240L `Vertical Electric Forced-Air Drying Oven`
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For capacity selection, accessory matching, voltage confirmation or other specification review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The oven must be connected to a power supply matching the configured voltage and must be placed in an environment with ambient temperature between 5°C and 40°C to prevent overheating. The chamber should not be used to process flammable or explosive materials due to the high operating temperature range up to 250°C.
- Voltage configuration: Confirm that the supply voltage matches the oven's configured voltage before connection to avoid electrical damage.
- Ambient temperature requirement: Operate the oven only within an ambient temperature range of 5°C to 40°C to ensure stable performance and prevent overheating of internal components.
- Material compatibility: Do not place flammable, explosive, or corrosive materials inside the chamber to avoid fire or chemical hazard.
- Ventilation clearance: Ensure adequate clearance around the oven for airflow to maintain proper forced-air circulation and prevent overheating.
The oven is designed for routine laboratory drying and heating tasks. Follow these steps to ensure safe and effective operation.
Required Equipment: Removable shelves, Power supply cable
- Verify power supply
Confirm that the power supply voltage matches the oven's configured voltage specification before plugging in the unit. - Position the oven
Place the oven on a stable, level surface with adequate clearance around all sides for ventilation. - Set temperature and timer
Use the control panel to set the desired temperature (RT+10°C to 250°C) and optional timer (1 to 9999 minutes) as needed. - Preheat the chamber
Allow the oven to preheat until the temperature stabilizes, indicated by the stability specification of ≤0.5°C. - Load samples
Place samples or glassware onto the removable shelves, ensuring proper spacing for airflow and avoiding overloading. - Monitor during operation
Observe the chamber condition through the viewing window without opening the door to maintain temperature uniformity. - Shut down and cool
Turn off the oven after the cycle completes and allow the chamber to cool to room temperature before opening the door.
How does the forced-air circulation design affect temperature uniformity in the 240L chamber?
The forced-air drying structure improves hot-air circulation inside the chamber, contributing to a temperature uniformity of ≤2.0% across the 240 L working space. This helps maintain consistent heating conditions for batch sample handling and routine drying tasks, supporting repeatable thermal processing.
Can this oven be integrated with external data logging or monitoring systems?
Yes, the oven offers an optional RS485 communication interface for printer or PC connection and temperature monitoring. Additionally, optional multi-point temperature recorder and programmable temperature controller with up to 99 segments x 99 program groups are available for extended configuration and data logging.
What are the power supply and installation requirements for this 240L drying oven?
The oven has a rated power of 2100 W and standard supply voltage of 220 V, which can be adjusted according to specific regional requirements. The unit weighs 90 kg with outer dimensions 640(W) x 780(D) x 1060(H) mm, requiring adequate bench or floor space and appropriate electrical infrastructure. Ambient operating temperature should be between 5 and 40°C.
This 240 L vertical electric blast drying oven provides forced-air circulation with 0.1 °C resolution, ≤0.5 °C stability, and ≤2.0% uniformity across its RT+10 to 250 °C range, making it suitable for routine glassware drying, sample conditioning, and batch heat treatment in laboratory or pilot settings. Operational planning must account for the ambient-dependent lower temperature limit, the need to confirm supply voltage before installation, and the 90 kg unit weight during handling and placement.
Positive
- Forced-air circulation with uniform heating: The forced-air drying design and ≤2.0% temperature uniformity support consistent heated-air conditions throughout the 240 L chamber for routine drying and batch thermal processing.
- Fine setpoint resolution and timed operation: A 0.1 °C resolution, ≤0.5 °C temperature stability, and 1–9999 min timing range enable repeatable scheduled heating cycles for daily laboratory workflows.
Trade-offs
- Ambient-dependent lower temperature limit: The usable range begins at RT+10 °C and the specified ambient operating range is 5–40 °C, so low-temperature drying or below-ambient conditioning is not supported.
- Voltage confirmation and heavy-unit handling: The standard 220 V/2100 W configuration is adjustable by request, but supply voltage must be confirmed before quotation, and the 90 kg gross weight requires planning for installation and transport handling.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.