170 L Water-Jacket UV plus 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This document lists the environmental, safety, and operational constraints for the CO2 incubator. Adherence to these constraints ensures safe and reliable operation.
- Power Supply Requirement: The incubator requires a stable AC 220 V, 50 Hz power supply and must be connected to a suitable outlet as specified in the technical specifications.
- Ambient Temperature Constraint: The operating ambient temperature must be maintained between +5 and +30 °C to ensure proper temperature control.
- Installation Space Requirement: The installation site must accommodate the external dimensions of 684 × 700 × 960 mm (W × D × H) with sufficient clearance for operation and maintenance.
- Transport Orientation: During transport, the packaged unit must remain upright and be handled with suitable lifting equipment to prevent damage.
- Safety Monitoring: The incubator includes alarm systems for power failure, CO2 deviation, door opening, and temperature sensor faults to alert operators to abnormal conditions.
This procedure outlines the initial setup and safe handling of the CO2 incubator. Follow these steps to ensure proper installation and prepare the unit for operation.
Required Equipment: Lifting equipment
- Transport the unit
Transport the packaged unit upright using suitable lifting equipment to the installation site. - Confirm installation conditions
Confirm that the installation space accommodates the external dimensions of 684 × 700 × 960 mm and that the power supply is AC 220 V, 50 Hz. - Verify accessibility
Verify that the chamber, sensors, shelves, filters, doors, test ports, and control interfaces remain accessible for cleaning, inspection, and operation. - Select optional accessories
Select optional accessories, such as zirconia O2 control or humidity display, according to the required workflow.
What is the CO2 recovery time after a door opening for the 170 L water-jacket CO2 incubator?
The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications. This rapid recovery minimizes disruption to cell culture conditions.
Does the Atomfair CO2 incubator support hypoxic or hyperoxic cell culture with O2 control?
Yes, the incubator offers an optional zirconia O2 control system that can regulate oxygen from 1% to 90%, enabling hypoxic or hyperoxic cultivation. This option is part of the High-End Touchscreen Series and supports advanced gas-environment culture workflows.
What are the external dimensions and power supply requirements for installing the 170 L CO2 incubator?
The incubator has external dimensions of 684 × 700 × 960 mm (W × D × H) and requires a power supply of AC 220 V, 50 Hz with a rated power of 700 W. The working ambient temperature should be between +5 and +30 °C. Ensure adequate space for ventilation and access.
This 170 L water-jacket CO2 incubator with UV and 90°C sterilization provides fast CO2 recovery (≤3 min to 5% after 30 s door open) and stable temperature uniformity (±0.3°C at 37°C), suitable for advanced cell culture workflows, but requires a 220 V/50 Hz power supply and ambient temperature control between +5 and +30°C.
Positive
- Fast CO2 recovery after door opening: CO2 concentration recovers to 5% within 3 minutes after a 30-second door opening, minimizing disruption to cell culture conditions.
- Dual UV and 90°C sterilization: Combined UV irradiation and 90°C high-humidity sterilization provide robust contamination control for repeated chamber hygiene routines.
Trade-offs
- Power supply constraint: Requires AC 220 V, 50 Hz power supply, which may not be compatible with 110 V or 60 Hz lab infrastructure.
- Limited ambient temperature range: Operates only within +5 to +30 °C ambient temperature, restricting placement in unconditioned or high-temperature lab environments.