550 × 800 mm of clear space to accommodate the external dimensions and allow access to controls, ports, and doors.
  • Water Jacket Level: Maintain the water jacket at the correct level to prevent low-water alarms and ensure thermal stability and holdover performance.
  • Door and Observation: Opening the outer door during operation pauses heating and fan activity; minimize door openings to preserve temperature uniformity and avoid alarm triggers.

How does the water-jacket system maintain temperature stability during a power interruption?

The water-jacket heating design provides thermal holdover, meaning the retained heat in the water jacket helps maintain chamber temperature for a period after power loss. The product description states that water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption according to the product design. This reduces temperature drift during short outages, supporting sample integrity.

Can this incubator be integrated with external monitoring or data logging systems?

Yes, the 80 L Standard Controller Water-Jacket Incubator supports optional RS485 interface and communication software for external monitoring, as well as optional U-disk data storage and printer connectivity. These accessories are listed as optional functions, allowing integration with laboratory data management systems for documentation and remote oversight.

What safety features prevent sample loss during unattended operation?

The incubator includes multiple alarm functions: high temperature alarm, over-temperature alarm, low water level alarm, and extended door opening alarm. An independent over-temperature controller is available as an optional accessory for added protection. The glass inner door allows observation without opening the main door, and opening the door pauses heating and fan activity to protect samples while maintaining stability.

This 80 L water-jacket incubator (AF-WJIN-080A) provides stable thermal holdover after power interruption and a glass inner door that automatically pauses heating and fan operation when opened, ensuring sample protection. Temperature uniformity is ±0.5°C at 37°C with ±0.3°C fluctuation, suitable for routine incubation workflows.

Positive

  • Water-jacket thermal holdover: Water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption, minimizing temperature drift in short outages.
  • Glass inner door with safety pause: The glass inner door allows visual observation of samples; opening the door pauses operation and cuts heating and circulation fan activity, reducing thermal disturbance and protecting samples.

Trade-offs

  • Limited low-temperature range: Temperature control range is RT+5 to 65°C, so the unit cannot operate below 5°C above ambient, precluding low-temperature incubation or cooling applications.
  • Water-jacket maintenance required: The water-jacket design requires regular water level monitoring and filling; a low-water alarm is included, indicating the need for ongoing maintenance to ensure thermal performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).