ATOMFAIR® EB60G-0.1MG-R DUAL-RANGE ANALYTICAL BALANCELABORATORY INSTRUMENT GRADE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The balance must be operated on a vibration-free stone table and pre-warmed prior to use. The glass door transport lock must be engaged before any movement to prevent damage to the weighing mechanism.
- Leveling requirement: The balance must be completely leveled on an anti-vibration stone table.
- Pre-warming requirement: The balance must be pre-warmed according to manufacturer specifications before operation.
- Transport lock requirement: The glass door transport lock must be activated before moving the device.
Proper initialization and handling of the balance ensure accurate measurements and prevent damage. Follow these steps before and during use.
Required Equipment: Anti-vibration stone table
- Level the balance
Level the balance on an anti-vibration stone table. - Pre-warm the balance
Pre-warm the balance according to the manufacturer's specifications before taking measurements. - Secure transport lock
Engage the glass door transport lock before moving the device to a different location.
How does the dual-range capability of the EB60G-0.1MG-R affect measurement precision across its two weighing ranges?
The EB60G-0.1MG-R offers two ranges: 60 g with 0.1 mg readability and 210 g with 1 mg readability. Repeatability is ±0.1 mg in the high-precision range and ±1 mg in the extended range, with linearity errors of ±0.2 mg and ±2 mg respectively. This allows users to select the optimal precision for sample mass without switching instruments.
What infrastructure is required to achieve stable operation for solid-state cell boundary validation with this analytical balance?
The balance must be placed on a completely leveled anti-vibration stone table and pre-warmed according to specifications before operation. Its vibration suppression architecture includes a solid full-aluminum base and 4-level anti-shock adaptation to eliminate ambient low-frequency vibrations, which is critical for trace quantitative chemistry and solid-state cell boundary validation.
How does the integrated glass draft shield and transport lock protect the balance during relocation and operation?
The four-sided transparent glass draft shield combined with an aluminum alloy backplate and under-pan breeze shield secures the analytical chamber from air currents. A mechanical glass door transport lock must be activated before moving the device to prevent damage. The display also has a protective dust guard, and automatic zero-tracking calibration ensures robust longevity.
The EB60G-0.1MG-R is a dual-range analytical balance offering 0.1 mg/1 mg readability across 60 g/210 g capacities, with vibration-dampening hardware and draft shielding suitable for trace chemistry and solid-state material validation. Users must account for anti-vibration table requirements and mandatory transport lock procedures.
Positive
- Dual-Range Precision Capability: Offers 0.1 mg readability at 60 g capacity and 1 mg readability at 210 g capacity, enabling both trace quantitative analysis and higher-capacity weighing in a single instrument.
- Vibration and Draft Suppression: Solid full-aluminum base and four-sided glass draft shield with under-pan airflow blocker isolate the weighing chamber from ambient low-frequency vibrations and air currents, critical for stable sub-milligram measurements.
Trade-offs
- Requires Specialized Setup: Must be placed on an anti-vibration stone table and pre-warmed per specifications before operation, adding infrastructure and preparation time for laboratory deployment.
- Transport Lock is Mandatory: The glass door transport lock must be engaged before moving the balance; failure to do so risks mechanical damage to the draft shield, limiting portability.