160L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet BodyResearch-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The cabinet requires a stable indoor surface, a continuous nitrogen supply (0-50 L/min), and power connection for automatic control. Proper sealing of the magnetic door and even distribution of stored materials are necessary to maintain the specified humidity range and prevent damage.
- Stable Installation: Position the cabinet on a level, stable surface to ensure door alignment and sealing integrity.
- Nitrogen Supply: Verify a stable nitrogen supply with flow adjustment between 0 and 50 L/min before operation.
- Even Loading: Distribute stored items evenly across the three adjustable shelves to avoid exceeding the shelf-load capacity.
- Door Sealing: Keep the cabinet door closed during normal use and inspect the magnetic seal regularly for airtightness.
- Utility Conditions: Confirm power and gas connections are correctly configured before formal use of the cabinet.
Follow these steps to install, configure, and begin using the nitrogen cabinet for controlled storage of oxidation-sensitive materials. Proper setup ensures accurate humidity control and extends the lifespan of stored items.
- Position the cabinet
Position the cabinet on a stable level surface near a nitrogen supply source and power outlet. - Connect nitrogen supply
Connect the nitrogen supply line to the cabinet's flow control inlet and set the flow rate between 0 and 50 L/min. - Power on the cabinet
Plug the cabinet into a suitable power source and turn on the automatic control system. - Verify system status
Verify that the temperature and humidity display shows readings within the expected range and the door seals properly. - Load materials
Load oxidation-sensitive materials evenly onto the adjustable shelves, ensuring the door can close fully.
What is the practical impact of the ±3% RH humidity indication accuracy on maintaining ultra-low humidity conditions near 1% RH for oxidation-sensitive materials?
At a 1% RH setpoint, the ±3% RH accuracy means the actual chamber humidity could range from 0% to 4% RH. This tolerance is acceptable for general oxidation-sensitive storage, but applications requiring tighter control (e.g., below 2% RH) may benefit from the optional electronic dehumidification module to reduce reliance on nitrogen purge alone.
Can the over-humidity alarm be integrated with external building management systems or is it limited to local alerts?
The standard over-humidity alarm provides local indication only. For remote monitoring or integration with external management systems, the optional RS485 communication interface is required, which enables PC-side status logging and alarm notification. The product description does not specify the alarm's electrical output type, so direct BMS integration may require additional adaptation.
What nitrogen supply specifications are needed to reliably achieve the full 0-50 L/min flow adjustment range?
The product description does not specify required nitrogen purity or supply pressure. For reliable operation up to 50 L/min, a clean, dry nitrogen source with a pressure regulator capable of maintaining stable flow is necessary. Users should verify supply compatibility with the manufacturer, as inadequate pressure or impurities may compromise humidity control and cabinet atmosphere stability.
This 160L anti-oxidation nitrogen cabinet with anti-static body provides a controlled low-humidity nitrogen atmosphere for oxidation- and moisture-sensitive materials, featuring Honeywell sensor accuracy and adjustable nitrogen flow, but requires external nitrogen supply and careful environmental planning.
Positive
- Precision humidity sensing with low drift: Honeywell temperature and humidity sensor provides ±3% RH indication accuracy and only 0.3% annual drift, ensuring reliable long-term humidity control for stored materials.
- Adjustable nitrogen flow for atmosphere control: 0-50 L/min nitrogen flow adjustment combined with fully automatic computer control allows precise management of cabinet atmosphere, reducing oxidation and moisture absorption.
Trade-offs
- Requires external nitrogen supply: Operation depends on a stable external nitrogen gas supply; users must verify gas-supply conditions before use, adding infrastructure and ongoing consumable costs.
- Standard body not corrosion-resistant: The standard anti-static coating on galvanized steel may not be suitable for corrosive environments; a stainless steel upgrade is optional and requires additional procurement.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).