500L Low-Temperature Incubator, -20-65℃ Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
The incubator must be operated within an ambient temperature range of 5°C to 35°C to maintain proper cooling performance. The electrical supply must be a dedicated AC220V 50Hz circuit capable of delivering 2550W with proper grounding.
- Ambient Temperature Constraint: The incubator must be operated within an ambient temperature range of 5°C to 35°C to avoid compressor stress and maintain temperature stability.
- Electrical Supply Requirement: The unit requires a dedicated AC220V 50Hz power supply with a minimum capacity of 2550W and proper grounding to prevent electrical hazards.
- Over-Temperature Protection: An independent over-temperature alarm system is available as an optional accessory to provide additional safety against temperature runaway.
Position the incubator on a level surface with sufficient clearance for ventilation and compressor airflow. Connect the power supply to a grounded AC220V 50Hz outlet and set the target temperature using the microcomputer controller.
Required Equipment: Microcomputer liquid-crystal temperature controller
- Position the incubator
Place the incubator on a level, stable surface with adequate clearance for ventilation and access to the control panel. - Connect power supply
Connect the power cord to a dedicated AC220V 50Hz outlet that can supply 2550W and ensure proper grounding. - Set target temperature
Turn on the main power and use the microcomputer controller to set the desired temperature within the -20 to 65°C range. - Allow chamber stabilization
Allow the chamber to stabilize to the set temperature and verify the temperature fluctuation is within the specified limits (high temp ±0.5°C, low temp ±1.0°C). - Load samples
Arrange the shelves as needed and load samples, ensuring airflow is not obstructed and the load does not exceed shelf capacity.
How does the temperature fluctuation differ between high and low temperature operation in the 500L low-temperature incubator?
The incubator specifies a temperature fluctuation of ±0.5°C at high temperatures and ±1.0°C at low temperatures. This means stability is tighter above ambient, while at sub-ambient setpoints the compressor cycling introduces slightly wider variation. Users should account for this when planning preservation or incubation protocols near -20°C.
Can the 500L low-temperature incubator be connected to external monitoring systems for data logging?
Yes, the incubator offers optional RS485 communication and USB data transfer interfaces for recording temperature changes. An embedded printer is also available as an accessory. These options allow integration with laboratory data management systems, but availability and lead time should be confirmed by email before ordering.
What are the electrical and environmental installation requirements for the 500L low-temperature incubator?
The incubator requires a AC220V 50Hz power supply with an input power of 2550W, so a dedicated circuit is recommended. The ambient temperature must be between +5°C and 35°C for proper operation. The overall dimensions are 850×1100×1930mm, requiring adequate floor space and clearance for ventilation.
The 500L Low-Temperature Incubator provides a -20 to 65°C range with 0.1°C resolution and ±0.5 to ±1.0°C fluctuation, enabling sub-ambient incubation, preservation, and stability testing, but requires a 2550 W AC220V 50Hz supply and ambient temperature control of +5 to 35°C for stable operation.
Positive
- Sub-ambient temperature capability: The -20 to 65°C range extends usability to low-temperature cultivation, sample preservation, and stability testing beyond standard incubator limits, providing controlled cooling for temperature-sensitive materials.
- Fine temperature resolution and fluctuation: A 0.1°C resolution with high-temp fluctuation of ±0.5°C and low-temp ±1.0°C supports repeatable setpoint control for routine incubation and preservation protocols in laboratory workflows.
Trade-offs
- High input power requirement: With a 2550 W input power and AC220V 50Hz supply, this unit demands a dedicated electrical circuit and compatible infrastructure, which may limit installation in facilities with standard outlet configurations.
- Ambient temperature dependency: Operation is restricted to an ambient temperature range of +5 to 35°C, requiring climate-controlled lab environments; deviations may compromise cooling performance or temperature stability.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).