Description
160L Low-Humidity (10%-20% RH) Dry CabinetsDry storage cabinet, low-humidity control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The cabinet must be transported upright and installed on a level surface to ensure proper door sealing and humidity control. The door should remain closed during operation, and the ambient exposure of stored materials should be minimized to prevent humidity drift.
- Transportation Constraint: The cabinet must be transported upright with reinforced outer protection and suitable lifting equipment to avoid structural damage.
- Installation Constraint: The cabinet must be placed on a level surface, and door sealing, shelf loading, and power stability must be confirmed before use.
- Operational Constraint: The cabinet door must remain closed during normal operation to maintain the set humidity range of 10% to 20% RH.
- Sensor Accuracy Constraint: The Honeywell sensor exhibits a typical annual drift of 0.3% RH, requiring periodic recalibration to maintain ±3% RH accuracy.
- Ultra-low Humidity Validation: For ultra-low or extreme-low humidity applications, the storage process must be validated before formal production use, and nitrogen purge or alarm options are recommended.
Begin by transporting the cabinet upright to the installation site. After installation, confirm level placement, door sealing, and stable power before loading moisture-sensitive materials.
Required Equipment: Lifting or handling equipment
- Transport
Transport the cabinet upright with reinforced outer protection using suitable lifting or handling equipment. - Install
Place the cabinet on a level surface and ensure the door sealing gasket contacts evenly around the frame. - Verify
Confirm level placement, door sealing, shelf loading, and stable power connection before storing sensitive materials. - Load
Load moisture-sensitive materials onto the adjustable shelves, ensuring uniform air circulation and not overloading the shelves. - Operate
Keep the cabinet door closed during normal operation and minimize extended ambient exposure of stored materials. - Validate
Validate the storage process for ultra-low or extreme-low humidity applications before formal production use, considering nitrogen purge or alarm options.
How does the Honeywell sensor's ±3% RH accuracy and 0.3% annual drift affect long-term humidity stability in a 10%-20% RH cabinet?
The Honeywell sensor provides ±3% RH accuracy with only 0.3% annual drift, ensuring reliable measurement over extended periods. However, cumulative drift may gradually shift readings, potentially requiring recalibration or sensor replacement to maintain tight control within the 10%-20% RH set point. The cabinet's automatic electronic dehumidification module operates without disposable desiccants, but long-term stability depends on sensor accuracy to avoid deviation from the target range.
Can this 160L low-humidity cabinet be integrated with a nitrogen purge system for ultra-low humidity applications?
Yes, an optional nitrogen purge system is available for this cabinet, enabling accelerated dehumidification and inert-atmosphere management. The base model is configured for 10%-20% RH; for ultra-low (<10% RH) or extreme-low (<3% RH) applications, the nitrogen purge option or a different humidity grade model (C or D) is recommended. The cabinet's sealed construction with magnetic gaskets and tempered glass door supports nitrogen retention when the purge system is installed.
What are the critical handling and installation requirements for this 160L dry cabinet to ensure proper performance?
The cabinet must be transported upright with reinforced outer protection and moved using suitable lifting equipment due to its 160L volume. After installation, confirm level placement, door sealing, shelf loading, and stable power before storing sensitive materials. Keep the cabinet door closed during normal use to minimize ambient exposure; for ultra-low humidity applications, validate the storage process and consider optional nitrogen purge or over-humidity alarm systems.
The Atomfair AF-DC160B 160L dry cabinet provides reliable low-humidity storage at 10%-20% RH using automatic electronic dehumidification and a Honeywell sensor with ±3% RH accuracy, making it suitable for moisture-sensitive electronics and laboratory samples, though it requires careful handling during transport and installation and is not designed for sub-10% RH applications.
Positive
- Consumable-free dehumidification: Automatic electronic dehumidification module eliminates the need for disposable desiccant, reducing ongoing maintenance and consumable costs.
- High-accuracy Honeywell sensor: Integrated Honeywell temperature and humidity sensor delivers ±3% RH accuracy with only 0.3% annual drift, ensuring reliable long-term measurement for process control.
Trade-offs
- Handling and installation constraints: The cabinet must be transported upright with reinforced protection, and after installation, level placement, door sealing, shelf loading, and stable power must be verified before storing sensitive materials.
- Limited to 10%-20% RH range: This model is configured for low-humidity (10%-20% RH) only; materials requiring ultra-low (<10% RH) or extreme-low (<3% RH) conditions require a different model or optional nitrogen purge system.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).