50L General Biochemical Incubator with 0-70°C Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
This incubator requires a stable AC 220V, 50Hz power supply and operates within a 0-70°C temperature range. When the set temperature is below 10°C, the ambient temperature must be maintained below 26°C to ensure proper function.
- Power Supply Requirement: The incubator must be connected to a grounded AC 220V, 50Hz power outlet to avoid electrical hazards and ensure stable operation.
- Temperature Range Limit: Operate the incubator only within the 0-70°C temperature control range to prevent damage to the unit or samples.
- Ambient Temperature Constraint: If the set temperature is below 10°C, the ambient temperature must be below 26°C to maintain accurate temperature control.
- Over-Temperature Protection: The built-in over-temperature limit support should remain active to prevent overheating and protect the contents.
- Chamber Maintenance: Clean the stainless steel chamber regularly with non-abrasive materials to maintain hygiene and corrosion resistance.
This incubator uses microcomputer PID control with an LCD display for temperature and timing. Follow these steps to set up and operate the unit safely for biochemical incubation.
Required Equipment: Removable shelves
- Position and Power
Place the incubator on a stable, level surface and connect the power cord to a grounded AC 220V, 50Hz outlet. - Set Temperature
Set the desired temperature using the microcomputer control panel, observing the LCD display for confirmation. - Set Timer
If using timed operation, set the timing range from 0 to 9999 minutes via the control interface. - Check Ambient Temperature
If the set temperature is below 10°C, verify that the ambient temperature is below 26°C to ensure accurate control. - Stabilize Chamber
Allow the chamber to stabilize for a few minutes after reaching the set temperature before loading samples. - Load Samples
Load samples onto the removable shelves, ensuring adequate spacing for air circulation. - Secure Door
Close the door securely to engage the magnetic seal and minimize temperature disturbance.
What is the temperature uniformity specification for the 50L biochemical incubator and how is it maintained?
The temperature uniformity is ±2°C across the 50 L working chamber. This is achieved through a circulation fan and air-duct structure that improve chamber temperature uniformity, as stated in the product description.
Can this incubator be used for BOD (Biochemical Oxygen Demand) testing?
Yes, the incubator supports BOD-related work as part of its application scope. However, when the set temperature is below 10°C, the ambient temperature must be below 26°C to maintain stable operation.
What are the ambient temperature requirements when operating the incubator below 10°C?
When the set temperature is below 10°C, the ambient temperature must be below 26°C. This condition is explicitly stated in the product specifications to ensure proper temperature control and avoid performance issues.
This 50L biochemical incubator offers a 0-70°C range with ±1°C control accuracy and stainless-steel chamber, suitable for microbiology and BOD applications. Its low-temperature operation below 10°C requires ambient conditions under 26°C, a critical installation constraint.
Positive
- Wide 0-70°C temperature range: Supports both low-temperature storage and standard incubation in a single unit, reducing the need for separate chilled and warm chambers.
- Stainless-steel chamber with magnetic seal: Corrosion-resistant interior and tight door seal improve cleanliness, reduce contamination risk, and minimize thermal disturbance during operation.
Trade-offs
- Ambient temperature limit at low setpoints: When set temperature is below 10°C, ambient must be below 26°C, requiring air-conditioned lab space for cold operation.
- Single voltage and frequency configuration: Rated for AC 220V, 50 Hz only, limiting direct deployment in 110V or 60 Hz laboratory infrastructure without a transformer or frequency converter.