500L Standard Mold Incubator, 0-60℃ Temperature Control Range
Research-grade laboratory product
Product Overview

500L Standard Mold Incubator, 0-60℃ Temperature Control Range is designed for mold and fungal culture, microorganism observation, constant-temperature storage, and routine environmental incubation. With a nominal capacity of 500 L and a temperature range of 0-60℃, it supports controlled handling of cultures, fungal samples, microorganisms, preserved materials, and other laboratory test loads.

The cabinet layout is defined by the chamber size is 670×720×1020mm, overall dimensions are 850×1100×1930mm, the standard shelf setup is 3 shelves, input power is 2250 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±1.0°C fluctuation control, ±1.5°C to ±2.5°C at 25°C temperature uniformity, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Applicable cabinet series use one-piece foamed insulation to reduce heat loss and support steadier temperature control. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-MI500-MJ50F: Digital display controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Mold Incubator
Nominal Capacity 500 L
Atomfair Models AF-MI500-MJ50F
Temperature Range 0-60℃
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±1.0°C
Temperature Uniformity ±1.5°C to ±2.5°C at 25°C
Input Power 2250 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 30°C
Chamber Size 670×720×1020mm
Overall Dimensions 850×1100×1930mm
Shelves 3 shelves
Timer 0 to 5999 min
Cabinet Insulation Foamed cabinet insulation
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Applicable cabinet series use one-piece foamed insulation to reduce heat loss and support steadier temperature control.
Controller Configuration AF-MI500-MJ50F: Digital display controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations; UV sterilization system, standard or optional depending on the selected mold configuration. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±1.0°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Temperature uniformity of ±1.5°C to ±2.5°C at 25°C helps reduce position-related differences inside the chamber, which is valuable when multiple vessels are loaded at once.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for mold cultivation, fungal observation, microorganism incubation, and constant-temperature storage where stable chamber conditions help support culture development and routine laboratory checks.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

Use constraints for this mold incubator cover the rated electrical supply, ambient operating temperature, and internal chamber cleaning. No chemical-compatibility or material-degradation limits are documented for this equipment.

  • Rated supply constraint: Connect the incubator only to an AC220V 50Hz power source sized for the stated 2250 W input load.
  • Ambient operating constraint: Maintain the installation room between +5°C and 30°C during incubator operation and storage.
  • Footprint and clearance constraint: Verify that the floor-standing installation footprint and access clearances match the stated overall dimensions before final placement.
  • Chamber cleaning constraint: Clean the mirror stainless-steel chamber at the rounded-corner transitions and removable shelf supports to reduce contamination between culture runs.
  • Configuration confirmation constraint: Confirm the exact configuration, accessory package, and custom chamber-size requirements with the supplier before ordering.

Initialize the incubator by verifying installation requirements, connecting the rated supply, preparing the chamber, and setting the controller. Confirm the final configuration and accessory package with the supplier before proceeding.

Required Equipment: AC220V 50Hz power source, Digital display controller

  1. Confirm installation requirements
    Confirm the exact configuration, installation footprint, and power supply requirements with the supplier before positioning the incubator.
  2. Position the incubator
    Position the incubator in a floor-standing location that accommodates the stated overall dimensions and operating clearances.
  3. Connect power
    Connect the incubator to an AC220V 50Hz power source that supports the rated 2250 W input load.
  4. Prepare the chamber
    Clean the mirror stainless-steel chamber using the rounded-corner transitions and removable shelf supports before loading culture materials.
  5. Set the controller
    Set the required temperature and timer values on the digital display controller for the planned incubation.
  6. Load the chamber
    Load flasks, bottles, trays, or routine test loads onto the adjustable shelf supports.
  7. Verify chamber stability
    Verify that the displayed chamber temperature remains stable before beginning the culture incubation.

What is the temperature fluctuation specification for the 500L mold incubator at high versus low temperature setpoints?

The temperature fluctuation is ±0.5°C at high temperatures and ±1.0°C at low temperatures, as specified in the product datasheet. This difference reflects the inherent challenge of maintaining tighter control near the lower end of the 0–60°C range.

Can the 500L mold incubator be integrated with external data logging systems for continuous temperature monitoring?

Yes, the incubator offers optional RS485 communication interface and USB data transfer for recording temperature changes. An embedded printer is also available as an accessory. These options allow integration with laboratory information systems or standalone data loggers, but must be specified at order time as they are not standard.

What are the electrical and ambient temperature requirements for installing the 500L mold incubator?

The incubator requires a 2250W power supply at AC220V 50Hz and an ambient temperature range of +5 to 30°C. The overall dimensions are 850×1100×1930mm, so adequate floor space and ventilation are necessary. Ensure the electrical circuit can handle the continuous load and that the room temperature stays within the specified range to maintain performance.

The AF-MI500-MJ50F 500L mold incubator provides a 0-60°C range with ±0.5°C fluctuation at higher temperatures, suitable for fungal culture and microorganism incubation, but its ±1.5–2.5°C uniformity at 25°C may introduce position-dependent variability under moderate loads.

Positive

  • Rounded-corner stainless steel chamber: Mirror-finish 304 stainless steel interior with rounded-corner transitions facilitates cleaning and reduces contamination risk during mold and fungal culture work.
  • Digital controller with 0.1°C resolution: Allows fine setpoint adjustment for routine cultivation and preservation, supporting method repeatability in microbial incubation protocols.

Trade-offs

  • Moderate temperature uniformity at 25°C: Uniformity ranges from ±1.5 to ±2.5°C at 25°C, which can cause position-dependent thermal gradients across the 500L chamber when multiple vessels are loaded.
  • Fixed 220V 50Hz electrical requirement: Operates on single-phase AC220V 50Hz only, requiring laboratory infrastructure compatibility; 2250W input may demand dedicated circuit planning.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).