ATOMFAIR® EB220G-0.1MG-03 HIGH-PRECISION ANALYTICAL BALANCE (Lab Basic Grade | Auto Zero-Tracking Calibration)LABORATORY INSTRUMENT GRADE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The balance requires a stable, vibration-free environment and must be leveled before use. Pre-warming and activation of the transport lock are mandatory for accurate operation and safe relocation.
- Leveling Requirement: Place the balance on an anti-vibration stone table and adjust the leveling feet until the built-in bubble level indicates level.
- Pre-Warming Protocol: Connect the balance to power and allow it to warm up for the time specified in the manufacturer's manual before any weighing.
- Transport Lock Mechanism: Engage the mechanical glass door transport lock before moving the balance to prevent damage to the weighing mechanism.
- Draft Shield Usage: Keep the four-sided glass draft shield and aluminum backplate closed during measurements to minimize air current interference.
- Zero-Tracking Calibration: Use the automatic zero-tracking calibration function to compensate for minor environmental drift during long weighing sessions.
Proper setup ensures accurate measurements and longevity of the instrument. Follow these steps to prepare the balance for routine weighing tasks.
Required Equipment: Anti-vibration stone table, Leveling feet adjustment tool (if required), Power supply and timer, Glass door transport lock mechanism
- Level the balance
Position the balance on an anti-vibration stone table and adjust the leveling feet until the bubble level is centered. - Pre-warm the instrument
Connect the balance to the power source and allow it to warm up for the manufacturer-recommended duration before use. - Perform zero calibration
Press the tare or zero button to initiate automatic zero-tracking calibration after the warm-up period. - Secure the draft shield
Close all glass doors and the aluminum backplate to create a stable internal chamber free from air currents. - Engage transport lock before moving
Activate the mechanical glass door transport lock whenever the balance needs to be relocated to prevent internal damage.
How does the EB220G-0.1MG-03 maintain ±0.1 mg repeatability at 220 g capacity without active temperature compensation?
The balance achieves ±0.1 mg repeatability through automatic zero-tracking calibration combined with a solid full-aluminum anti-vibration base and 4-level shock absorption adaptation, which actively suppresses ambient low-frequency vibrations. The four-sided glass draft shield with aluminum alloy backplate further minimizes airflow interference, ensuring stable readings in general laboratory environments without requiring active temperature compensation.
What are the practical constraints for using the built-in under-hook weighing setup on the EB220G-0.1MG-03?
The internal below-balance underhook setup supports density determination and magnetic measurements, but requires the balance to be completely leveled on an anti-vibration stone table and pre-warmed according to specifications before operation. The draft shield doors must remain closed during measurement to maintain the airflow-blocking integrity of the four-sided transparent glass enclosure and aluminum alloy backplate.
What infrastructure and handling procedures are required to achieve the specified 0.1 mg readability on the EB220G-0.1MG-03?
The balance must be placed on an anti-vibration stone table and fully leveled before use. Pre-warming according to specifications is mandatory to stabilize internal electronics. The mechanical glass door transport lock must be engaged whenever the device is moved to prevent damage to the weighing mechanism, and the display screen protective dust guard should remain in place when not in use.
The ATOMFAIR EB220G-0.1MG-03 analytical balance provides 220 g capacity with 0.1 mg readability and ±0.1 mg repeatability, featuring automatic zero-tracking calibration, vibration suppression base, and advanced draft shield for reliable trace quantitative analysis in basic lab environments.
Positive
- Vibration Suppression Architecture: Solid full-aluminum base with 4-level shock absorption adaptation effectively suppresses ambient low-frequency vibration for stable readings in general lab environments.
- Advanced Draft Shield Design: Four-sided transparent glass draft shield with aluminum alloy backplate and under-pan airflow breeze shield minimizes air current interference for precise 0.1 mg weighing.
Trade-offs
- Requires Leveling and Pre-Warming: Must be completely leveled on an anti-vibration stone table and pre-warmed per specifications before operation to achieve rated accuracy.
- Transport Lock Activation Required: Glass door transport security mechanism must be enabled before moving the balance to prevent damage to the weighing mechanism.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).