ATOMFAIR® EB200G-1MG HIGH-PRECISION ELECTRONIC BALANCELABORATORY INSTRUMENT GRADE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The balance requires a vibration-free, level surface and a draft-free environment to maintain ±1 mg repeatability and ±2 mg linearity. The glass draft shield and aluminum base suppress airflow and low-frequency vibrations, but the device must be leveled and calibrated before each use.
- Vibration and Draft Sensitivity: Parasitic cross-currents and ambient vibrations degrade measurement accuracy, necessitating the use of the four-sided glass draft shield and solid aluminum base.
- Transport Lock Requirement: The mechanical transit security lock must be engaged before relocating the balance to prevent permanent structural cell degradation.
- Overload Protection: Automated diagnostic fault tracking and full-range tare thresholds guard against overload-induced sensor damage.
Level the balance on a vibration-free bench using the adjustable feet and built-in bubble level. Perform calibration using the light-touch keys after a 30-minute warm-up period.
Required Equipment: Adjustable leveling feet, Built-in bubble level
- Position the balance
Place the balance on a stable, vibration-free laboratory bench away from drafts and direct sunlight. - Level the device
Adjust the four leveling feet until the bubble in the built-in level is centered. - Power on and warm up
Connect the power supply and allow the balance to warm up for at least 30 minutes to stabilize internal electronics. - Perform calibration
Press the calibration key on the light-touch panel and follow the on-screen prompts using a certified calibration weight. - Verify repeatability
Place a test weight on the pan three times and confirm that readings fall within ±1 mg of each other.
What is the impact of the 1 mg readability on the EB200G-1MG's suitability for gravimetric analysis of solid-state electrolyte materials?
The 1 mg readability (0.001 g) with ±1 mg repeatability and ±2 mg linearity ensures sufficient precision for typical solid-state electrolyte precursor weighing (e.g., 0.1–10 g samples). The 200 g maximum capacity accommodates batch preparations, while the four-sided glass draft shield and aluminum alloy backplate minimize air currents that could affect microgram-level stability.
Can the EB200G-1MG be integrated with below-balance density measurement setups for solid-state electrolyte density determination?
Yes, the balance features a built-in underhook for dynamic below-balance density setups, enabling density measurements of solid samples via Archimedes principle. This is directly supported by the 'dynamic below-balance density setups' capability listed in the product's multi-functional research platform features.
What steps are required to ensure the balance's transport lock is properly engaged before relocation?
The EB200G-1MG includes a mechanical transit security lock on the glass door. Before moving, secure this lock to prevent permanent structural cell degradation. After relocation, the balance must be leveled and calibrated in a vibration-free environment prior to deployment, as stated in the operational notice.
The ATOMFAIR EB200G-1MG is a 200 g capacity analytical balance with 1 mg readability, featuring a four-sided glass draft shield and aluminum alloy base for environmental isolation, but requires a vibration-free leveled surface and transport lock engagement to prevent sensor damage.
Positive
- High precision 1 mg readability: With ±1 mg repeatability and ±2 mg linearity, this balance supports analytical chemistry and solid-state electrolyte processing requiring milligram-level accuracy.
- Advanced environmental isolation: The four-sided glass draft shield, aluminum alloy backplate, and under-pan breeze break block parasitic air currents, improving measurement stability in non-ideal lab conditions.
Trade-offs
- Requires vibration-free environment: The balance must be leveled and calibrated in a vibration-free location prior to use; the transport security lock must be engaged before any relocation to avoid permanent cell degradation.
- Limited to 200 g maximum capacity: With a 200 g max load, this balance is unsuitable for samples or containers exceeding this mass, constraining its application to smaller analytical workloads.