155 L CO2 Incubator AF-CO2C-155 ATOMFAIR®

$7,300.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

155 L CO2 incubator with IR sensing, 0 to 20% CO2 control, 90 °C sterilization, RT+3 to 55 °C, 3 shelves. ATOMFAIR®

SKU: AF-LE-E-CRHC-0155-15CR
Category:
Brands:

155 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
Product Overview

155 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control is designed for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows. Infrared CO2 sensing, 90 °C sterilization, high humidity cell culture support, and recovery-focused chamber design. The configuration provides RT + 3 to 55 °C, 750 W rated power, a working chamber of 480 × 530 × 610 mm (W × D × H), and external dimensions of 670 × 767 × 880 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2C-155
Product Family CO2 Incubator, Professional Cell Culture Series
Configuration 155 L
Rated Operating Power 750 W
Working Chamber Size 480 × 530 × 610 mm (W × D × H)
Overall Dimensions 670 × 767 × 880 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Sterilization 90 °C high-temperature and high-humidity sterilization
Optional Accessories and Functions HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable
Performance Features
  • Infrared CO2 sensing supports stable CO2 control and faster recovery in frequent door-opening workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • A 90 °C high-temperature and high-humidity sterilization cycle can treat the chamber and internal components. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Microbial filtration at the CO2 inlet and optional HEPA filtration support cleaner chamber conditions. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Door heating reduces condensation on the inner glass door and supports cleaner cell culture operation. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • An LCD display, stackable cabinet design, and data export options support day-to-day laboratory use. This makes real-time parameter review and routine operation easier in cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Alarms cover over-temperature, CO2 deviation, and prolonged door opening according to the product design. This helps operators identify abnormal conditions during unattended or extended cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 670 × 767 × 880 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires an ambient temperature range of +5 to +30 °C and a stable AC 220 V, 50 Hz power supply. The 90 °C sterilization cycle and high-humidity operation necessitate chamber and sensor access for cleaning and inspection.

  • Temperature Recovery Constraint: Temperature recovery to 37 °C after a 30-second door opening must not exceed 8 minutes.
  • CO2 Recovery Constraint: CO2 recovery to 5% after a 30-second door opening must not exceed 3 minutes.
  • Sterilization Cycle Constraint: The 90 °C high-temperature and high-humidity sterilization cycle requires the chamber to be empty and all internal components accessible.
  • Installation Space Constraint: Installation requires a clear space accommodating the 670 × 767 × 880 mm external dimensions and accessible chamber, sensors, shelves, filters, doors, test ports, and control interfaces.

Confirm the installation space and power supply before unpacking. Perform the 90 °C sterilization cycle prior to first use to ensure chamber cleanliness.

Required Equipment: AC 220 V, 50 Hz power supply, Suitable lifting equipment for transport

  1. Verify Installation Space
    Confirm the available space accommodates the 670 × 767 × 880 mm external dimensions and provides access to all chamber components.
  2. Connect Power Supply
    Connect the incubator to a stable AC 220 V, 50 Hz power outlet with the correct rated capacity.
  3. Perform Sterilization Cycle
    Initiate the 90 °C high-temperature and high-humidity sterilization cycle with the chamber empty to decontaminate internal surfaces.
  4. Set Temperature and CO2 Parameters
    Set the desired temperature within RT + 3 to 55 °C and CO2 concentration within 0 to 20% using the LCD display and PID controller.
  5. Load Samples and Close Door
    Place culture vessels on the shelves, ensuring even spacing for airflow, and close the inner glass and outer doors securely.
  6. Monitor Recovery After Door Opening
    Verify that temperature recovers to setpoint within 8 minutes and CO2 recovers to setpoint within 3 minutes after a door opening.
  7. Enable Alarm Monitoring
    Confirm that over-temperature, CO2 deviation, and prolonged door opening alarms are active for unattended operation.

What is the temperature uniformity and stability of the Atomfair 155 L CO2 incubator at 37°C?

The temperature uniformity is ±0.3°C at 37°C, and temperature stability is ±0.1°C, as specified in the technical specifications for the 155 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control.

What optional communication and data export options are available for this incubator?

Optional accessories include a printer and a communication interface for data export, along with an LCD display for real-time parameter review. These options support laboratory data logging and integration with external systems.

What are the external dimensions and power requirements for installing this 155 L CO2 incubator?

The external dimensions are 670 × 767 × 880 mm (W × D × H), and it requires AC 220 V, 50 Hz power supply with a rated power of 750 W. Adequate space and power should be confirmed before installation.

The 155 L CO2 Incubator (AF-CO2C-155) provides infrared CO2 sensing with ±0.1% accuracy and rapid recovery, plus 90°C sterilization, making it suitable for contamination-sensitive cell culture. However, it requires a controlled ambient temperature (5–30°C) and relies on passive humidity without active control.

Positive

  • Infrared CO2 Sensing with Rapid Recovery: Infrared sensor provides ±0.1% CO2 control accuracy and recovers to 5% within 3 minutes after a 30-second door opening, supporting stable conditions during frequent access.
  • 90°C High-Temperature Sterilization: A 90°C high-humidity sterilization cycle treats the chamber and internal components, enabling reliable decontamination between experiments.

Trade-offs

  • Ambient Temperature Range Constraint: The incubator requires a working ambient temperature of +5 to +30°C, which may necessitate laboratory HVAC adjustment or location planning.
  • Passive Humidity Without Active Control: Relative humidity is achieved by natural evaporation and is not actively controlled; humidity display is an optional accessory, limiting precise humidity management.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).