Description
1435L-6 Anti-Static Extreme-Low-Humidity (1%-3% RH) Dry CabinetsDry storage cabinet, extreme-low-humidity control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This cabinet maintains an internal relative humidity of 1%-3% RH for storage of highly moisture-sensitive components. It requires upright transport, level installation, sealed door closure, and stable power supply to prevent moisture damage and ensure reliable operation.
- Transport Constraint: Transport the cabinet only in an upright orientation with reinforced outer packaging to avoid structural damage and seal displacement.
- Installation Constraint: After installation, verify that the cabinet is placed on a level surface, all door seals are intact, and the power supply is stable before loading moisture-sensitive materials.
- Operational Constraint: Maintain cabinet door closed during normal operation to prevent ambient moisture ingress and ensure stable humidity within the 1%-3% RH range.
- Validation Constraint: For extreme-low-humidity applications, validate the storage process under actual conditions and consider integrating a nitrogen purge system or over-humidity alarm for process-critical materials.
Follow these steps to transport the cabinet, prepare it for operation, and load moisture-sensitive materials. Proper setup ensures stable humidity control and prevents damage to stored items.
Required Equipment: Suitable lifting equipment
- Transport Cabinet
Transport the cabinet upright using suitable lifting equipment and reinforced outer protection. - Position Cabinet
Place the cabinet on a level surface and confirm stable placement before removing packaging. - Connect Power
Connect the cabinet to a stable power supply and verify that the LCD display activates. - Set Humidity Level
Set the desired humidity level via the microcomputer control panel; the set point is retained after power interruption. - Load Materials
Close the cabinet door securely and load moisture-sensitive materials onto the adjustable shelves, ensuring even distribution for uniform air circulation.
How reliably can the Atomfair DC-Series extreme-low-humidity cabinet maintain 1-3% RH given the Honeywell sensor's ±3% RH accuracy?
The Honeywell temperature and humidity sensor has a stated accuracy of ±3% RH with 0.3% annual drift, so at a set point of 2% RH the actual chamber humidity could theoretically fall between 0% and 5% RH. This offset must be considered for critical processes; users should validate with a calibrated external reference and may add the optional over-humidity alarm for tighter monitoring.
Is the anti-static cabinet body sufficient for storing ESD-sensitive components in a semiconductor cleanroom?
The cabinet features an anti-static powder-coated steel body designed to reduce static accumulation, and the application scope explicitly includes semiconductor cleanrooms and SMT component rooms. However, the product description does not specify a dedicated grounding point or ESD compliance certification, so users handling highly ESD-sensitive devices should confirm grounding pathways and may opt for the premium stainless-steel body in corrosive or stricter environments.
What are the critical installation and handling requirements for the 1435L-6 dry cabinet to ensure proper sealing and operation?
The cabinet must be transported upright with reinforced outer protection and moved with suitable lifting equipment given its 1435L volume. After installation, confirm level placement, door sealing, shelf loading and stable power before storing materials. The door must be kept closed during normal use and ambient exposure of sensitive materials minimized to maintain the 1%-3% RH target.
The AF-DC1435DF-6 provides extreme-low-humidity storage at 1%-3% RH using an automatic electronic dehumidification system without disposable desiccants, making it suitable for highly moisture-sensitive components and materials; however, its large volume requires careful transport and level installation, and ultra-low humidity performance should be validated before critical use.
Positive
- Extreme-low humidity control: Maintains 1%-3% RH for highly moisture-sensitive electronics, optical components, and process materials, preventing oxidation, solderability loss, and micro-structural degradation.
- No disposable desiccant required: Automatic electronic dehumidification module eliminates consumable desiccant replacement, supporting continuous low-maintenance operation.
Trade-offs
- Large cabinet handling requirements: The 1435L cabinet requires reinforced outer protection during transport, upright orientation, and suitable lifting equipment; after installation, level placement and door seal confirmation are necessary before use.
- Humidity validation needed for critical use: For extreme-low humidity storage, the manufacturer recommends validating performance before formal production use and considering optional nitrogen purge or alarm systems when process risk is high.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).