500 L CO2 Incubator with IR Control 1450 W ATOMFAIR®

$14,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 500 L CO2 incubator with infrared sensing, 0–20% CO2 control, 90 °C sterilization, and 1450 W power for cell culture. Order now.

SKU: AF-LE-E-CRHC-0500-50CR
Category:
Brands:

500 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
Product Overview

500 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control is designed for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows. Infrared CO2 sensing, 90 °C sterilization, high humidity cell culture support, and recovery-focused chamber design. The configuration provides RT + 3 to 55 °C, 1450 W rated power, a working chamber of 700 × 650 × 1100 mm (W × D × H), and external dimensions of 880 × 860 × 1500 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2C-500
Product Family CO2 Incubator, Professional Cell Culture Series
Configuration 500 L
Rated Operating Power 1450 W
Working Chamber Size 700 × 650 × 1100 mm (W × D × H)
Overall Dimensions 880 × 860 × 1500 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Sterilization 90 °C high-temperature and high-humidity sterilization
Optional Accessories and Functions HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable
Performance Features
  • Infrared CO2 sensing supports stable CO2 control and faster recovery in frequent door-opening workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • A 90 °C high-temperature and high-humidity sterilization cycle can treat the chamber and internal components. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Microbial filtration at the CO2 inlet and optional HEPA filtration support cleaner chamber conditions. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Door heating reduces condensation on the inner glass door and supports cleaner cell culture operation. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • An LCD display, stackable cabinet design, and data export options support day-to-day laboratory use. This makes real-time parameter review and routine operation easier in cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Alarms cover over-temperature, CO2 deviation, and prolonged door opening according to the product design. This helps operators identify abnormal conditions during unattended or extended cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 880 × 860 × 1500 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The 500 L CO2 Incubator requires a stable AC 220 V, 50 Hz power supply and an ambient temperature range of +5 to +30 °C for reliable operation. Installation space must accommodate its 880 × 860 × 1500 mm external dimensions, and the unit must be kept upright during transport using suitable lifting equipment.

  • Power Supply Constraint: The incubator must be connected to a dedicated AC 220 V, 50 Hz power outlet with proper grounding.
  • Ambient Temperature Constraint: Operate the incubator only within an ambient temperature range of +5 to +30 °C to ensure stable temperature control.
  • Installation Space Constraint: Provide a clear installation area that accommodates the external dimensions of 880 × 860 × 1500 mm (W × D × H) with adequate clearance for ventilation and access.
  • Transport and Handling Constraint: Keep the packed incubator upright at all times and use suitable lifting equipment to prevent impact damage during transport.

These steps guide the installation, power connection, CO₂ supply setup, and initial sterilization of the incubator. Proper execution ensures safe operation and optimal cell culture conditions.

Required Equipment: Suitable lifting equipment, Gas regulator (optional accessory)

  1. Confirm Installation Site
    Confirm that the installation site meets the space and power supply requirements specified in the technical specifications.
  2. Unpack and Position
    Unpack the incubator and place it on a level, stable surface at the prepared location.
  3. Connect Power Supply
    Connect the incubator to the AC 220 V, 50 Hz power supply using the provided power cord.
  4. Connect CO₂ Supply
    Connect the CO₂ supply line to the gas inlet using an appropriate regulator.
  5. Set Operating Parameters
    Set the desired temperature and CO₂ concentration on the LCD controller.
  6. Initiate Sterilization Cycle
    Initiate a 90 °C high-temperature and high-humidity sterilization cycle to prepare the chamber for use.
  7. Verify Alarm Functions
    Verify that the over-temperature, CO₂ deviation, and door-open alarms are functional before loading samples.

How quickly does the 500 L CO2 incubator recover CO2 concentration after a door opening?

The incubator recovers to 5% CO2 within no more than 3 minutes after a 30-second door opening, enabled by infrared CO2 sensing and gas-jacket PID control. This rapid recovery supports stable conditions during frequent door openings in cell culture workflows.

What sterilization method does the ATOMFAIR 500 L CO2 incubator use, and is it compatible with sensitive sensors?

The incubator uses a 90 °C high-temperature and high-humidity sterilization cycle that treats the chamber and internal components. The process is designed to inactivate contaminants without damaging the infrared CO2 sensor or other components, ensuring reliable operation after each cycle.

What are the power supply and ambient temperature requirements for the 500 L CO2 incubator?

The incubator requires AC 220V, 50Hz power supply with a rated power of 1450W. It operates in ambient temperatures from +5 to +30°C. Ensure the installation location meets these specifications and provides adequate space for the 880 × 860 × 1500 mm external dimensions.

This 500 L gas-jacket CO2 incubator provides IR-based CO2 control with ±0.1% accuracy and rapid recovery after door openings, plus a 90 °C high-humidity sterilization cycle and optional HEPA filtration for contamination-sensitive cell culture. Installation requires AC 220 V/50 Hz power, +5 to +30 °C ambient conditions, and 880 × 860 × 1500 mm floor space.

Positive

  • IR CO2 sensing with rapid recovery: Infrared CO2 control maintains ±0.1% accuracy and restores 5% CO2 within 3 minutes after a 30-second door opening, supporting frequent-access cell culture workflows.
  • 90 °C sterilization and inlet filtration: A 90 °C high-temperature, high-humidity sterilization cycle treats the chamber and internal components, while CO2 inlet microbial filtration and optional HEPA filtration help maintain cleaner chamber conditions.

Trade-offs

  • Fixed 220 V/50 Hz power requirement: The incubator is specified for AC 220 V, 50 Hz at 1450 W rated power; laboratory electrical infrastructure must be confirmed as compatible before installation.
  • Site and ambient prerequisites: External dimensions are 880 × 860 × 1500 mm, operating ambient must remain within +5 to +30 °C, and chamber, sensors, shelves, filters, doors, and test ports must stay accessible for routine cleaning and inspection.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).