70L Biochemical Incubator 0-50°C 500W LCD ATOMFAIR®

$950.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

70 L biochemical incubator with 0-50°C control, ±1°C accuracy, 500 W power, LCD timing to 9999 min, and stainless-steel chamber. Order now.

70L General Biochemical Incubator with 0-50°C Temperature Control Range
Research-grade laboratory product
Product Overview

70L General Biochemical Incubator with 0-50°C Temperature Control Range is designed for microbiology culture work, sample holding, routine incubation and steady low-temperature laboratory processing where clear control and stable cabinet conditions matter in daily use.

This 70 L model combines microcomputer temperature control, an LCD display, a stainless-steel working chamber, removable shelves and a magnetic door seal in a clean cabinet structure that supports repeatable operation and convenient observation during laboratory workflows.

The chamber size is 345 x 400 x 500 mm, the external size is 575 x 555 x 1180 mm, and the rated power is 500 W. The 0-50 C temperature control range supports bacteria and mold culture, microorganism preservation, water analysis, BOD-related work, plant cultivation and other temperature-managed laboratory tasks described for this product family.

The cabinet is intended for research institutes, university laboratories, public health work, pharmaceutical inspection, environmental analysis and other technical settings that need a practical incubator with straightforward daily operation, visible status display and an interior layout that is easy to organize and clean.

When the set temperature is below 10 C, ambient temperature should be below 26 C.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BI70-T50
Nominal Capacity 70 L
Effective Capacity 70 L
Temperature Control Range 0 to 50 C
Temperature Control Accuracy +/-1 C
Temperature Uniformity +/-2 C
Display Mode LCD display
Timing Range 0 to 9999 min
Power Supply AC 220 V, 50 Hz
Rated Power 500 W
Working Chamber Size 345 x 400 x 500 mm
Overall Dimensions 575 x 555 x 1180 mm
Net Weight 53.5 kg
Shelf Configuration 2 standard shelves
Chamber Material Stainless-steel working chamber
Exterior Finish Coated cabinet exterior
Ambient Condition Note When set temperature is below 10 C, ambient temperature should be below 26 C.
Performance Features
  • Microcomputer control with LCD display allows operators to view set temperature, current temperature and timing status directly, improving day-to-day monitoring efficiency.
  • PID temperature control helps reduce fluctuation during operation, which is useful for culture storage, incubation consistency and routine repeatability.
  • The 0-50 C temperature control range gives this model flexibility for low-temperature storage, constant-temperature holding and general biochemical incubation workflows.
  • The 70 L chamber size supports routine sample batches without making the cabinet unnecessarily large for standard benchside or floor-standing laboratory use.
  • Stainless-steel chamber construction supports cleanliness, corrosion resistance and easier interior maintenance after repeated laboratory use.
  • Removable shelves make it easier to adjust internal layout for bottles, flasks, culture containers and other routine laboratory items.
  • The magnetic door sealing structure improves closing convenience and chamber tightness, helping reduce unnecessary disturbance during operation.
  • The inner door structure and visual observation design help users check chamber conditions more conveniently while reducing frequent full-door opening.
  • Built-in timing from 0 to 9999 min supports scheduled operation and reduces the need for continuous manual supervision.
  • The circulation fan and air-duct structure described for this series help improve chamber temperature uniformity, which is beneficial for more consistent incubation conditions across the usable space.
  • Functions such as self-diagnosis, over-temperature limit support and power-failure memory help strengthen operational reliability in routine laboratory environments.
APPLICATION SCOPE: Suitable for bacteria and mold culture, microorganism preservation, BOD-related work, water analysis, plant cultivation, breeding tests, sample holding and other laboratory workflows that require controlled temperature management in research, teaching, inspection and technical support environments.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging to improve cushioning, stability and handling protection during storage, transfer and delivery. Additional reinforcement measures can be arranged according to order quantity and transport conditions.
IMPORTANT NOTICE: Please confirm nominal capacity, installation size, power supply and required configuration before quotation. Freight is quoted separately and the listed price does not include freight. When the set temperature is below 10 C, ambient temperature should be below 26 C. If custom dimensions or special configuration are required, contact our technical sales team by e-mail.
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

The incubator must be operated in an ambient temperature below 26°C when the set temperature is below 10°C. It requires a 220V, 50Hz electrical supply and is rated at 500W power consumption.

  • Ambient Temperature Constraint: When the set temperature is below 10°C, the ambient temperature must be below 26°C.
  • Power Supply Requirement: The incubator requires a 220V, 50Hz AC power supply with a rated power of 500W.
  • Over-Temperature Protection: The device includes over-temperature protection to automatically limit heating if the temperature exceeds safe levels.

What is the temperature uniformity and accuracy of the 70L biochemical incubator at low set points like 4°C?

The incubator has a temperature control accuracy of ±1°C and uniformity of ±2°C across the chamber. However, when the set temperature is below 10°C, the ambient temperature must be below 26°C to maintain performance. The PID control and circulation fan help reduce fluctuation and improve uniformity.

Can this 70L incubator be used with a 110V power supply?

No, the incubator requires AC 220V, 50 Hz power supply as specified in the technical specifications. It has a rated power of 500 W. Users must confirm power supply compatibility before procurement.

What is the shelf configuration and interior material of the 70L biochemical incubator?

The incubator comes with 2 standard removable shelves and a stainless-steel working chamber for corrosion resistance and easy cleaning. The magnetic door seal and inner door design improve chamber tightness and allow visual observation without frequent full-door opening.

The Atomfair AF-BI70-T50 is a 70L general biochemical incubator with a 0-50°C temperature control range and ±1°C accuracy, featuring a stainless-steel chamber, PID regulation, and an LCD display for routine microbiology and BOD applications. Its operation requires ambient control below 26°C when set below 10°C, and the forced-air circulation system enhances uniformity but adds minor periodic noise.

Positive

  • Stainless-steel chamber for corrosion resistance: The 70 L working chamber is constructed from stainless steel, facilitating interior cleanliness, corrosion resistance, and easier maintenance after repeated exposure to biological samples and humidity.
  • Wide 0-50°C range with PID control: The temperature control range from 0 to 50°C combined with PID regulation and an LCD display enables flexible use for low-temperature storage, constant-temperature incubation, and BOD analysis with reduced fluctuation and improved repeatability.

Trade-offs

  • Ambient temperature constraint at low setpoints: When the set temperature is below 10°C, the ambient temperature must be below 26°C. This environmental dependency may require additional climate control in warmer labs to maintain stable low-temperature operation.
  • Moderate temperature uniformity tolerance: The specified temperature uniformity of ±2°C places a practical limit on applications requiring extremely tight spatial consistency, such as some cell culture or sensitive enzymatic assays, without supplementary calibration.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).